PL EN


Preferences help
enabled [disable] Abstract
Number of results
Journal
2013 | 11 | 9 | 1554-1561
Article title

Potentiometric cholesterol biosensing application of graphene electrode with stabilized polymeric lipid membrane

Content
Title variants
Languages of publication
EN
Abstracts
EN
Abstract A novel potentiometric cholesterol biosensor has been fabricated through the immobilization of the stabilized polymeric lipid membrane onto graphene electrode. The stabilized polymeric lipid membrane is composed of cholesterol oxidase enzyme and polymerization mixture; which holds paramount influence on the properties of the cholesterol biosensor. The presented biosensor reveals an appreciable reproducibility, good selectivity and high sensing capability with a linear slope curve of ∼64 mV per decade. The strong biocompatibility among stabilized polymeric lipid membranes and human biofluids provides the possibility to use for real blood samples and other biological applications. Graphical abstract [...]
Publisher
Journal
Year
Volume
11
Issue
9
Pages
1554-1561
Physical description
Dates
published
1 - 9 - 2013
online
29 - 6 - 2013
References
  • [1] E. Ikonen, Nat. Rev. Mol. Cell Biol. 9, 125 (2008) http://dx.doi.org/10.1038/nrm2336[Crossref]
  • [2] F.R. Maxfield, I. Tabas, Nature 438 612, (2005) http://dx.doi.org/10.1038/nature04399[Crossref]
  • [3] M.Q. Israr, J.R. Sadaf, O. Nur, M. Willander, S. Salman, B. Danielsson, Appl. Phys. Lett. 98(25), 253705 (2011) http://dx.doi.org/10.1063/1.3599583[Crossref]
  • [4] E. Tamiya, Y. Sugiura, A. Akiyama, I. Karube, Ann. N. Y. Acad. Sci. 613, 396 (1990) http://dx.doi.org/10.1111/j.1749-6632.1990.tb18185.x[Crossref]
  • [5] V. Rajesh, W. Bisht, W. Takashima, K. Kaneto, Biomaterials 26(17), 3683 (2005) http://dx.doi.org/10.1016/j.biomaterials.2004.09.024[Crossref]
  • [6] S.P. Singh, A. Chaubey, B.D. Malhotra, Anal. Chim. Acta 502, 229 (2004) http://dx.doi.org/10.1016/j.aca.2003.09.064[Crossref]
  • [7] H.Y. Wang, S.L. Mu, Sens. Actuators B: Chem. 56, 22 (1999) http://dx.doi.org/10.1016/S0925-4005(99)00025-8[Crossref]
  • [8] J. Janata, M. Josowicz, D.M. DeVaney, Anal. Chem. 66, 207R (1994) http://dx.doi.org/10.1021/ac00084a010[Crossref]
  • [9] D.P. Nikolelis, D.A. Drivelos, M.G. Simantiraki, S. Koinis, Anal. Chem. 76(8), 2174 (2004) http://dx.doi.org/10.1021/ac0499470[Crossref]
  • [10] D.P. Nikolelis, G. Theoharis, Bioelectrochem. 59(1), 107 (2003) http://dx.doi.org/10.1016/S1567-5394(03)00009-4[Crossref]
  • [11] D.P. Nikolelis, M.G. Simantiraki, C.G. Siontorou, T. Toth, Anal. Chim. Acta 537, 169 (2005) http://dx.doi.org/10.1016/j.aca.2004.12.086[Crossref]
  • [12] D.P. Nikolelis, G. Raftopoulou, G.-P. Nikoleli, M. Simantiraki, Electroanalysis 18, 2467 (2006) http://dx.doi.org/10.1002/elan.200603702[Crossref]
  • [13] D.P. Nikolelis, M. Mitrokosta, Biosens. & Bioelectr. 17, 565 (2002) http://dx.doi.org/10.1016/S0956-5663(02)00017-9[Crossref]
