Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results
2013 | 34 | 2 | 283-291

Article title

Field Testing of Acoustic Cleaning System Working in 670Mwth CFB Boiler

Authors

Content

Title variants

Languages of publication

EN

Abstracts

EN
The article reports the results of measurements of the acoustic pressure of acoustic waves generated by acoustic dust cleaners mounted in the convection pass of the 670MWth Circulating Fluidised Bed boiler. Based on measurements carried out and the spectral analysis of recorded signals it was found that the level of acoustic pressure generated by acoustic cleaners for the frequency of 100 Hz was too low for the efficient cleaning of the heated surfaces of the reheater RH2 and superheater SH3.

Publisher

Year

Volume

34

Issue

2

Pages

283-291

Physical description

Dates

published
1 - 06 - 2013
online
09 - 07 - 2013

Contributors

author
  • Częstochowa University of Technology, Faculty of Environmental Engineering and Biotechnology, Institute of Advanced Energy Technologies, ul. Dąbrowskiego 69, 42-200 Częstochowa, Poland

References

  • Hare N., Rasul M., Moazzem S., 2010. A review on boiler deposition/foulage prevention and removal techniques for power plant. Recent Advances in Energy and Environment. Proceedings of the 5th IASME / WSEASInternational Conference on Energy & Enviroment (EE '10), 23-25 February, 2010, WSEAS press, UK. 217-222.
  • Pronobis M., 2002. Modernizacja kotłów energetycznych. Wydawnictwa Naukowo-Techniczne, Warszawa.
  • Zbogar A., Frandsen F., Jensen P., Glarborg P., 2009. Shedding of ash deposits. Prog. Energy Combust. Sci., 35, 31-56. DOI: 10.1016/j.pecs.2008.07.001.[WoS][Crossref]

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.-psjd-doi-10_2478_cpe-2013-0023
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.