Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl
Preferences help
enabled [disable] Abstract
Number of results

Results found: 2

Number of results on page
first rewind previous Page / 1 next fast forward last

Search results

Search:
in the keywords:  "gronkowce"
help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
EN
Introduction. Shopping habits have changed over the past several years and consumers choose shopping centres, where they can spend time and visit restaurants. People usually wash hands before meals, but toilets in shopping centres are visited by hundreds of users every day which= makes their cleanliness questionable. Therefore, the aim of this study was to assess the sanitary condition of electrical hand dryers in toilets of the selected shopping centres in Kraków. Material and methods. Air was sampled at the outlet of electrical hand dryers and surface swabs of hand dryers were taken in toilets of five shopping centres. Air sampling was conducted using the MAS-100 impactor. The number of mesophilic bacteria, fungi, actinomycetes, staphylococci and Escherichia coli was determined. The results of air analyses were compared with the limits provided by the Polish Standards on air quality. Results. The number of microorganisms varied between the studied centres. In terms of mesophilic bacteria and fungi the air was unpolluted. The concentration of actinomycetes however significantly exceeded the limits set by the Polish Standards. Numerous Escherichia coli were found both in the air and in swabs in one of the centres. However the number of E. coli and staphylococci did not exceed the minimum infective dose. Conclusions. The studies showed high concentrations of airborne actinomycetes and staphylococci. Also the presence of E. coli in the air and swabs allows the conclusion that legal regulations for concentrations of airborne microorganisms are necessary to make people aware of this problem. However, it was found that using electrical hand dryers does not have impact on human health.
PL
Wstęp. W przeciągu ostatnich lat zwyczaje konsumentów znacznie się zmieniły i klienci coraz częściej rezygnują z osiedlowych sklepów na rzecz centrów handlowych, w których mogą spędzić czas, a także skorzystać z bogatych ofert restauracji. Wielu ludzi odruchowo myje ręce przed posiłkami, jednak toalety w centrach handlowych odwiedzane są przez setki osób dziennie, a ich czystość może być wątpliwa. Celem badań była ocena stanu sanitarno-higienicznego suszarek do rąk w toaletach wybranych centrów handlowych w Krakowie. Materiały i metody. Pobrano powietrze u wylotu suszarek elektrycznych oraz wymazy powierzchniowe wylotów powietrza w suszarkach w toaletach pięciu centrów handlowych. Próbki powietrza pobrano przy użyciu impaktora MAS-100. Oznaczono liczebność bakterii mezofilnych, grzybów, promieniowców, gronkowców i Escherichia coli. W przypadku badań powietrza wyniki porównano z zaleceniami Polskich Norm dotyczących jakości powietrza atmosferycznego. Wyniki. Liczebność drobnoustrojów w badanych centrach handlowych była zróżnicowana. Pod względem liczby bakterii mezofilnych i grzybów powietrze we wszystkich toaletach było niezanieczyszczone. Stężenie promieniowców znacznie przekraczało wartości dopuszczalne w Polskich Normach. Również liczba gronkowców była bardzo wysoka. W jednym z badanych centrów stwierdzono liczne bakterie Escherichia coli, zarówno w powietrzu, jak i w wymazach. Jednak liczebność zarówno E. coli jak i gronkowców nie przekroczyła granicy minimalnej dawki infekcyjnej. Wnioski. W badaniach stwierdzono wysokie stężenia promieniowców i gronkowców. Obecność E. coli w powietrzu i w suszarkach daje podstawę do stwierdzenia, że normy prawne regulujące stężenie mikroorganizmów w powietrzu są potrzebne, aby podkreślić znaczenie problemu. Stwierdzono jednakże, że korzystanie z elektrycznych suszarek do rąk nie zagraża zdrowiu użytkowników.
EN
Introduction. The air we breathe is the site of periodic occurrence of bacteria. One of the sources of bioaerosol is the gut microbiome. More and more frequently, microbes acquire resistance to antibiotics and can become a potential cause of infections. In recent years, this phenomenon is noticeable mainly in the health care facilities. Material and methods. Air samples were collected from five pharmacies located in Bydgoszcz. The impact method was used. The taxonomic analysis of culturable b-hemolytic bacterial strains was prepared using BIOLOG® technology. The susceptibility of identified staphylococci was assessed with the disc-diffusion method, in line with the recommendations of the EUCAST. Results. The results showed that the highest average number of b-hemolytic bacteria was identified at a sampling site located directly in the hospital. Identification of b-hemolytic bacteria showed that the examined strains mostly represented Bacillus and Staphylococcus genera. Based on the antibiogram, it was found that staphylococci strains showed the lowest sensitivity to penicillin, tetracycline, and erythromycin. Conclusions. The obtained results indicate that the air in pharmacies can be a source of potential pathogenic bacteria and antibiotic-resistant bacteria.
PL
Wprowadzenie. Powietrze atmosferyczne, którym oddychamy, jest miejscem okresowego przebywania mikroorganizmów. Jednym ze źródeł bioaerozolu są bakterie stanowiące naturalny mikrobiom człowieka. Coraz częś- ciej jednak drobnoustroje nabywają oporność na dostępne antybiotyki, stając się potencjalną przyczyną wtórnych infekcji. W ostatnich latach zjawisko to obserwuje się głównie w placówkach podstawowej opieki zdrowotnej. Materiał i metody. Próby powietrza pobrano z izb ekspedycyjnych aptek zlokalizowanych w Bydgoszczy z wykorzystaniem metody zderzeniowej. Analizę taksonomiczną bakterii b-hemolizujących przeprowadzono przy pomocy metody BIOLOG®, opartej na wykorzystaniu metabolicznych cech analizowanych szczepów. Lekowrażliwość zidentyfikowanych gronkowców oznaczono metodą dyfuzyjno-krążkową, zgodnie z rekomendacjami EUCAST. Wyniki. Największą średnią liczbę bakterii b-hemolizujących odnotowano na stanowisku zlokalizowanym bezpośrednio w budynku szpitala. Identyfikacja tych mikroorganizmów wykazała, że badane izolaty reprezentowane były głównie przez szczepy należące do rodzaju Staphylococcus oraz Bacillus. Na podstawie wykonanych antybiogramów stwierdzono, iż wyizolowane szczepy gronkowców największą oporność wykazywały wobec penicyliny, tetracykliny oraz erytromycyny. Wnioski. Uzyskane wyniki wskazują, iż powietrze w placówkach farmaceutycznych może być źródłem potencjalnie chorobotwórczych, lekoopornych bakterii, co ma duże znaczenie dla zdrowia publicznego.
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.