EN
Five different columns (two silica, two cyanopropyl and one diol) were investigated in hydrophilic interaction liquid chromatography (HILIC). For the assessment of columns behavior in HILIC mode, six basic drugs (lamotrigine, thioridazine, clozapine, chlorpheniramine, pheniramine and sulpiride) were chosen. The assessment of the influence of the concentration of organic modifier on analytes’ retention on each column was provided by fitting the retention data into theoretical models. Utilizing the statistical analysis, the selection of the model that provides better prediction of the retention behavior was enabled. Dual RP-HILIC mechanism was suggested on cyanopropyl and diol columns, therefore the transition points between the two mechanisms on these columns were calculated. Furthermore, in order to investigate the impact of three factors simultaneously on the retention behavior of the analyzed substances on Betasil Silica column, chemometrically-aided empirical models were built. The experiments were conducted according to the matrix of Box-Behnken design and on the basis of the retention data, six quadratic models were obtained and their adequacy was confirmed using ANOVA test. The obtained coefficients of quadratic models enabled the elucidation of both single factor and factor interactions influence. This was also graphically presented in 3D response surface plots. [...]