NUMERICAL STUDIES OF FLUID FLOW IN FLAT, NARROW-GAP CHANNELS SIMULATING PLATE HEAT EXCHANGER

Content

Title variants

Languages of publication

EN

Abstracts

EN
The aim of this work was to present the numerical simulation results determining the distributions of flow velocity and pressure in the individual channels of a plate heat exchanger. The simulations have been conducted by means of the Finite Volume Method (FVM) of numerical computation using the ANSYS CFX software. The computational model constituted spaces between 10 flat, straight flow type plates of the heat exchanger. The obtained results of numerical simulations confirm the presence of inhomogeneous flow conditions in the neighbouring channels between the plates. The computations enabled to point out the regions on the plates, in which insufficient flow can result in problems with their cleaning. The results of this work constitute the first part of a research leading to an assessment of cleaning conditions in plate heat exchangers.

Keywords

Publisher

Year

Volume

34

Issue

4

Pages

507-514

Physical description

Dates

published
1 - 12 - 2013
online
22 - 01 - 2014

Contributors

  • Koszalin University of Technology Department of Mechanical Engineering, Division of Food Industry Processes and Facilities, ul. Racławicka 15-17, 75-620 Koszalin, Poland joanna.piepiorka@tu.koszalin.pl
  • Koszalin University of Technology Department of Mechanical Engineering, Division of Food Industry Processes and Facilities, ul. Racławicka 15-17, 75-620 Koszalin, Poland

References

  • Austin J.W., Bergeron G., 1995. Development of bacterial biofilms in dairy processing plants. J. Dairy Res., 62, 509-519. DOI: 10.1017/S0022029900031204.[Crossref]
  • Blel W., Benezech T., Legentilhomme P., Legrand J., Le Gentil-Lelievre C., 2007. Effect of flow arrangement on the removal of Bacillus spores from stainless steel equipment surfaces during a Cleaning In Place procedure. Chem. Eng. Sci., 62, 3798-3808. DOI: 10.1016/j.ces.2007.04.011.[Crossref][WoS]
  • Chen X. D., Li D. X.Y., Lin S. X.Q., Özkan N., 2004. On-line fouling/cleaning detection by measuring electric resistance - equipment development and application to milk fouling detection and chemical cleaning monitoring. J. Food Eng., 61, 181-189. DOI:10.1016/S0260-8774(03)00085-2. [Crossref]
  • de Bonis M.V., Ruocco G., 2009. Conjugate fluid flow and kinetics modeling for heat exchanger fouling simulation. Int. J. Therm. Sci., 48, 2006-2012. DOI: 10.1016/j.ijthermalsci.2009.03.010. [Crossref][WoS]
  • de Jong P., Bouman S., van der Linden H.J.L.J., 1992. Fouling of heat transfer equipment in relation to the denaturation of β-lactoglobulin. J. Soc. Dairy Technol., 45, 3-8. DOI: 10.1111/j.1471-0307.1992.tb01715.x.[Crossref]
  • Diakun J., 2011. Impact analysis for individual factors in the process of system and equipment washing. Agricultural Eng., 1 , 23-29 (in Polish).
  • Diakun J., 2013. Review, scheme and cleaning methods analysis. Polish J. Food Eng., 1/4 , 5-10.
  • Diakun J., Piepiórka J., Bil T., 2010. Polioptymalizations cleaning condition of cleaning pipelines. Problem Papers Progress of Agricultural Sciences, 546, 69-76.
  • Georgiadis M.C., Macchietto S., 2000. Dynamic modeling and simulation of plate heat exchangers under milk fouling. Chem. Eng. Sci., 55, 1605-1619. DOI: 10.1016/S0009-2509(99)00429-7.[Crossref]
  • Gillham C.R., Fryer P.J., Hasting A.P.M., Wilson D.I., 2000. Enhanced cleaning of whey protein soils using pulsed flows. J. Food Eng., 46, 199-209. DOI: 10.1016/S0260-8774(00)00083-2.[Crossref]
  • Grant C.S., Webb G.E., Jeon Y.W., 1996. Calcium phosphate decontamination of stainless steel surfaces. AIChE J., 42, 861-875. DOI: 10.1002/aic.690420324.[Crossref]
  • Grasshoff A., 1992. Hygienic design: The basis for computer controlled automation. Food and Bioprod. Process., Trans. IChemE, Part C, 70, 69-77.
  • Grijspeerdt K., Hazarika B., Vucinic D., 2003. Application of computational fluid dynamics to model the hydrodynamics of plate heat exchangers for milk processing. J. Food Eng., 57, 237-242. DOI: 10.1016/S0260-8774(02)00303-5.[Crossref]
  • Gryboś R., 1989. Basic mechanics of liquids. PWN, Warsaw (in Polish).
  • Jensen B.B.B., Friis A., Bénézech T., Legentilhomme P., Leličvre C., 2005. Local wall shear stress variations predicted by computational fluid dynamics for hygienic design. Food and Bioprod. Process., 83, 53-60. DOI: 10.1205/fbp.04021.[Crossref]
  • Jun S., Puri V.M., 2006. A 2D dynamic model for fouling performance of plate heat exchangers. J. Food Eng., 75, 364-374. DOI:10.1016/j.jfoodeng.2005.03.064.[Crossref]
  • Kazimierski Z., 2004. Podstawy mechaniki płynów i metod komputerowej symulacji przepływów. 1st edition. Lodz University of Technology, Lodz, 178 - 186; 197 - 207. ISBN 8372831335.
  • Lelievre C., Legentilhomme P., Gaucher C., Legrand J., Faille, C., Bénézech, T., 2002a. Cleaning in place: effect of local wall shear stress variation on bacterial removal from stainless steel equipment. Chem. Eng. Sci., 57, 1287-1297. DOI: 10.1016/S0009-2509(02)00019-2.[Crossref]
  • Lelievre, C., Antonini, G., Faille, C., Bénézech, T., 2002b. Cleaning-in-place, modelling of cleaning kinetics of pipes soiled by Bacillus spores assuming a process combining removal and deposition. Food and Bioprod. Process. 80, 305-311. DOI: 10.1205/096030802321154826.[Crossref]
  • Lelievre, C., Legentilhomme, P., Legrand, J., Faille, C., Bénézech, T., 2003. Hygienic design: Influence of the local wall shear stress variations on the cleanability of a three-way valve. Chem. Eng. Res. Des., 81, 1071-1076. DOI: 10.1205/026387603770866209.[Crossref]
  • Luan Z. J., Zhang G. M., Tian M. C., Fan M. X., 2008. Flow resistance and heat transfer characteristics of a newtype Plate Heat Exchanger. J. Hydrodynam., 20, 524-529. DOI: 10.1016/S1001-6058(08)60089-X.[Crossref]
  • Merheb B., Nassar G., Nongaillard B., Delaplace G., Leuliet J.C. 2007. Design and performance of a lowfrequency non-intrusive acoustic technique for monitoring fouling in plate heat exchangers. J. Food Eng., 82, 518-527. DOI:10.1016/j.jfoodeng.2007.03.022.[WoS][Crossref]
  • Piepiórka J., Diakun J., 2011. Uneven surface cleaning of heat exchanger plates. Chemical Engineering and Equipment, 50, 1, 33-34 (in Polish).
  • Tsai Y.C., Liu F.B., Shen P.T., 2009. Investigations of the pressure drop and flow distribution in a chevron-type plate heat exchanger. Int. Commun. Heat Mass Transf., 36, 574-578. DOI: 10.1016/j.icheatmasstransfer.2009.03.013. `[Crossref][WoS]