Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results
2024 | 89 | 3 | 91-98

Article title

Clinical and radiological outcome of proximal third tibia fractures treated with intramedullary nailing

Content

Title variants

Languages of publication

Abstracts

EN
Introduction. Extra articular proximal tibia fractures represent about 5-11% of all tibia fractures, and usually exhibit complex fracture patterns with moderate to severe soft tissue damage and deforming forces.
No fracture arose more controversy regarding the best method of treatment, common methods of fixation of proximal tibia fractures with intramedullary nailing and minimally invasive plating widely in these fractures. The open reduction or minimally invasive plating of these fractures is widely used plates do not provide axial and varus stability and nail being load sharing device can provide both axial and varus stability, while the nail being a load sharing device can provide both axial and varus stability with minimal soft tissue handling. However, the nailing of extraarticular proximal tibia fractures is associated with malunion.
This current study aims to analyse the outcome of proximal third fractures treated with nailing.
Material and methods. Thirty consecutive patients with fracture of the proximal third of the tibia shaft underwent nailing and were followed for up to 2 years. The clinical and radiological outcome of these cases and the complications encountered were analysed according to modified Klemm and Borner scoring system.
Results. Our study comprised of patients in the age group 19-80 years, average being 40.5 years. Average time of partial weight bearing in the present study was 7.9 weeks (range 6-18 weeks). The average time for full weight bearing was 13 weeks (range 10-24 weeks). The mean time for radiological union was 24.6 weeks (range 20-32 weeks). Fourteen had excellent result, 10 patients had good, 4 patients had fair results
and 2 patients had poor results according to Klemm and Borner functional criteria.
Conclusions. Intramedullary nailing of proximal third tibia fractures when used with proper reduction technique using reduction clamps, k-wires, poller screws or unicortical plating in semi extended position for nailing is an effective, stable and successful method of treatment for proximal third fractures of tibia.

Year

Volume

89

Issue

3

Pages

91-98

Physical description

Dates

published
2024

Contributors

  • Konaseema Institute of Medical Sciences (KIMS), Amalapuram, Andhra Pradesh, India
  • Konaseema Institute of Medical Sciences (KIMS), Amalapuram, Andhra Pradesh, India
  • Konaseema Institute of Medical Sciences (KIMS), Amalapuram, Andhra Pradesh, India
author
  • Konaseema Institute of Medical Sciences (KIMS), Amalapuram, Andhra Pradesh, India

