Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl
Preferences help
enabled [disable] Abstract
Number of results

Results found: 2

Number of results on page
first rewind previous Page / 1 next fast forward last

Search results

help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
EN
Introduction: Atherosclerosis (arteriosclerosis) is a chronic arterial disease of the arteries with chronic inflammatory. The pathology of atherosclerosis is complex, and the atherosclerotic process is multi-factorial, not fully understood. Risk factors of atherosclerotic lesions may include: lipid disorders, hypertension or diabetes. One of the diagnostic methods of discovering atherosclerosis covers the assessment of the intima–media complex thickness by Doppler ultrasonography. Aim: The aim of this report was an evaluation of the relationships between intima–media complex thickness in the right and left carotid arteries and the occurrence of atheromatous plaque in the Lublin population with respect to three possible concomitant medical conditions, mentioned above. Material and methods: A group of 121 subjects was included into the study, all of the participants being residential inhabitants of the Lublin Voivodship. All the participating patients were requested to fill in a questionnaire. After that, the patients were submitted to Doppler sonography concentrated on intima–media complex thickness evaluation. The occurrence of atheromatous plaque was also assessed in obtained sonographic images. Results: There were statistically significant differences for the intima–media complex thickness and for the atheromatous plaque according to all of the reported diseases: hypocholesterolaemia, hypertension and diabetes. Conclusions: The present study confirms that there is a relationship between the thickness of the intima–media complex in the right and left carotid arteries as well as the occurrence of the atherosclerotic plaque regarding the coexistence of specific disease entities in the subjects of the Lublin population.
PL
Wstęp: Miażdżyca (arterioskleroza) to przewlekła choroba naczyń tętniczych o podłożu zwyrodnieniowo-zapalnym. Patologia miażdżycy jest złożona, a proces miażdżycowy ma charakter wieloczynnikowy, nie do końca poznany. W inicjowaniu zmian miażdżycowych biorą udział różne czynniki ryzyka, do których zalicza się m.in. zaburzenia gospodarki lipidowej, nadciśnienie tętnicze i cukrzycę. Jedną z metod diagnozowania miażdżycy jest ocena grubości kompleksu intima–media za pomocą ultrasonografii dopplerowskiej. Cel pracy: Celem pracy było zbadanie zależności pomiędzy grubością kompleksu intima–media w prawej i lewej tętnicy szyjnej oraz obecnością blaszki miażdżycowej a występowaniem jednej z trzech wymienionych wyżej jednostek chorobowych w populacji lubelskiej. Materiał i metody: Badaniem objęto losowo 121 osób z populacji lubelskiej. Badanych poproszono o wypełnienie ankiety. W kolejnym kroku badani byli kwalifikowani do ultrasonograficznej oceny grubości kompleksu intima–media. Oceniano także występowanie blaszki miażdżycowej w obrazie ultrasonograficznym. Wyniki: Stwierdzono istotne statystycznie różnice w grubości kompleksu intima–media z uwzględnieniem występowania wskazanych jednostek chorobowych: hipercholesterolemii, nadciśnienia tętniczego i cukrzycy. Stwierdzono również istnienie zależności pomiędzy obecnością blaszki miażdżycowej a występowaniem wskazanych jednostek chorobowych u badanych. Wnioski: Przeprowadzone badania potwierdziły, że istnieją zależności pomiędzy grubością kompleksu intima–media w prawej i lewej tętnicy szyjnej oraz obecnością blaszki miażdżycowej a współwystępowaniem opisywanych jednostek chorobowych u badanych w populacji lubelskiej.
EN
Aim of the study: The aim of this study is to assess the prevalence and evolution of perirenal fluid collections in a group of 488 patients who have undergone kidney transplantation. Material and methods: Sonographic documentation of 488 deceased-donor kidney recipients was evaluated for the prevalence of perirenal fluid collections and their evolution in time, depending on selected demographic features of the patients, time of detection, initial dimensions and precise position of the collection relative to the kidney and the location of the transplanted organ in the right or left iliac fossa. The collected data were used for statistical analysis to determine the strength of the potential relationships. Results: In 146 out of 488 subjects perirenal fluid collections were found. In 1/3 of the patients more than one fluid collection was diagnosed. Over 40% of fluid collections were detected within 10 days from the date of the first scan and 24.11% were detected within 10–20 days from the date of the first scan. The majority of fluid collections were located near the lower pole of the kidney. Perihilar collections were the least common. Collections encapsulating the kidney and subcutaneous collections were the largest in size on average. A statistically significant difference between the size of collections located on the surface and the size of those located near the upper pole of the transplanted kidney was demonstrated. However, no correlation was proven to exist between the persistence of the fluid collection and its position relative to the transplanted kidney and its initial size. Conclusions: The correct evaluation of a fluid collection’s dynamics of development and nature requires periodic follow-up of the recipient, preferably in a single clinical center. Ultrasonography is an inexpensive, non-invasive and repeatable method for the determination of the presence of fluid collections. However, the decision whether treatment is necessary requires the sonographic image to be compared with the laboratory signs of inflammation and biochemical analysis of the contents of fluid collections.
PL
Cel pracy: Celem niniejszego opracowania jest ocena występowania i ewolucji okołonerkowych zbiorników płynowych w grupie 488 pacjentów poddanych operacji transplantacji nerki. Materiał i metody: Dokumentacja ultrasonograficzna 488 biorców nerek od dawców zmarłych została poddana ocenie pod kątem częstości występowania okołonerkowych zbiorników płynowych i ich ewolucji w czasie, w zależności od wybranych cech demograficznych pacjenta, czasu wykrycia, początkowych rozmiarów i dokładnej lokalizacji zbiornika względem nerki oraz umiejscowienia przeszczepionego narządu – w prawym lub lewym dole biodrowym. Zgromadzone dane wykorzystano do analizy statystycznej w celu określenia siły ewentualnych zależności. Wyniki: U 146 na 488 badanych stwierdzono obecność okołonerkowych zbiorników płynowych, przy czym u niemal 1/3 pacjentów zdiagnozowano więcej niż jeden zbiornik. Przeszło 40% zbiorników wykryto przed upływem 10 dni od daty pierwszego badania,a 24,11% –w okresie 10–20 dni od daty pierwszego badania. Najwięcej kolekcji płynowych było zlokalizowanychw okolicy bieguna dolnego nerki. Najrzadziej występowały zbiorniki okołownękowe. Największy średni rozmiar osiągały zbiorniki opłaszczające nerkęi leżące podskórnie. Wykazano istotną statystycznie różnicę pomiędzy wymiarami zbiorników zlokalizowanych powierzchniowo orazw okolicy bieguna górnego przeszczepionej nerki. Nie dowiedziono jednak istnienia korelacji pomiędzy trwałością zbiornikaa jego lokalizacją względem przeszczepionej nerki lub początkowym wymiarem. Wnioski: Prawidłowa ocena dynamiki rozwojui charakteru zbiornika płynowego wymaga okresowej kontroli biorcy,najlepiejw jednym ośrodku klinicznym. Ultrasonografia jest tanią, nieinwazyjnąi powtarzalną metodą oceny występowania kolekcji płynowych. Decyzjao potrzebie leczenia wymaga jednak odniesienia obrazu sonograficznego do parametrów zapalnych oraz wyników analiz biochemicznych zawartości zbiorników.
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.