Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results
2014 | 61 | 3 | 471-478

Article title

Electrochemical biosensors for detection of avian influenza virus - current status and future trends

Content

Title variants

Languages of publication

EN

Abstracts

EN
Electrochemical biosensors have emerged as reliable analytical devices suitable for pathogen detection. Low cost, small sample requirement and possibility of miniaturization justifies their increasing development. Thus, we report in this review on the state of the art of avian influenza virus detection with genosensors and immunosensors working by an electrochemical mode. Their working principles focusing on the physical properties of the transducer, the immobilization chemistry, as well as new trends including incorporation of nanoparticles will be presented. Then, we critically review the detection of avian influenza virus in the complex matrices that use electrochemical biosensors and compare them with traditionally applied methods such as ELISA or Western blot.

Year

Volume

61

Issue

3

Pages

471-478

Physical description

Dates

published
2014
received
2014-05-30
revised
2014-08-12
accepted
2014-08-18
(unknown)
2014-09-03

Contributors

  • Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Olsztyn, Poland
  • Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Olsztyn, Poland
  • Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Olsztyn, Poland
author
  • Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Olsztyn, Poland
author
  • Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Olsztyn, Poland

References

  • Aoki H, Kitajima A, Tao H (2010) Label-free and 'signal-on' detection using a probe DNA terminated with ferrocene and b-cyclodextrin. Supramol Chem 22: 454-459.
  • Arya SK, Kongsuphol P, Wong ChCh, Polla LJ, Park MK (2014) Label free biosensor for sensitive human influenza virus hemagglutinin specific antibody detection using coiled-coil peptide modified microelectrode array based platform. Sens Actuators, B 194: 127-133.
  • Arya SK, Pui TS, Wong CC, Kumar S, Rahman AR (2013) Effects of the electrode size and modification protocol on a label-free electrochemical biosensor. Langmuir 29: 6770-6777.
  • Bonanni A, Pividori MI, del Valle M (2007) Application of the avidin-biotin interaction to immobilize DNA in the development of electrochemical impedance genosensors. Anal Bioanal Chem 389: 851-861.
  • Bonanni A, del Valle M (2010) Use of nanomaterials for impedimetric DNA sensors, A review. Anal Chim Acta 678: 7-17.
  • Chen R, Holmes EC (2006) Avian influenza virus exhibits rapid evolutionary dynamics. Mol Biol Evol 23: 2336-2341.
  • Chen X, Jia X, Han J, Ma J, Ma Z (2013) Electrochemical immunosensor for simultaneous detection of multiplex cancer biomarkers based on graphene nanocomposites. Biosens Bioelectron 50: 356-361.
  • Chen Y, Nguyen A, Niu L, Corn RM (2009) Fabrication of DNA microarrays with poly-l-glutamic acid monolayers on gold substrates for SPR imaging measurements. Langmuir 25: 5054-5060.
  • Chung DJ, Kim KCh, Choi SH (2011) Electrochemical DNA biosensor based on avidin-biotin conjugation for influenza virus (type A) detection. Appl Surf Sci 257: 9390-9396.
  • Davis CB, Shamansky LM, Rosenwald S, Stuart JK, Kuhr WG, Brazill SA (2003) Independently-addressable micron-sized biosensor elements. Biosens Bioelectron 18: 1299-1307.
  • Drummond TG, Hill MG, Barton JK (2003) Electrochemical DNA sensor. Nat Biotechnol 21: 1192-1199.
  • Dyadyusha L, Yin H, Jaiswal S, Brown T, Baumberg JJ, Booy FB, Melvin T (2005) Quenching of CdSe quantum dot emission, a new approach for biosensing. Chem Commun 25: 3201-3203.
