Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results

Journal

2012 | 10 | 1 | 157-164

Article title

Comparison of biosensors based on gold and nanocomposite electrodes for monitoring of malic acid in wine

Content

Title variants

Languages of publication

EN

Abstracts

EN
Amperometric biosensors based on a gold planar electrode and on two types of nanocomposite electrodes consisting of multi-walled carbon nanotubes for the determination of L-malic acid designed for wine-makers were developed. The biosensors designed for wine-makers were constructed by immobilization of L-malate dehydrogenase and diaphorase within chitosan layers on the surface of the electrodes. The coenzyme NAD+ and the electrochemical mediator ferricyanide were present in the measuring solution. The current resulting from re-oxidation of produced ferrocyanide was measured at a working potential of +300 mV against an Ag/AgCl reference electrode. The biosensor based on a gold electrode showed linearity over the range 10–520 µM with a detection limit of 5.41 µM. Calibration curves for biosensors utilizing nanocomposites were obtained both with the linear range of 10 to 610 µM. The detection limits were 1.57 and 1.77 µM, respectively. The biosensors showed satisfactory operational stability (no loss of sensitivity after 30 consecutive measurements) and storage stability (90% of the initial sensitivity after one year of storage at room temperature). The results obtained from measurements of wine samples were in a good correlation with the standard HPLC method. Satisfactory biosensor sensitivity, specificity and stability allowed their successful commercialization.

Publisher

Journal

Year

Volume

10

Issue

1

Pages

157-164

Physical description

Dates

published
1 - 2 - 2012
online
24 - 11 - 2011

Contributors

  • Slovak University of Technology
  • Biorealis s.r.o.
author
  • Slovak University of Technology
  • Slovak University of Technology

