Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results

Journal

2010 | 8 | 5 | 1034-1040

Article title

Screen-printed electrodes modified with HRP-zirconium alcoxide film for the development of a biosensor for acetaminophen detection

Content

Title variants

Languages of publication

EN

Abstracts

EN
The development of a biosensor based on the immobilization of horseradish peroxidase (HRP) within a zirconium alkoxide-polyetilenimine film onto screen-printed electrodes (SPE) for acetaminophen detection and acetaminophen quantification in pharmaceutical products is described. The biosensor operation mode is based on monitoring the amperometric signal produced by the electrochemical reduction of the enzymatically generated electroactive oxidized species of acetaminophen in the presence of hydrogen peroxide. The enzyme immobilization is performed by retention in a polyethylenimine-zirconium alcoxide porous gel film, a technique that offers good entrapping and a protective environment for the biocomponent due to the hydration properties of the immobilization layer. SPEs have the advantage of being easily mass-produced at low costs with superior characteristics in comparison with classical electrode materials. In this configuration, zirconium alkoxide demonstrates its electrocatalytic activity. The biosensor allows the quantification of acetaminophen with a limit of detection of 6.21×10−8 M and a linear range between 4.35×10−7 M and 4.98×10−6 M. Finally, the biosensor is applied to the quantitative analysis of acetaminophen in Perdolan® tablets. [...]

Publisher

Journal

Year

Volume

8

Issue

5

Pages

1034-1040

Physical description

Dates

published
1 - 10 - 2010
online
5 - 9 - 2010

Contributors

author
  • Analytical Chemistry Department, Faculty of Pharmacy, “IULIU HAŢIEGANU” University of Medicine and Pharmacy, Cluj-Napoca, 400349, Romania
  • Analytical Chemistry Department, Faculty of Pharmacy, “IULIU HAŢIEGANU” University of Medicine and Pharmacy, Cluj-Napoca, 400349, Romania
author
  • Analytical Chemistry Department, Faculty of Pharmacy, “IULIU HAŢIEGANU” University of Medicine and Pharmacy, Cluj-Napoca, 400349, Romania
  • Analytical Chemistry Department, Faculty of Pharmacy, “IULIU HAŢIEGANU” University of Medicine and Pharmacy, Cluj-Napoca, 400349, Romania
  • Analytical Chemistry Department, Faculty of Pharmacy, “IULIU HAŢIEGANU” University of Medicine and Pharmacy, Cluj-Napoca, 400349, Romania

