Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results

Journal

2008 | 3 | 4 | 438-445

Article title

Optimizing the degree of distension and reducing discomfort in CT colonography by means of a microprocessor interface system for air insufflation

Content

Title variants

Languages of publication

EN

Abstracts

EN
The patients’ discomfort during CT colonography determines which method is used and its frequency of use. The discomfort is largely associated with the colon’s insufflation with gas. A system for an automatic room-air insufflation has been developed that ensures a continuous and steady air insufflation and an increase in colonic pressure and enables a relatively fast decompression. This system provides constant pressure monitoring and can alert the operator, if necessary. The degree of discomfort was evaluated for 36 patients, who were subjected to manual and automated air insufflation. The degree of the colonic distension achieved by the two methods was compared. The data analysis showed a significantly lower level of discomfort in patients with automated air insufflation. The degree of colonic distension was evaluated by comparing the diameters of similar segments of the colon, as well as by the subjective opinion of the operator. The distension with automated air insufflation was higher than that with manual air insufflation. In some cases there was a significant difference (P<0,05). In conclusion, the results show that the automatic insufflation of air at room temperature can be used to optimize CT colonography.

Publisher

Journal

Year

Volume

3

Issue

4

Pages

438-445

Physical description

Dates

published
1 - 12 - 2008
online
22 - 10 - 2008

Contributors

  • Department of Image Diagnostics, Radiology and Nuclear Medicine, Medical University, 4002, Plovdiv, Bulgaria
  • Department of Biophysics, Medical University, 4002, Plovdiv, Bulgaria
  • Department of Biophysics, Medical University, 4002, Plovdiv, Bulgaria
  • Department of Biophysics, Medical University, 4002, Plovdiv, Bulgaria
  • Department of Image Diagnostics, Radiology and Nuclear Medicine, Medical University, 4002, Plovdiv, Bulgaria
  • Department of Image Diagnostics, Radiology and Nuclear Medicine, Medical University, 4002, Plovdiv, Bulgaria

References

  • [1] Bruzzi J.F., Moss A.C., Brennan D.D., MacMathuna P., Fenlon HM., Efficacy of IV Buscopan as a muscle relaxant in CT colonography, Eur. Radiol. 2003, 13, 2264–2270 http://dx.doi.org/10.1007/s00330-003-2012-7[Crossref]
  • [2] Laghi A., Virtual colonoscopy: clinical application, Eur. Radiol., 2005, 15, D138–141 http://dx.doi.org/10.1007/s10406-005-0125-6[Crossref]
  • [3] Bretthauer M., Hoff G., Thiis-Evensen E., Grotmol T., Holmsen S.T., Moritz V., et al., Carbon dioxide insufflation reduces discomfort due to flexible sigmoidoscopy in colorectal cancer screening. Scand. J. Gastroenterol., 2002, 37, 1103–1107 http://dx.doi.org/10.1080/003655202320378329[Crossref]
  • [4] Burling D., Taylor S.A., Halligan S., Gartner L., Paliwalla M., Peiris C., et al., Automated insufflation of carbon dioxide for MDCT colonography: distension and patient experience compared with manual insufflation. AJR, 2006, 186, 96–103 http://dx.doi.org/10.2214/AJR.04.1506[Crossref]
  • [5] Taylor S.A., Halligan S., Goh V., Morley S., Bassett P., Atkin W., et al., Optimizing colonic distension for multi-detector row CT colonography: effect of hyoscine butylbromide and rectal balloon catheter, Radiology, 2003, 229, 99–108 http://dx.doi.org/10.1148/radiol.2291021151[Crossref]
  • [6] Shinners T.J., Pickhardt P.J., Taylor A.J., Jones D.A., Olsen C.H., Patient-controlled room air insufflation versus automated carbon dioxide delivery for CT colonography, AJR, 2006, 186, 1491–1496 http://dx.doi.org/10.2214/AJR.05.0416[Crossref]
  • [7] Bretthauer M., Hoff G.S., Thiis-Evensen E., Huppertz-Hauss G., Skovlund E., Air and carbon dioxide volumes insufflated during colonoscopy. Gastrointest. Endosc. 2003, 58, 203–206 http://dx.doi.org/10.1067/mge.2003.340[Crossref]
  • [8] Church J., Delaney C., Randomized controlled trial of carbon dioxide insufflation during colonoscopy. Dis. Colon. Rectum., 2003, 46, 322–326 http://dx.doi.org/10.1007/s10350-004-6549-6[Crossref]
  • [9] Park S.H., Yee J., Kim S.H., Kim Y.H., Fundamental elements for successful performance of CT colonography (virtual colonoscopy), Korean J. Radiol., 2007, 8, 264–275 http://dx.doi.org/10.3348/kjr.2007.8.4.264[WoS][Crossref]
  • [10] Svensson M.H., Svensson E., Hellstrom M., Bowel wall visualisation at CT colonography, Acta Radiol., 2002, 43, 87–95 http://dx.doi.org/10.1080/028418502127347501[Crossref]
  • [11] Goei R., Nix M., Kessels A.H., Ten Tusscher M.P., Use of antispasmodic drugs in double contrast barium enema examination: glucagon or buscopan?, Clin. Radiol., 1995, 50, 553–557 http://dx.doi.org/10.1016/S0009-9260(05)83191-5[Crossref]
  • [12] Morrin M.M., Farrell R.J., Keogan M.T., Kruskal J.B., Yam C.S., Raptopoulos V. CT colonography: colonic distension improved by dual positioning but not intravenous glucagon. Eur. Radiol. 2002, 12, 525–530 [Crossref]
  • [13] Yee J., CT colonography: examination prerequisites, Abdom. Imaging 2002, 27, 244–252 [Crossref]
  • [14] Albinsson S, Nordström I, Hellstrand P., Stretch of the vascular wall induces smooth muscle differentiation by promoting actin polymerization, J Biol. Chem., 2004, 13, 279, 34849–34855
  • [15] Hamill O.P., Twenty odd years of stretch-sensitive channels. Pflugers. Arch. 2006, 453, 333–351 http://dx.doi.org/10.1007/s00424-006-0131-0[Crossref]
  • [16] Taylor S.A., Halligan S., Bartram C., CT colonography: methods, pathology and pitfalls, Clin. Radiol., 2003, 58, 179–190 http://dx.doi.org/10.1016/S0009-9260(02)00508-1[Crossref]
  • [17] Rogalla P., Schmidt E., Korves M., Hamm BD,. Optimal colon distension for virtual colonoscopy: room air versus CO2 insufflation, Radiology, 1999, (Suppl 213), 76
  • [18] Dachman AH. Advice for optimizing colonic distension and minimizing risk of perforation during CT colonography, Radiology. 2006, 239, 317–321 http://dx.doi.org/10.1148/radiol.2392051374[Crossref]
  • [19] Van Hee R., An abdominal challenge: the compartment syndrome, G Chir 2007, 28, 413–418

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.-psjd-doi-10_2478_s11536-008-0065-3
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.