References

  • Court-Brown CM, McBirnie J. The epidemiology of tibial fractures. J Bone Joint Surg Br. 1995 May;77(3):417-21. PMID: 7744927.
  • Pape HC, Rommens PM. Proximal tibia, Chapter 6.8.1. AO Principles of fracture management, 2nd edition, New York: Thieme 2007; 828.
  • Whittle AP. Fractures of lower extremity, chapter 51. Campbell’s operative orthopedics, 11th edition, Philadelphia: Mosby Elsevier 2008; 3118.
  • Bhandari M, Audige L, Ellis T, Hanson B; Evidence-Based Orthopaedic Trauma Working Group. Operative treatment of extra-articular proximal tibial fractures. J Orthop Trauma. 2003 Sep;17(8):591-5. doi: 10.1097/00005131-200309000-00013. PMID: 14504586.
  • Martinez A, Sarmiento A, Latta LL. Closed fractures of the proximal tibia treated with a functional brace. Clin OrthopRelat Res. 2003 Dec;(417):293-302. doi: 10.1097/01.blo.0000093012.90435.e3. PMID: 14646729.
  • Sarmiento A, Latta LL. Functional treatment of closed segmental fractures of the tibia. Acta ChirOrthopTraumatol Cech. 2008 Oct;75(5):325-31. PMID: 19026185.
  • Schütz M, Kääb MJ, Haas N. Stabilization of proximal tibial fractures with the LIS-System: early clinical experience in Berlin. Injury. 2003 Aug; 34 Suppl 1:A30-5. doi: 10.1016/s0020-1383(03)00255-9. PMID: 14563008.
  • Wagner M. General principles for the clinical use of the LCP. Injury. 2003 Nov;34 Suppl 2:B31-42. doi: 10.1016/j.injury.2003.09.023. PMID: 14580984.
  • Lang GJ, Cohen BE, Bosse MJ, Kellam JF. Proximal third tibial shaft fractures. Should they be nailed? Clin OrthopRelat Res. 1995 Jun ;( 315):64-74. PMID: 7634688.
  • Singh VK, Singh Y, Singh PK, Goyal RK, Chandra H. Unreamed intramedullary nailing with oblique proximal and biplanar distal interlocking screws for proximal third tibial fractures. J OrthopSurg (Hong Kong). 2009 Apr;17(1):23-7. doi: 10.1177/230949900901700106. PMID: 19398788.
  • Freedman EL, Johnson EE. Radiographic analysis of tibial fracture malalignment following intramedullary nailing. Clin OrthopRelat Res. 1995 Jun;(315):25-33. PMID: 7634677.
  • Hiesterman TG, Shafiq BX, Cole PA. Intramedullary nailing of extra-articular proximal tibia fractures. J Am AcadOrthop Surg. 2011 Nov;19(11):690-700. doi: 10.5435/00124635-201111000-00005. PMID: 22052645.
  • Dunbar RP, Nork SE, Barei DP, Mills WJ. Provisional plating of Type III open tibia fractures prior to intramedullary nailing. J Orthop Trauma. 2005 Jul;19(6):412-4. doi: 10.1097/01.bot.0000153446.34484.70. PMID: 16003202.
  • Benirschke SK, Henley MB, Ott JW: Proximal one-third tibial fracture solutions. Orthopaedic Transactions 1995; 18:1055-1056.
  • Nork SE, Barei DP, Schildhauer TA, Agel J, Holt SK, Schrick JL, Sangeorzan BJ. Intramedullary nailing of proximal quarter tibial fractures. J Orthop Trauma. 2006 Sep;20(8):523-8. doi: 10.1097/01.bot.0000244993.60374.d6. PMID: 16990722.
  • Klemm k., Borner M. Interlocking nailing of complex fracture of the femur and tibia . Clin. Orthop., 1986.212,89.
  • Lembcke O, Rüter A, Beck A. The nail-insertion point in unreamed tibial nailing and its influence on the axial malalignment in proximal tibial fractures. Arch Orthop Trauma Surg. 2001;121(4):197-200. doi: 10.1007/s004020000200. PMID: 11317679.
  • Henley MB, Meier M, Tencer AF. Influences of some design parameters on the biomechanics of the unreamed tibial intramedullary nail. J Orthop Trauma. 1993;7(4):311-9. doi: 10.1097/00005131-199308000-00003. PMID: 8377039.
  • Krettek C, Stephan C, Schandelmaier P, Richter M, Pape HC, Miclau T. The use of Poller screws as blocking screws in stabilising tibial fractures treated with small diameter intramedullary nails. J Bone Joint Surg Br. 1999 Nov;81(6):963-8. doi: 10.1302/0301-620x.81b6.10000. PMID: 10615966.
  • Krettek C, Edwards E. Avoiding deformity in proximal tibial nailing: risk factors, deformity rules, tips, and tricks. OTA Int. 2023 Jun 16;6(3 Suppl):e257. doi: 10.1097/OI9.0000000000000257. PMID: 37533440; PMCID: PMC10392440.
  • Rommens PM, El Attal R, Hansen M, Kuhn S. IntramedulläreNagelung von proximalenTibiafrakturen [Intramedullary nailing of proximal tibia fractures]. Oper OrthopTraumatol. 2011 Dec;23(5):411-22. German. doi: 10.1007/s00064-011-0127-6. PMID: 22037620.
  • Vidyadhara S, Sharath KR. Prospective study of the clinico-radiological outcome of interlocked nailing in proximal third tibial shaft fractures. Injury. 2006 Jun;37(6):536-42. doi: 10.1016/j.injury.2006.01.042. Epub 2006 Apr 24. PMID: 16631175.
  • Liporace FA, Stadler CM, Yoon RS. Problems, tricks, and pearls in intramedullary nailing of proximal third tibial fractures. J Orthop Trauma. 2013 Jan;27(1):56-62. doi: 10.1097/BOT.0b013e318250f041. PMID: 22437426.
  • Attal R, Hansen M, Kirjavainen M, Bail H, Hammer TO, Rosenberger R, Höntzsch D, Rommens PM. A multicentre case series of tibia fractures treated with the Expert Tibia Nail (ETN). Arch Orthop Trauma Surg. 2012 Jul;132(7):975-84. doi: 10.1007/s00402-012-1502-y. Epub 2012 Mar 20. PMID: 22431141.
  • Gaurav Kumar, Varun Vijay, Nitesh Rathi, M Mohan Kumar. Analysis of extra articular proximal third tibial fractures treated with interlocked intramedullary nailing. IJOS 2017;3(1):165-171.
  • Kulkarni SG, Varshneya A, Kulkarni S, Kulkarni GS, Kulkarni MG, Kulkarni VS, Kulkarni RM. Intramedullary nailing supplemented with Poller screws for proximal tibial fractures. J OrthopSurg (Hong Kong). 2012 Dec;20(3):307-11. doi: 10.1177/230949901202000308. PMID: 23255635.
  • Kumar, Avinash, Panda, Kishore, Singh, Anurag, Kumar Singh, Anand. (2020). Intramedullary Interlocked Nail with Poller Screw Guidance for management of Extra-articular Proximal Tibial Fractures: A Prospective Study. International Journal of Current Research and Review. 12. 95-99. 10.31782/IJCRR.2020.12187.
  • Khayas Omer K, Arun K and Ravikumar V , Outcome of regular nailing in fracture of proximal third tibial shaft IJOS 2016; 2(3): 142-148.
  • Franke J, Hohendorff B, Alt V, Thormann U, Schnettler R. Suprapatellar nailing of tibial fractures-Indications and technique. Injury. 2016 Feb;47(2):495-501. doi: 10.1016/j.injury.2015.10.023. Epub 2015 Oct 20. PMID: 26553427.
  • Kulkarni MS, Tummala M, Aroor MN, Vijayan S, Rao SK. Suprapatellar nailing in proximal third tibial fractures - Clinicoradiological outcome. Injury. 2020 Aug;51(8):1879-1886. doi: 10.1016/j.injury.2020.05.008. Epub 2020 May 18. PMID: 32482425.

Document Type

Publication order reference

Identifiers

Biblioteka Nauki
63162042

YADDA identifier

bwmeta1.element.ojs-doi-10_31139_chnriop_2024_89_3_1
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.