References

  • [1] S.V. Dzyadevych, V.N. Arkhypova, A.P. Soldatkin, A.V. Elskaya, C. Martelet, N. Jaffrezic-Renault, ITBM-RBM 29, 171 (2008)
  • [2] D.R. Thevenot, K. Toth, R.A. Durst et al., Biosens. Bioelectron. 16, 121 (2001) http://dx.doi.org/10.1016/S0956-5663(01)00115-4[Crossref]
  • [3] J. Wang, Analyst 119, 763 (1994) http://dx.doi.org/10.1039/an9941900763[Crossref]
  • [4] X. Xu, S. Zhang, H. Chen, J. Kong, Talanta 80,1, 8 (2009) http://dx.doi.org/10.1016/j.talanta.2009.06.039[Crossref]
  • [5] I. Palchetti, M. Mascini, M. Minunni, A.R. Bilia, F.F. Vincieri, J. Pharm. Biomed. Anal. 32, 2, 251 (2003) http://dx.doi.org/10.1016/S0731-7085(03)00132-8[Crossref]
  • [6] M.L. Rodriguez-Mendez, M. Gay, C. Apetrei, J.A. De Saja, Electrochim. acta 54, 27, 7033 (2009) http://dx.doi.org/10.1016/j.electacta.2009.07.024[Crossref]
  • [7] Y. Zhang, P. He, N. Hu, Electrochem. Acta 49, 1981 (2004) http://dx.doi.org/10.1016/j.electacta.2003.12.028[Crossref]
  • [8] T.J. Castilho, M.P. Taboada Sotomayor, L.T. Kubota, J. Pharm. Biomed. Anal. 37, 785 (2005) http://dx.doi.org/10.1016/j.jpba.2004.11.043[Crossref]
  • [9] J. Wu, F. Yan, X. Zhang, Y. Yan, J. Tang, H. Ju, Clin. Chem. 54, 1481 (2008) http://dx.doi.org/10.1373/clinchem.2007.102350[Crossref]
  • [10] N.V. Panini, G.A. Messina, E. Salinas, H. Fernandez, J. Raba, Biosens. Bioelectron. 23, 1145 (2008) http://dx.doi.org/10.1016/j.bios.2007.11.003[Crossref]
  • [11] X.H. Fu, Bioprocess. Biosyst. Eng. 31, 69 (2008) http://dx.doi.org/10.1007/s00449-007-0147-7[Crossref]
  • [12] R.I. Stefan, R.G. Bokretsion, J.F. Staden, H.Y. Aboul-Enein, J. Pharm. Biomed. Anal. 33, 323 (2003) http://dx.doi.org/10.1016/S0731-7085(03)00284-X[Crossref]
  • [13] V. Hooda, A. Gahlaut, H. Kumar, C.S. Pundir, Sens. Actuators B 136, 235 (2009) http://dx.doi.org/10.1016/j.snb.2008.09.047[Crossref]
  • [14] J. Poljakova, K. Forsterova, M. Sulc, E. Frei, M. Stiborova, Biomed. Pap. Med. Fac. Univ. Palacky, Olomouc Czech Rep. 149, 449 (2005) (In Czech)
  • [15] J. Lin, C. He, Y. Zhao, S. Zhang, Sens. Actuators B 137, 768 (2009) http://dx.doi.org/10.1016/j.snb.2009.01.033[Crossref]
  • [16] F. Ghamouss, S. Ledru, N. Ruille, F. Lantier, M. Boujtita, Anal. Chim. Acta 570, 158 (2006) http://dx.doi.org/10.1016/j.aca.2006.04.022[Crossref]
  • [17] D. Yu, B. Blankert, J.M. Kauffmann, Biosens. Bioelectron. 22, 2707 (2007) http://dx.doi.org/10.1016/j.bios.2006.11.013[Crossref]
  • [18] A. Elyacoubi, S.I. Zayed, B. Blankert, J.M. Kauffmann, Electroanalysis 18, 4, 345 (2006) http://dx.doi.org/10.1002/elan.200503418[Crossref]
  • [19] Z. Tong, R. Yuan, Y. Chai, Y. Xie, S. Chen, J. Biotechnol. 128, 567 (2007) http://dx.doi.org/10.1016/j.jbiotec.2006.12.008[Crossref]
  • [20] S. Yang, Z. Chen, X. Jin, X. Lin, Electrochim. Acta 52, 200 (2006) http://dx.doi.org/10.1016/j.electacta.2006.04.059[Crossref]
  • [21] A.M. Azevedo, D.M. Prazeres, J.M. Cabral, L.P. Fonseca, Biosens. Bioelectron. 21, 235 (2005) http://dx.doi.org/10.1016/j.bios.2004.09.030[Crossref]
  • [22] S. Liu, Z. Dai, H. Chen, H. Ju, Biosens. Bioelectron. 9, 963 (2004) http://dx.doi.org/10.1016/j.bios.2003.08.025[Crossref]
  • [23] Y. Zhang, X. Chen, W. Yang, Sensors Actuators B 130, 682 (2008) http://dx.doi.org/10.1016/j.snb.2007.10.034[Crossref]
  • [24] Y. Yang, Z. Wang, M. Yang, J. Li, F. Zheng, G. Shen, R. Yu, Anal. Chim. Acta 584, 268 (2007) http://dx.doi.org/10.1016/j.aca.2006.11.055[Crossref]
  • [25] X. Yang, X. Chen, L. Yang, W. Yang, Bioelectrochemistry 74, 90 (2008) http://dx.doi.org/10.1016/j.bioelechem.2008.05.002[Crossref]
  • [26] V. Sima, C. Cristea, F. Lăpăduş, I.O. Marian, A. Marian, R. Săndulescu, J. Pharm. Biomed. Anal. 48, 1195 (2008) http://dx.doi.org/10.1016/j.jpba.2008.08.018[Crossref]
  • [27] D. Yu, O. Dominguez Renedo, B. Blankert, V. Sima, R. Săndulescu, J. Arcos, J.M. Kauffmann, Electroanalysis 18, 17, 1637 (2006) http://dx.doi.org/10.1002/elan.200603579[Crossref]
  • [28] B. Liu, Y. Cao, D. Chon, J. Kong, J. Deng, Anal. Chim. Acta 478, 59 (2003) http://dx.doi.org/10.1016/S0003-2670(02)01480-0[Crossref]
  • [29] G.A. Messina, I.E. De Vito, J. Raba, Anal. Chim. Acta 559, 152 (2006) http://dx.doi.org/10.1016/j.aca.2005.11.072[Crossref]

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.-psjd-doi-10_2478_s11532-010-0070-7
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.