References

  • [1] H.U. Bergmeyer, Methods of enzymatic analysis, metabolites 2: Tria- and dicarboxylic acids, purines, pyrimidines and derivates, coenzymes, inorganic compounds (Wiley-VCH, Weinheim, Germany, 1985)
  • [2] M. Toit, L. Engelbrecht, E. Lerm, S. Krieger-Weber, Food. Bioprocess. Technol. 1, 1 (2010)
  • [3] S. Maicas, I. Pardo, S. Ferrer, Int. J. Food Sci. Technol. 35, 75 (2000) http://dx.doi.org/10.1046/j.1365-2621.2000.00359.x[Crossref]
  • [4] J.L.F.C. Lima, T.I.M.S. Lopes, A.O.S.S. Rangel, Anal. Chim. Acta. 366, 187 (1998) http://dx.doi.org/10.1016/S0003-2670(98)00106-8[Crossref]
  • [5] I. Mato, J.F. Huidobro, M.P. Sanchez, S. Muniategui, M.A. Fernandez-Muino, M.T. Sancho, Food Chem. 62, 503 (1998) http://dx.doi.org/10.1016/S0308-8146(97)00166-0[Crossref]
  • [6] M. Palma, C.G. Barroso, Anal. Chim. Acta. 458, 119 (2002) http://dx.doi.org/10.1016/S0003-2670(01)01527-6[Crossref]
  • [7] T. Perez-Ruiz, C. Martinez-Lozano, V. Tomas, J. Martin, J. Chromatogr. A. 1026, 57 (2004) http://dx.doi.org/10.1016/j.chroma.2003.10.130[Crossref]
  • [8] J. Katrlik, A. Pizzariello, V. Mastihuba, J. Svorc, M. Stredansky, S. Miertus, Anal. Chim. Acta. 379, 193 (1999) http://dx.doi.org/10.1016/S0003-2670(98)00610-2[Crossref]
  • [9] M. Arif, S.J. Setford, K.S. Burton, I.E. Tothill, Analyst 127, 104 (2002) http://dx.doi.org/10.1039/b106400m[Crossref]
  • [10] F. Mazzei, F. Botre, G. Favero, Microchem. J. 87, 81 (2007) http://dx.doi.org/10.1016/j.microc.2007.05.009[Crossref]
  • [11] M. Esti, G. Volpe, L. Micheli, E. Delibato, D. Compagnone, D. Moscone, G. Palleschi, Anal. Chim. Acta. 513, 357 (2004) http://dx.doi.org/10.1016/j.aca.2003.12.011[Crossref]
  • [12] N. Gajovic, A. Warsinke, F.W. Scheller J. Biotechnol. 61, 129 (1998) http://dx.doi.org/10.1016/S0168-1656(98)00029-7[Crossref]
  • [13] N. Gajovic, A. Warsinke, F.W. Scheller, J. Chem. Technol. Biotechnol. 68, 31 (1999) http://dx.doi.org/10.1002/(SICI)1097-4660(199701)68:1<31::AID-JCTB599>3.0.CO;2-A[Crossref]
  • [14] S. Miertus, J. Katrlik, A. Pizzariello, M. Stredansky, J. Svitel, J. Svorc, Biosens. Bioelectron. 13, 911 (1998) http://dx.doi.org/10.1016/S0956-5663(98)00063-3[Crossref]
  • [15] B. Bucur, E. Mallat, A.-M. Gurban, Y. Gocheva, C. Velasco, J.-L. Marty, T. Noguer, Biosens. Bioelectron. 21, 2290 (2006) http://dx.doi.org/10.1016/j.bios.2005.10.022[Crossref]
  • [16] M. Gilis, M. Comtat, Sensor Actuat. B-Chem. 26–27, 417 (1995) http://dx.doi.org/10.1016/0925-4005(94)01630-Z[Crossref]
  • [17] R. Monosik, M. Stredansky, J. Tkac, E. Sturdik, Food Anal. Method. DOI: 10.1007/s12161-011-9222-4 [Crossref]
  • [18] S. Iijima, Nature 354, 56 (1991) http://dx.doi.org/10.1038/354056a0[Crossref]
  • [19] J. Wang, Electroanalysis 17, 7 (2005) http://dx.doi.org/10.1002/elan.200403113[Crossref]
  • [20] G. Li, J.M. Liao, G.Q. Hu, N.Z. Ma, P.J. Wu, Biosens. Bioelectron. 20, 2140 (2005) http://dx.doi.org/10.1016/j.bios.2004.09.005[Crossref]
  • [21] M. Musameh, J. Wang, A. Merkoci, Y. Lin, Electrochem. Commun. 4, 743 (2002) http://dx.doi.org/10.1016/S1388-2481(02)00451-4[Crossref]
  • [22] M. Gamella, S. Campuzano, F. Conzuelo, J.A. Curiel, R. Munoz, A.J. Reviejo, J. M. Pingarron, Talanta 81, 925 (2010) http://dx.doi.org/10.1016/j.talanta.2010.01.038[Crossref]
  • [23] A. Arvinte, L. Rotariu, C. Bala, A.M. Gurban, Bioelectrochemistry 76, 107 (2009) http://dx.doi.org/10.1016/j.bioelechem.2009.04.005[Crossref]
  • [24] A. Arvinte, L. Rotariu, C. Bala, Sensors 8, 1497 (2008) http://dx.doi.org/10.3390/s8031497[Crossref]
  • [25] J. Tkac, T. Ruzgas, Electrochem. Commun. 8, 899 (2006) http://dx.doi.org/10.1016/j.elecom.2006.03.028[Crossref]
  • [26] U.B. Trivedi, D. Lakshminarayana, I.L. Kothari, P.B. Patel, C.J. Panchal, Sens. Actuators, B 136, 45 (2009) http://dx.doi.org/10.1016/j.snb.2008.10.020[Crossref]
  • [27] A.M. Gurman, B. Prieto-Simon, J.L. Marty, T. Noguer, Anal. Lett. 39, 1543 (2006) http://dx.doi.org/10.1080/00032710600713214[Crossref]
  • [28] A.F. Groboillot, C.P. Champagne, G.D. Darling, D. Poncelet, R.J. Neufild, Biotechnol. Bioeng. 42, 1157 (1993) http://dx.doi.org/10.1002/bit.260421005[Crossref]
  • [29] B. Krajewska, Microb. Technol. 35, 126 (2004) http://dx.doi.org/10.1016/j.enzmictec.2003.12.013[Crossref]
  • [30] M. Nishiyama, N. Matsubara, K. Yamamoto, S. Iijima, T. Uozumi, T. Beppu, J. Biol. Chem. 261, 14178 (1986)
  • [31] H. Huang, N.F. Hu, Y.H. Zeng, G. Zhou, Anal. Biochem. 308, 141 (2002) http://dx.doi.org/10.1016/S0003-2697(02)00242-7[Crossref]
  • [32] Y. Tan, W. Deng, B. Ge, Q. Xie, J. Huang, S. Yao, Biosens. Bioelectron. 24, 2225 (2009) http://dx.doi.org/10.1016/j.bios.2008.11.026[Crossref]
  • [33] M.G. Zhang, A. Smith, W. Gorski, Anal. Chem. 76, 5045 (2004) http://dx.doi.org/10.1021/ac049519u[Crossref]
  • [34] Q. Zhou, Q. Xie, Y. Fu, Z. Su, X. Jia, S. Yao, J. Phys. Chem. B 111, 11276 (2007) http://dx.doi.org/10.1021/jp073884i[Crossref]
  • [35] Y. Liu, X.H. Qu, H.W. Guo, H.J. Chen, B.F. Liu, S.J. Dong, Biosens. Bioelectron. 21, 2195 (2006) http://dx.doi.org/10.1016/j.bios.2005.11.014[Crossref]

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.-psjd-doi-10_2478_s11532-011-0118-3
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.