Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl
Preferences help
enabled [disable] Abstract
Number of results

Results found: 2

Number of results on page
first rewind previous Page / 1 next fast forward last

Search results

Search:
in the keywords:  Allergy
help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
PL
Kinesiotaping jest obecnie uważany za samodzielną lub uzupełniającą metodę w rehabilitacji, ortopedii i medycynie sportowej. Historia kinesiotapingu sięga wczesnych lat 70-tych XX w. Techniki kinesiotapingu oraz plaster używany w tej metodzie zostały opracowane ponad 25 lat temu w Japonii przez chiropraktyka Kenzo Kase. Idea metody leży w oddziaływaniu specjalnego plastra zaaplikowanego zgodnie z zasadami kinesiotapingu. Plaster ten, wykonany z bawełny i akrylu, ma parametry (grubość, wagę, rozciągliwość itp.) bardzo zbliżone do ludzkiej skóry. Klej wykorzystywany w plastrach do kinesiotapingu uważany jest za hipoalergiczny. Artykuł przedstawia interesujący przypadek alergii podczas terapii metodą kinesiotapingu. Świadectwa dotyczące alergii podczas terapii metodą kinesiotapingu w praktyce klinicznej są rzadkie, brak jest publikacji w tym zakresie. Istnieje konieczność zwrócenia szczególnej uwagi na reakcję skóry na kombinację substancji używanych do produkcji kleju stosowanego w plastrach i środków używanych do przygotowania skóry do aplikacji kinesiotapingu. Niezbędne są dalsze badanie w celu określenia możliwego źródła (źródeł) alergii. Przedstawiony opis przypadku może być świadectwem, że podczas terapii metodą kinesiotapingu oprócz możliwości alergii na używane w niej plastry możliwe są również: alergia na substancje używane do przygotowania skóry przed aplikacją plastra oraz alergia na kombinację substancji używanych do produkcji kleju do plastrów do kinesiotapingu oraz substancji używanych do przygotowania skóry przed aplikacją plastra. Stanowi to bardzo ważny obszar badań, ponieważ alergia może powodować poważne uszkodzenia skóry i rany. U pacjentów z porażeniem lub w śpiączce ostre alergie mogą doprowadzić do poważnych ran, a nawet odleżyn.
EN
Kinesiology taping is currently regarded as an independent or supporting method in rehabilitation, orthopaedics and sport medicine. The idea of the method lies in the effect of elastic tape applied according to the kinesiolgy taping rules. Kinesio tape, made from cotton and acrylic, has parameters (thickness, weight, extensibility, etc.) very similar to those of human skin. Glue used in kinesio tex tape is hypoallergenic. Evidence of allergy during kinesiology taping treatment (heat, rash etc.) in clinical practice is rare, there is a lack of articles in this area. The aim of the present article is to familiarize one with an interesting case of allergy during kinesiology taping treatment and to speculate on the potential implications of this possibility in kinesio taping treatment for clinical practice. Further study is recommended to determine the source(s) of the allergy. The case presented case could constitute evidence that during kinesio taping treatment apart from the possibility of allergy to the kinesiology tape itself there is equally possible: allergy to substances used for skin preparation before kinesio tape application, allergy to a combination of substances used to produce the glue on the kinesio tape and substances used in skin preparation prior to application. This is a very important area of research, because an allergy can cause severe cutaneous lesions and wounds. In patients with paralysis or a coma acute allergies can lead to serious wounds and even bedsores.
EN
Because of the high prevalence of hormone use and reproductive surgeries in Western women natural menopause is a less frequent condition. Our aim was to examine the influences of hormonal and other factors on timing of cessation of menses. We analysed population controls of a German case-control study on breast cancer risks. The sample comprised N=829 women without hysterectomy or bilateral oophorectomy. We estimated the risk for the occurrence of last menses by Cox proportional hazard modelling. For calculating hazard rate ratios (HRR) and 95% confidence intervals (CI) women with menstrual cycles up to one year before interview were censored at that age. Median age at cessation of menses was 50 years (inter-quartile range 47–53 years). A significant later cessation of menses resulted from oral contraceptive use (HRR 0.74, 95% CI 0.59–0.93 for up to 10 years), and hormone therapy use until last menses (HRR 0.57, 95% CI 0.47–0.70). Also, thyroidal medications were associated with a delayed cessation of menses (HRR 0.64, 95% CI 0.42–0.96 for more than 10 years of use). Smoking until at least two years before last menses and allergies revealed an earlier cessation of bleedings (HRR 1.50, 95% CI 1.22–1.83 and HRR 1.28, 95% CI 1.07–1.53 respectively). Natural menopause is difficult to determine. Factors affecting the ovaries or the endocrine system can modulate timing of menopause. Endocrine biomarkers should be additionally taken into account when defining menopausal status.
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.