Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results

Journal

2003 | 1 | 1 | 28-34

Article title

Toxicological evaluation of exposed SPMD membranes

Content

Title variants

Languages of publication

EN

Abstracts

EN
This article is focused on bioassay evaluation of exposed SPMDs. Toxicity testing of SPMD extract is a suitable complementary parameter to chemical analysis. Vtox as an integrative parameter describing toxic properties of extract from membrane and thus a level of contamination of assessed ambient is presented here. Two examples of practical use of Vtox is demonstrated: a course of toxicity throw wastewater treatment plant with industrial inlets and increase of toxicity in surface water body caused by leakages of POPs from industrial plant.

Keywords

Publisher

Journal

Year

Volume

1

Issue

1

Pages

28-34

Physical description

Dates

published
1 - 3 - 2003
online
1 - 3 - 2003

Contributors

  • Department of Environmental Chemistry, ICT, 166 28, Prague, Czech Republic
  • Department of Environmental Chemistry, ICT, 166 28, Prague, Czech Republic
  • Department of Environmental Chemistry, ICT, 166 28, Prague, Czech Republic

References

  • [1] J.N. Huckins, G.K. Manuweera, J.D. Petty, D. Mackay, J.A. Lebo: “Lipid-Containing Semipermeable Membrane Devices for Monitoring Organic Contaminants in Water”, Environ. Sci. Technol., Vol. 27, (1993), pp. 2489–2496. http://dx.doi.org/10.1021/es00048a028[Crossref]
  • [2] J.N. Huckins, J.D. Petty, C.E. Orazio, J.A. Lebo, R.C. Clark, V.L. Gibson, W.R. Gala, K.R. Echols: “Determination of Uptake Kinetics (Sampling Rates) by Lipid-Containing Semipermeable Membrane Devices (SPMDs) for Polycyclic Aromatic Hydrocarbons (PAHs) in Water”, Environ. Sci. Technol., Vol. 33, (1999), pp. 3918–3923. http://dx.doi.org/10.1021/es990440u[Crossref]
  • [3] J.N. Huckins, J.D. Petty, H.F. Prest, R.C. Clark, D.A. Alvarez, C.E. Orazio, J.A. Lebo, W.L. Cranor, B.T. Johnson: A guide for the use of Semipermeable membrane devices (SPMDs) as samplers of waterborne hydrophobic organic contaminants, Columbia Environmental Research Center, New Haven Road, Columbia, 2000.
  • [4] B.T. Johnson, J.N. Huckins, J.D. Petty, R.C. Clark: “Collection and detection of lipophilic chemical contaminants in water, sediment, soil, and air-SPMD-TOX”, Environmental Toxicology, Vol. 15, (2000), pp. 248–252. http://dx.doi.org/10.1002/1522-7278(2000)15:3<248::AID-TOX10>3.0.CO;2-Q[Crossref]
  • [5] V. Kočí, M. Mlejnek, T. Ocelka, L. Kochánková: “Application of algal bioassay for toxicity evaluation of SPMD”, Czech Phycology, Vol. 2, (2002), pp. 129–137.
  • [6] A. Kot, B. Zabiegala, J. Namiesenik: “Passive sampling for long-term monitoring of organic pollutants in water”, Trends in Analytical Chemistry, Vol. 19, (2000), pp. 446–459. http://dx.doi.org/10.1016/S0165-9936(99)00223-X[Crossref]
  • [7] J.D. Petty, C.E. Orazio, J.N. Huckins, R.W. Gale, J.A. Lebo, J.C. Meadows, K.R. Echos, W.L. Cranor: “Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants”, Journal of Chromatography, Vol. 879, (2000), pp. 83–95. http://dx.doi.org/10.1016/S0021-9673(00)00315-0[Crossref]
  • [8] J.D. Petty, S.B. Jones, J.N. Huckins, W.L. Cranor, J.T. Parris, T.B. McTague, T.P. Boyle: “An approach for assessment of water quality using semipermeable membrane devices (SPMDs) and bioindicator tests”, Chemosphere, Vol. 41, (2000), pp. 311–321. http://dx.doi.org/10.1016/S0045-6535(99)00499-3[Crossref]
  • [9] L. Pollumaa, A. Kahru, A. Eisentrager, R. Reiman, A. Maloveryan, A. Ratsep: “Toxicological Investigation of Soils with the Solid-phase Flash Assay: Comparison with Other Ecotoxicological Tests”, ATLA, Vol. 28, (2000), pp. 461–472.
  • [10] D. Sabaliũnas, J.R. Lazutka, I. Sabaliũniené: “Acute toxicity and genotoxicity of aquatic hydrophobic pollutants sampled with semipermeable membrane devices”, Environmental Pollution, Vol. 119, (2000), pp. 251–265. http://dx.doi.org/10.1016/S0269-7491(99)00259-6[Crossref]
  • [11] D. Sabaliũnas and A. Sodergren: “Use of semi-permeable membrane devices to monitor pollutants in water and assess their effects: A laboratory test and field verification”, Environmental Pollution, Vol. 96, (1997), pp. 195–205. http://dx.doi.org/10.1016/S0269-7491(97)00021-3[Crossref]

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.-psjd-doi-10_2478_BF02479255
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.