This paper takes into consideration two PMSM motors of size 80 with very similar efficiency and output power. In the article, design differences between a classic 4 pole/24 tooth motor with distributed winding and a 10 pole/12 tooth motor with concentrated winding are shown. Calculations and tests results are also presented for both machines.