  • Fan Ch, Plaxco KW, Heeger AJ (2003) Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA. Proc Natl Acad Sci 100: 9134-9137.
  • Fan H, Ju P, Ai S (2010) Controllable synthesis of CdSe nanostructures with tunable morphology and their application in DNA biosensor of Avian Influenza Virus. Sens Actuators, B 149: 98-104.
  • Farjami E, Clima L, Gothelf K, Ferapontova EE (2011) Off-on electrochemical hairpin-DNA-based genosensor for cancer diagnostics. Anal Chem 83: 1594-1602.
  • Fialova D, Krejcova L, Janu L, Blazkova I, Krystofova O, Hynek D, Kopel P, Drbohlavova J, Konecna M, Vaculovicova M, Kynicky J, Hubalek J, Babula P, Kizek R, Adam V (2013) Flow injection electrochemical analysis of complexes of influenza proteins with CdS, PbS and CuS quantum dots. Int J Electrochem Sci 8: 10805-10817.
  • Finklea HO (1996) In Electroanalytical Chemistry; Bard AJ, Rubinstein I Eds., Marcel Dekker Inc.: New York, 19: 109-112.
  • Grabowska I, Malecka K, Stachyra A, Góra-Sochacka A, Sirko A, Zagórski-Ostoja W, Radecka H, Radecki J (2013) Single electrode genosensor for simultaneous determination of sequences encoding Hemagglutinin and Neuraminidase of Avian Influenza Virus type H5N1. Anal Chem 85: 10167-10173.
  • Grabowska I, Singleton DG, Stachyra A, Góra-Sochacka A, Sirko A, Zagórski-Ostoja W, Radecka H, Stulz E, Radecki J (2014a) A highly sensitive electrochemical genosensor based on Co-porphyrin-labelled DNA. Chem Commun 50: 4196-4199.
  • Grabowska I, Stachyra A, Góra-Sochacka A, Sirko A, Olejniczak AB, Leśnikowski ZJ, Radecki J, Radecka H (2014b) DNA probe modified with 3-iron bis(dicarbollide) for electrochemical determination of DNA sequence of Avian Influenza Virus H5N1. Biosens Bioelectron 51: 170-176.
  • Hepel M, Zhong ChJ (2012) Functional nanoparticles for bioanalysis, nanomedicine, and bioelectronic devices, Volume 1. American Chemical Society, Washington, DC.
  • Hernandez FJ, Ozalp VC (2012) Graphene and other nanomaterial-based electrochemical aptasensors. Biosensors 2: 1-14.
  • Ho HT, Qian HL, He F, Meng T, Szyporta M, Prabhu N, Prabakaran M, Chan KP, Kwang J (2009) Rapid detection of H5N1 subtype influenza viruses by antigen capture enzyme-linked immunosorbent assay using H5- and N1- specific monoclonal antibodies. Clin Vaccine Immunol 16: 726-732.
  • Immoos CE, Lee SJ, Grinstaff MW (2004) DNA-PEG-DNA triblock macromolecules for reagentless DNA detection. J Am Chem Soc 126: 10814-10821.
  • Jargiło A, Grabowska I, Radecka H, Sulima M, Marszałek I, Wysłouch-Cieszyńska A, Dehaen W, Radecki J (2013) Redox active dipyrromethene-Cu(II) monolayer for oriented immobilization of His-Tagged RAGE domains - the base of electrochemical biosensor for determination of Aβ16-23'. Electroanalysis 25: 1185-1193.
  • Jarocka U, Radecka H, Malinowski T, Michalczuk L, Radecki J (2013) Detection of Prunus Necrotic Ringspot Virus in plant extracts with impedimetric immunosensor based on glassy carbon electrode. Electroanalysis 25: 433-438.
  • Jarocka U, Sawicka R, Góra-Sochacka A, Sirko A, Zagórski-Ostoja W, Radecki J, Radecka H (2014) Electrochemical immunosensor for detection of antibodies against influenza A virus H5N1 in hen serum. Biosens Bioelectron 55: 301-306.
  • Jarocka U, Wąsowicz M, Radecka H, Malinowski T, Michalczuk L, Radecki J (2011) Impedimetric immunosensor for detection of Plum Pox Virus in plant extract. Electroanalysis 23: 2197-2204.
  • Kang D, White RJ, Xia F, Zuo X, Valle-Belisle A, Plaxco KW (2012) DNA bimolecular-electronic encoder and decoder devices constructed by multiplex biosensors. NPG Asia Mat 4: 1-6.
  • Khor SM, Liu G, Fairman C, Iyengar SG, Gooding JJ (2011) The importance of interfacial design for the sensitivity of a label-free electrochemical immuno-biosensor for small organic molecules. Biosens Bioelectron 26: 2038-2044.
