Erythrocyte destruction in laminar (Couette) flow was investigated. Critical values of the shear stress for ovine erythrocytes from two donors were determined. Large individual differences between erythrocytes from the two donors suggest that individual determination of shear stress resistance for each donor is necessary, and that the determination of shear stress resistance might be of diagnostic value.