Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl
Preferences help
enabled [disable] Abstract
Number of results

Results found: 2

Number of results on page
first rewind previous Page / 1 next fast forward last

Search results

Search:
in the keywords:  ultrasonografia 3D
help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
|
|
vol. 13
|
issue 55
425-430
EN
Due to its noninvasiveness and high resolving power, ultrasound examination is the examination of choice for the imaging of the structures of the pediatric scrotum. It allows to reveal changes impossible to fi nd in the course of a clinical examination. Its signifi cance has increased over the past few years due to the technological developments. The introduction of transducers with frequency of 10–17 MHz has improved the resolution of pediatric testes images as well as the resolution of the inguinal canals images, which has been of particular importance for the evaluation of undescended, retractile and abdominal testes. New diagnostic tools have also been introduced, such as 3D imaging or elastography, whose application has helped provide valuable additional information for the evaluation of pediatric testes, for treatment monitoring, and for post-surgical follow-up examinations. 3D imaging facilitates a more accurate evaluation of the location of an undescended testicle, testicular volume, and vascularization. Elastography may be used for the evaluation of focal lesions, post-ischemic lesions, unclear fl uid spaces, undescended testes, and following orchiopexy.
PL
Ze względu na nieinwazyjność i dużą zdolność rozdzielczą badanie sonografi czne jest badaniem z wyboru w obrazowaniu struktur worka mosznowego u dzieci. Pozwala wykazać zmiany niemożliwe do stwierdzenia w badaniu klinicznym. Postępy technologiczne w ostatnich latach dodatkowo wzmocniły znaczenie tego badania. Wraz z wprowadzeniem głowic o częstotliwościach 10–17 MHz poprawiła się rozdzielczość obrazów jąder pediatrycznych oraz rozdzielczość kanałów pachwinowych, co ma szczególne znaczenie w ocenie jąder niezstąpionych i wędrujących, a także brzusznych. Pojawiły się także nowe narzędzia diagnostyczne, takie jak obrazowanie trójwymiarowe czy elastografi a, których zastosowanie może dostarczyć wielu dodatkowych informacji w ocenie jąder u dzieci, a także w monitorowaniu leczenia bądź kontrolach pooperacyjnych. Badanie 3D umożliwia dokładniejszą ocenę położenia jądra niezstąpionego, objętości jądra, a także ocenę waskularyzacji. Elastografi a może być stosowana w ocenie zmian ogniskowych, zmian poniedokrwiennych, niejasnych przestrzeni płynowych, jąder niezstąpionych i po orchidopeksji.
EN
Background: Three-dimensional (3D) ultrasound of the shoulder is characterized by a comparable accuracy to two-dimensional (2D) ultrasound. No studies investigating 2D versus 3D inter-rater reliability in the detection of supraspinatus tendon tears taking into account the level of experience of the raters have been carried out so far. Objectives: The aim of this study was to determine the inter-rater reliability in the analysis of 3D ultrasound image sets of the supraspinatus tendon between sonographer with different levels of experience. Patients and methods: Non-interventional, prospective, observational pilot study of 2309 images of 127 adult patients suffering from unilateral shoulder pain. 3D ultrasound image sets were scored by three raters independently. The intra-and interrater reliabilities were calculated. Results: There was an excellent intra-rater reliability of rater A in the overall classification of supraspinatus tendon tears (2D vs 3D κ = 0.892, pairwise reliability 93.81%, 3D scoring round 1 vs 3D scoring round 2 κ = 0.875, pairwise reliability 92.857%). The inter-rater reliability was only moderate compared to rater B on 3D (κ = 0.497, pairwise reliability 70.95%) and fair compared to rater C (κ = 0.238, pairwise reliability 42.38%). Conclusions: The reliability of 3D ultrasound of the supraspinatus tendon depends on the level of experience of the sonographer. Experience in 2D ultrasound does not seem to be sufficient for the analysis of 3D ultrasound imaging sets. Therefore, for a 3D ultrasound analysis new diagnostic criteria have to be established and taught even to experienced 2D sonographers to improve reproducibility.
PL
Wprowadzenie: Ultrasonografia trójwymiarowa (3D) barku jest uznawana za metodę o porównywalnej dokładności w stosunku do ultrasonografii dwuwymiarowej (2D). Jak dotąd nie przeprowadzono żadnego badania porównującego ultrasonografię 2D i 3D w diagnostyce zerwania ścięgna mięśnia nadgrzebieniowego z uwzględnieniem poziomu doświadczenia badaczy. Cele: Celem niniejszego badania było porównanie oceny patologii ścięgna nadgrzebieniowego za pomocą badania 3D pomiędzy operatorami o różnym poziomie doświadczenia. Pacjenci i metody: Pilotażowe nieinterwencyjne, prospektywne, obserwacyjne badanie 2309 obrazów uzyskanych z badań 127 dorosłych pacjentów cierpiących z powodu jednostronnego bólu barku. Zestawy obrazów 3D zostały ocenione w sposób niezależny przez trzech badaczy. Obliczono poziom zgodności pomiędzy badaczami oraz świadozgodność ocen jednego badacza. Wyniki: Badacz A wykazał się bardzo wysokim poziomem zgodności swoich ocen w ogólnej klasyfikacji zerwania ścięgna mięśnia nadgrzebieniowego (2D vs 3D κ = 0,892, porównywalność parami 93,81%, runda ocen obrazów 3D nr 1 vs runda ocen obrazów 3D nr 2 κ = 0,875, porównywalność parami 92,857%). Zgodność pomiędzy badaczami była tylko umiarkowana w porównaniu z badaczem B (obrazy 3D) (κ = 0,497, porównywalność parami 70,95%) i przeciętna w porównaniu z badaczem C (κ = 0,238, porównywalność parami 42,38%). Wnioski: Wiarygodność interpretacji obrazów 3D ścięgna mięśnia nadgrzebieniowego jest zależna od poziomu doświadczenia operatora. Doświadczenie w ultrasonografii 2D zdaje się być niewystarczające do analizy zestawów obrazów 3D. Z tego powodu należy opracować nowe kryteria diagnostyczne dla analizy obrazów 3D i wprowadzić nauczanie interpretacji badań ultrasonografii trójwymiarowej, aby w ten sposób zwiększyć poziom odtwarzalności.
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.