Article title

Comparison of haemodynamic effects of noninvasive ventilation delivered via ResQGARD and CPAP boussignac masks

Content

Title variants

Languages of publication

EN

Abstracts

EN
Noninvasive ventilation (NIV) is a technique of mechanical ventilation which does not require invasive airway management, i.e. intubation or tracheostomy. In emergency medicine Continuous Positive Airway Pressure (CPAP) is used often. A new method of NIV is Impedance Threshold Device (ITD). Breathing through an ITD is utilized to raise blood pressure in hypotensive patients.Aim of the study was to compare haemodynamic effects of NIV ITD and NIV CPAP.Material and methods. This study involved a group of 25 healthy volunteers. NIV was performed using ResQGARD ITD and CPAP Boussignac. Ventilation time was 25 minutes for each mask in each participant. Every three minutes parameters were collected: SpO2, BP and HR. There was a one hour interval in between ventilation with each mask. CPAP pressure was set at a level of 8 cm H2O and the mean inspiratory resistance of the ITD was 7cm H2O. Collected parameters were subjected to ANOVA statistical analysis.Results. Absolute comparison of BP, HR and SpO2 values did not reveal statistically significant differences between the masks. However considering blood pressure levels at entry, ventilation through an ITD significantly raised BP. Ventilation with NIV CPAP did not change significantly BP.Conclusion. Ventilation through an ITD device significantly improve haemodynamic function, whereas CPAP ventilation had no significant effect on it.

Publisher

Year

Volume

85

Issue

3

Pages

129-132

Physical description

Dates

published
1 - 03 - 2013
online
20 - 04 - 2013

Contributors

  • Department of Hygiene and Health Promotion, Medical University in Łódź, Kierownik: prof. dr hab. F. Szatko
  • Department of Emergency Medicine and Disaster Medicine, Medical University in Łódź, Kierownik: dr hab. T. Gaszyński
  • Department of Anesthesiology and Intensive Therapy, Medical University in Łódź, Kierownik: prof. dr hab. W. Gaszyński
  • Department of Anesthesiology and Intensive Therapy, Medical University in Łódź, Kierownik: prof. dr hab. W. Gaszyński
  • Department of Emergency Medicine and Disaster Medicine, Medical University in Łódź, Kierownik: dr hab. T. Gaszyński

References

  • 1. Moritz F, Benichou J, Vanheste M et al.: Boussignac continuous positive airway pressure device in the emergency care of acute cardiogenic pulmonary oedema: a randomized pilot study. Eur J EmergMed 2003; 10(3): 204-08.
  • 2. Lindstrom DA , Parquette BA : Use of an ITD increases blood pressure in spontaneously breathing hypotensive patients. Prehosp Emerg Care 2009; 13(1): 99-100.
  • 3. Pantazopoulos, C, Karacosta E, Vallianatou L et al.: Impedance threshold device (ResQGARD) increases systolic blood pressure in hypotensive patients in the emergency department: 13AP2-3. EurJ Anaesthes 2011; 28: 191
  • 4. Smith SW , Parquette B, Lindstrom D et al.: an impedance threshold device increases blood pressure in hypotensive patients. J Emerge Med 2011; 41(5): 549-58.[Crossref]
  • 5. Convertino VA, Ryan KL , Rickards CA et al.: Inspiratory resistance maintains arterial pressure during central hypovolemia: Implications for treatment of patients with severe hemorrhage. CritCare Med 2007; 35(4): 1145-52.
  • 6. Ryan KL , Cooke WH , Rickards CA et al.: Breathing through an inspiratory threshold device improves stroke volume during central hypovolemia in humans. J Appl Physiol 2008; 104: 1402-09.[WoS][Crossref][PubMed]
  • 7. Convertino VA, Ratliff DA , Ryan KL et al.: Hemodynamics associated with breathing through an inspiratory impedance threshold device in human volunteers. Crit Care Med 2004; 32 (Suppl.): S381- S86.[Crossref]

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.-psjd-doi-10_2478_pjs-2013-0022
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.