  • Krejcova L, Hynek D, Adam V, Hubalek J, Kizek R (2012) Electrochemical sensors and biosensors for influenza detection. Int J Electrochem Sci 7: 10779-10801.
  • Krejcova L, Hynek D, Kopel P, Adam V, Hubalek J, Trnkova L, Kizek R (2013) Paramagnetic particles isolation of influenza oligonucleotide labelled with CdS QDs. Chromatographia 76: 355-362.
  • Krejcova L, Hynek D, Michalek P, Milosavljevic V, Kopel P, Zitka O, Konecna M, Kynicki J, Adam V, Hubalek J, Kizek R (2014) Electrochemical sensors and biosensors for influenza detection - Literature Survey 2012-2013. Int J Electrochem Sci 9: 3440-3448.
  • Kukol A, Li P, Estrela P, Ko-Ferrigno P, Migliorato P (2008) Label-free electrical detection of DNA hybridization for the example of influenza virus gene sequences. Anal Biochem 374: 143-153.
  • Liu G, Iyenger SG, Gooding JJ (2013) An amperometric immunosensor based on gold nanoparticle-diazonium salt modified sensing interface for the detection of HbA1c in human blood. Electroanalysis 25: 881-887.
  • Liu G, Paddon-Row MN, Gooding JJ (2008) Protein modulation of electrochemical signals: application to immunobiosensing. Chem Commun 33: 3870-3872.
  • Liu JH, Liu JY, Yang LB, Chen X, Zhang MY, Meng FL, Luo T, Li MQ (2009) Nanomaterial-assisted signal enhancement of hybridization for DNA biosensors: a review. Sensors 9: 7343-7346.
  • Liu SF, Li YF, Li JR, Jiang L (2005) Enhancement of DNA immobilization and hybrydyzation on gold electrode modified by nanogold aggregates. Biosens Bioelectron 21: 789-795.
  • Liu X, Cheng Z, Fan H, Ai S, Han R (2011) Electrochemical detection of avian influenza virus H5N1 gene sequence using a DNA aptamer immobilized onto a hybrid nanomaterial-modified electrode. Electrochim Acta 56: 6266-6270.
  • Liu Y, Tuleouva N, Ramanculov E, Revzin A (2010) Aptamer-based electrochemical biosensor for interferon gamma detection. Anal Chem 82: 8131-8136.
  • Loget G, Wood JB, Halpern AR, Corn RM (2013) Electrodeposition of polydopamine thin films for DNA patterning and microarrays. Anal Chem 85: 9991-9995.
  • Luppa PB, Sokoll LJ, Chan DW (2001) Immunosensors-principles and applications to clinical chemistry. Clin Chim Acta 314: 1-26.
  • Luz RAS, Iost RM, Crespilho FN (2013) Nanomaterials for biosensors and implantable biodevices. In Nanobioelectrochemistry 27-48. Springer-Verlag Berlin Heidelberg 2013.
  • Malecka K, Grabowska I, Radecki J, Stachyra A, Góra-Sochacka A, Sirko A, Radecka H (2012) Voltammetric detection of a specific DNA sequence of Avian Influenza Virus H5N1 using HS-ssDNA probe deposited onto gold electrode. Electroanalysis 24: 439-446.
  • Malecka K, Grabowska I, Radecki J, Stachyra A, Góra-Sochacka A, Sirko A, Radecka H (2013) Electrochemical detection of Avian Influenza Virus genotype using amino-ssDNA probe modified gold electrodes. Electroanalysis 25: 1871-1878.
  • Mannelli M, Marco MP (2010) Recent advances in analytical and bioanalysis applications of noble metal nanorods. Anal Bioanal Chem 398: 2451-2469.
  • Mikuła E, Sulima M, Marszałek I, Wysłouch-Cieszyńska A, Verwilst P, Dehaen W, Radecki J, Radecka H (2013) Oriented immobilization of His-Tagged protein on a redox active thiol derivative of DPTA-Cu(II) layer deposited on a gold electrode-the base of electrochemical biosensors. Sensors 13: 11586-11602.
  • Ng EK, Cheng PK, Ng AY, Hoang TL, Lim WW (2005) Influenza A H5N1 detection. Emerg Infect Dis 11: 1303-1305.
  • Palecek E, Bartosik M (2012) Electrochemistry of nucleic acid. Chem Rev 112: 3427-3481.
