The Procedure for SPECT and BEAM Images Adjustment Visualisation of EEG Electrodes in SPECT Images

Content

Title variants

Languages of publication

EN

Abstracts

EN
Preliminary results of research to devise a method allowing spatial alignment of BEAM maps obtained from EEG examinations with SPECT data are presented. The main concept of the method presented lies in simultaneous recording of multi-channel EEGs during SPECT examination, and also in visualizing location of EEG electrodes on SPECT images that provide spatial three dimensional coordinates assignment. The proposed methodology of simultaneous SPECT and EEG examinations could be a significant complement to results of epileptic focus localisation obtained with the ISAS method used for the last few years. The ISAS method allows localisation of focuses with 80% confidence, but it requires carrying out MRI examinations for alignment of compared anatomical structures on two SPECT images. Complementing these results with a BEAM map analysis would improve significantly the effectiveness of the examinations. This work presents results of experiments carried out on the Jaszczak phantom.

Publisher

Year

Volume

13

Issue

3

Pages

115-125

Physical description

Dates

published
1 - 1 - 2007
online
30 - 12 - 2008

Contributors

  • Institute of Biocybernetics and Biomedical Engineering PAS, 02-109 Warsaw, 4 Ks. Trojdena str., Poland
  • Medical University Department of Nuclear Medicine, 02-097 Warsaw, 1 Banacha str., Poland
author
  • Medical University Department of Nuclear Medicine, 02-097 Warsaw, 1 Banacha str., Poland
author
  • Institute of Biocybernetics and Biomedical Engineering PAS, 02-109 Warsaw, 4 Ks. Trojdena str., Poland
  • Institute of Biocybernetics and Biomedical Engineering PAS, 02-109 Warsaw, 4 Ks. Trojdena str., Poland
  • MEDISOFT, 02-732 Warsaw, 27/32 Podbipięty str., Poland
author
  • Medical University Department of Neurosurgery, 02-097 Warsaw, 1a Banacha str., Poland
  • Institute of Biocybernetics and Biomedical Engineering PAS, 02-109 Warsaw, 4 Ks. Trojdena str., Poland

References

  • Chang DJ, Zubal G, Gottschalk C, Necochea A, Stokking R, Studholme C, Corsi M, Slavski J, Spencer SS, Blumenfeld H. Comparison of Statistical Parametric Mapping and SPECT difference imaging in patient with temporal lobe epilepsy, Epilepsia 2002; 43(1): 68-74.[PubMed][Crossref]
  • Goszczyńska H, Kowalczyk L, Świderski B, Kolebska K, Dec S, Zalewska E, Miszczak J. Ocena ilościowo-porównawcza sekwencji czasowych map EEG w celu ustalenia kierunków propagacji pobudzenia. XV Krajowa Konferencja Biocybernetyki i Inżynierii Biomedycznej, Wrocław, wrzesińn 2007, 87.
  • Goszczyńska H, Królicki L, Bajera A, Zalewska E, Kowalczyk L, Walerjan P, Rysz A, Kolebska K. Simultaneous SPECT and EEG studies - the procedure for SPECT and BEAM images adjustment - preliminary study, IIIrdSymposium: "Nuclear Magnetic Resonance in Chemistry, Biology and Medicine". IChO PAN, Warsaw 2007, September 22-25, 2007, 15.
  • Goszczyńska H, Królicki L, Bajera A, Zalewska E, Kowalczyk L, Walerjan P, Rysz A, Kolebska K. The procedure for SPECT and BEAM images adjustment during simultaneous SPECT and EEG examinations - preliminary study, COST Action NEUROMATH - Workshop, Rome, December 2-3, 2007, 67.
  • Goszczyńska H, Królicki L, Bajera A, Zalewska E, Walerjan P, Rysz A, Kolebska K, Kowalczyk L. Metodyka równoczesnego wykonywania badań SPECT i EEG umożliwiająca przestrzenne dopasowanie map BEAM do struktur widocznych w badaniu SPECT- raport z badań wstępnych. XV Krajowa Konferencja Biocybenetyki i Inżynierii Biomedycznej, Wrocław, wrzesień 2007, 88.
  • ---
  • Koessler L, Maillard L, Benhadid A, Vignal JP, Braun M, Vespignani H. Spatial localisation of EEG electrodes, Neurophysiol Clin 2007; 37 (2): 97-102.[Crossref]
  • Kozińska D, Chmielewski L. Nakładanie obrazów i integracja danych multimodalnych. Monografia Biocybernetyka i Inżynieria Biomedyczna 2000, pod red. M. Nałęcza, tom 8: Obrazowanie Biomedyczne, Akademicka Oficyna Wyd. Exit, Warszawa 2003, 127-164.
  • McNelly KA, LeBron Paige A, Varghese G, Zhang H, Novotny EJ, Spencer SS, Zubal G, Blumenfeld H. Localizing Value of Ictal-Interictal SPECT Analyzed by SPM (ISAS). Epilepsia 2005; 46(9).[Crossref]

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.-psjd-doi-10_2478_v10013-007-0010-9
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.