  • [14] D.P. Nikolelis, C.G. Siontorou, Anal. Chem. 67(5), 936 (1995) http://dx.doi.org/10.1021/ac00101a022[Crossref]
  • [15] D.P. Nikolelis, T. Hianik, G.-P. Nikoleli, Electroanalysis 22(23), 2747 (2010) http://dx.doi.org/10.1002/elan.201000420[Crossref]
  • [16] D.P. Nikolelis, G. Raftopoulou, P. Chatzigeorgiou, G.-P. Nikoleli, K. Viras, Sens. Actuators B 130, 577 (2008) http://dx.doi.org/10.1016/j.snb.2007.10.011[Crossref]
  • [17] A.C. Ferrari, J.C. Meyer, V. Scardaci, C. Casiraghi, M. Lazzeri, F. Mauri, S. Piscanec, D. Jiang, K.S. Novoselov, S. Roth, A.K. Geim, Phys. Rev. Lett. 97, 187401 (2006) http://dx.doi.org/10.1103/PhysRevLett.97.187401[Crossref]
  • [18] Y. Hernandez, V. Nicolosi, M. Lotya, F.M. Blighe, Z. Sun, S. De, I.T. McGovern, B. Holland, M. Byrne, Y.K. Gun’Ko, J.J. Boland, P. Niraj, G. Duesberg, S. Krishnamurthy, R. Goodhue, J. Hutchison, V. Scardaci, A.C. Ferrari, J.N. Coleman, Nat. Nanotechnol. 3, 563 (2008) http://dx.doi.org/10.1038/nnano.2008.215[Crossref]
  • [19] M.A. Pimenta, G. Dresselhaus, M.S. Dresselhaus, L.G. Cancado, A. Jorio, R. Saito, Phys. Chem. Chem. Phys. 9, 1276 (2007) http://dx.doi.org/10.1039/b613962k[Crossref]
  • [20] G.E. Romanos, V. Likodimos, R.R.N. Marques, T.A. Steriotis, S.K. Papageorgiou, J.L. Faria, J.L. Figueiredo, A.M.T. Silva, P. Falaras, J. Phys. Chem. C 115, 8534 (2011) http://dx.doi.org/10.1021/jp200464d[Crossref]
  • [21] L. Charpentier, I.E. Murr, Anal. Chim. Acta. 318, 89 (1995) http://dx.doi.org/10.1016/0003-2670(95)00311-8[Crossref]
  • [22] A. L. Gopalan, K.-P. Lee, D. Ragupathy, Biosens. Bioelectron. 24(7), 2211, (2009). http://dx.doi.org/10.1016/j.bios.2008.11.034[Crossref]
  • [23] B. Ivanyi, E. Kemeny, E. Szederkenyi, F. Marofka, P. Szenohradszky, Mod Pathol 14(12), 1200 (2001) http://dx.doi.org/10.1038/modpathol.3880461[Crossref]
  • [24] A. Townshed, (Ed.), Encyclopedia of Analytical Chemistry (Academic Press Limited, London, 1995) Vol. 4, p. 2520 and Vol. 9, p. 5
  • [25] M. K. Ram, P. Bertoncello, H. Ding, S. Paddeu, C. Nicolini, Biosens. Bioelectron. 16, 849 (2001) http://dx.doi.org/10.1016/S0956-5663(01)00208-1[Crossref]
  • [26] G. Li, J.M. Liao, G.Q. Hu, N.Z. Ma, P.J. Wu, Biosens. Bioelectron. 20, 2140 (2005) http://dx.doi.org/10.1016/j.bios.2004.09.005[Crossref]
  • [27] A. Kumar Basu, P. Chattopadhyay, U. Roychoudhuri, R. Chakraborty, Bioelectrochemistry 70, 375 (2007) http://dx.doi.org/10.1016/j.bioelechem.2006.05.006[Crossref]
  • [28] G.-P. Nikoleli, M.Q. Israr, N. Tzamtzis, D.P. Nikolelis, M. Willander, N. Psaroudakis, Electroanalysis 24(6), 1285 (2012) http://dx.doi.org/10.1002/elan.201200104[Crossref]
Document Type
Publication order reference
YADDA identifier
bwmeta1.element.-psjd-doi-10_2478_s11532-013-0285-5
Identifiers
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.