Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl
Preferences help
enabled [disable] Abstract
Number of results

Results found: 2

Number of results on page
first rewind previous Page / 1 next fast forward last

Search results

Search:
in the keywords:  metoda dyfrakcji laserowej
help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
EN
The paper presents a study on the possibility of using the laser diffraction method for measuring the size of the activated sludge particles. Susceptibility of the particles to mechanical disintegration, dependent on the programmed value of stirring intensity, was observed (stirring was caused by required dynamic flow of analysed suspension through the measurement unit). According to the conclusions presented in this paper, it may be assumed that the laser diffraction method can be applied for measurement of activated sludge particle diameters under the following conditions: 1) the size of activated sludge particles measured by the laser diffraction method is not a real value, but after standardisation of measurement conditions can be treated as a parameter describing the sludge; 2) the particle diameters of activated sludge should be stabilised before the measurement, eg by mixing in the measurement unit or by ultrasound waves application.
PL
Praca dotyczy oceny możliwości wykorzystania dyfrakcji laserowej do badania rozmiarów kłaczków osadu czynnego. W czasie pomiarów zaobserwowano podatność analizowanych cząstek na zniszczenie mechaniczne zależną od zaprogramowanej intensywności mieszania (mieszanie i przepompowywanie jest wymagane w celu wymuszenia przepływu analizowanych zawiesin przez układ pomiarowy). Na podstawie wniosków opracowanych na podstawie prowadzonych badań można stwierdzić, iż metoda dyfrakcji laserowej może być stosowana do pomiarów rozmiarów kłaczków osadu czynnego pod następującymi warunkami: rozmiary kłaczków oraz pozostałych elementów osadu czynnego uzyskane w czasie pomiarów nie mogą być traktowane jako wartość bezpośrednia opisująca rozmiary kłaczka, lecz po standaryzacji warunków pomiarowych może być traktowana jako ilościowy parametr opisujący właściwości osadu czynnego. Przed pomiarem metodą dyfrakcji laserowej osad czynny powinien być uprzednio stabilizowany na przykład za pomocą mieszania w układzie pomiarowym bądź też za pomocą ultradźwięków.
EN
The important factors that strongly influence the particle size distributions measured by the laser diffraction method are the optical parameters of the suspension (refractive index and absorption coefficient). Knowledge of the values of these parameters is necessary for Mie theory. Mie theory is applied for conversion of the intensity of light recorded on detectors into particle size distribution (PSD) of tested material. Both wastewater and activated sludge are mixtures of a variety of elements (mineral or organic, including living organisms). In practice, it is not possible to define clearly the values of the optical parameters, as the composition of the suspension changes over time. The aim of the study was to estimate the impact of assumed values of the optical parameters on particle size distributions obtained. The PSDs of suspensions sampled in different stages of wastewater treatment are the most reproducible when the following optical parameters are defined: absorption coefficients - 1.0 and the refractive index - 1.52.
PL
Czynnikami, które w istotny sposób wpływają na rozkłady granulometryczne wyznaczane za pomocą dyfrakcji laserowej, są parametry optyczne mierzonej zawiesiny (współczynnik załamania światła oraz współczynnik absorpcji). Znajomość wartości tych parametrów jest niezbędna przy zastosowaniu teorii Mie. Teoria Mie jest wykorzystywana do przeliczenia intensywności światła zmierzonego na detektorach na rozkład granulometryczny (PSD) badanego materiału. Zarówno ścieki, jak i osad czynny są mieszaninami bardzo różnych składników (mineralnych i organicznych, w tym żywych organizmów). W praktyce nie ma możliwości określenia rzeczywistych wartości parametrów optycznych mieszanin, tym bardziej, że ich skład zmienia się w czasie. Celem niniejszej pracy było określenie wpływu założonych wartości parametrów optycznych na uzyskiwane rozkłady granulometryczne. Rozkłady granulometryczne zawiesin pobranych na różnych etapach oczyszczania ścieków są najbardziej powtarzalne dla następujących wartości współczynników optycznych: współczynnika absorpcji - 1,0 i współczynnika załamania światła - 1,52.
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.