  • Park JY, Park SM (2009) DNA hybridization sensors based on electrochemical impedance spectroscopy as a detection tool. Sensors 9: 9513-9532.
  • Patent (Polish) No: P.408351 'The way of fabrication of electroactive monolayer on the surface of gold electrode, biosensor contained electrode and its application'.
  • Peng H, Soeller Ch, Cannell MB, Bowmaker GA, Cooney RP, Travas-Sejdic J (2006) Electrochemical detection of DNA hybridization amplified by nanoparticles. Biosens Bioelectron 21: 1727-1736.
  • Prasad S (2014) Nanobiosensors: the future for diagnosis of disease? Nanobiosensors in Disease Diagnosis 3: 1-10.
  • Reddy V, Ramulu TS, Sinha B, Lim J, Hoque MR, Lee JH, Kim Ch (2012) Electrochemical detection of single nucleotide polymorphism in short DNA sequences related to cattle Fatty Acid Binding Protein 4 gene. Int J Electrochem Sci 7: 11058-11067.
  • Reyes De Courcera JI, Cavalieri RP (2003) Biosensors in encyclopedia of agricultural, food, and biological engineering, Marcel Dekker, Inc. 119-123.
  • Spichiger-Keller UE (1998) Chemical sensors and biosensors for medical and biological application. WILEY-VCH Verlag GmbH.
  • Stobiecka M, Cieśla JM, Janowska B, Tudek B, Radecka H (2007) Piezoelectric sensor for determination of genetically modified soybean Roundup Ready in samples not amplified by PCR. Sensors 7: 1462-1479.
  • Tam PD, Hieu NV, Chien ND, Le AT, Tuan MA (2009) DNA sensor based on multi-wall carbon nanotubes for label-free influenza virus (type A) detection. J Immunol Methods 350: 118-124.
  • Ting BP, Zhang J, Gao Z, Ying JY (2009) A DNA biosensors based on the detection of doxorubicin-conjugated Ag nanoparticle labels using solid-state voltammetry. Biosens Bioelectron 25: 282-287.
  • Turner AP (2013) Biosensors: sense and sensibility. Chem Soc Rev 42: 3184-3196.
  • Umezawa Y, Aoki H (2004) Ion channel based on artificial receptors. Anal Chem 76: 321A-326A.
  • Viswanathan S, Radecka H, Radecki J (2009) Electrochemical biosensor for pesticides based on acetylcholinesterase immobilized on polyaniline deposited on vertically assembled carbon nanotubes wrapped with ssDNA. Biosens Bioelectron 24: 2772-2777.
  • Wang R, Zhao J, Jiang T, Kwon YM, Lu H, Jiao P, Liao M, Li Y (2013) Selection and characterization of DNA aptamers for use in detection of avian influenza virus H5N1. J Virol Methods 189: 362-369.
  • Wąsowicz M, Milner M, Radecka D, Grzelak K, Radecka H (2010) Immunosensors incorporating anti-His (C-term) IgG F(ab') fragments attached to gold nanorods for detection of His-Tagged proteins in culture medium. Sensors 10: 5409-5424.
  • WHO (2222) report:
  • Wicklein B, del Burgo MAM, Yuste M, Carregal-Romero E, Llobera A, Darder M, Aranda P, Ortin J, del Real G, Fernandez-Sanchez C, Ruiz-Hitzky E (2013) Biomimetic architectures for the impedimetric discrimination of influenza virus phenotypes. Adv Funct Mater 23: 254-262.
  • Xie Z, Huang J, Luo S, Xie Z, Xie L, Liu J, Pang Y, Deng X, Fan Q (2014) Ultrasensitive electrochemical immunoassay for Avian Influenza subtype H5 using nanocomposite. PLoS ONE 9: e94685.
  • Zhang J, Lao R, Song S, Yan Z, Fan Ch (2008) Design of an oligonucleotide-incorporated nonfouling surface and its application in electrochemical DNA sensors for highly sensitive and sequence-specific detection of target DNA. Anal Chem 80: 9029-9033.
  • Zhu X, Ai S, Chen Q, Yin H, Xu J (2009) Label-free electrochemical detection of Avian Influenza Virus genotype utilizing multi-walled carbon nanotubes-cobalt phthalocyanine-PAMAM nanocomposite modified glassy carbon electrode. Electrochem Commun 11: 1543-1546.

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.bwnjournal-article-abpv61p471kz
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.