EN
There has been a rise in the use of sonographic urethrocystography in patients with a full bladder. So far, no publications have been made on the analysis of repeatability and reproducibility of the measurements performed during this procedure. Aim: An assessment of repeatability and reproducibility of urethral length measurements during sonographic urethrocystography in females with a full bladder in the introital approach, using real-time two-dimensional transvaginal ultrasound. Material and methods: The ultrasound was performed in accordance with a standardized technique in female patients with a full bladder containing 200–300 mL of liquid. A total of 92 patients were included in the analysis. Results: The Intraclass Correlation Coefficient for repeatability and reproducibility of urethral length measurements in sonographic urethrocystography ranged between 0.9217 and 0.9873 (p = 0.0000). The analysis of ultrasound urethral length measurements taken by two different physicians at an interval of several months confirmed their very high compatibility (ICC = 0.81, p = 0.000). Conclusions: Very good repeatability and reproducibility of urethral length findings during sonographic urethrocystography performed in accordance with the presented technique support the possible use of this type of examination in both clinical practice and research.
PL
Ultrasonograficzna uretrocystografia u pacjentek z wypełnionym pęcherzem moczowym jest coraz częściej stosowana. Nie opublikowano do tej pory analizy powtarzalności pomiarów zdejmowanych podczas tego badania. Cel pracy: Ocena powtarzalności i odtwarzalności pomiarów długości cewki moczowej podczas ultrasonograficznej cystouretrografii, wykonywanej u kobiet w czasie rzeczywistym, przezprzedsionkowo, głowicą przezpochwową w prezentacji dwuwymiarowej, z wypełnionym pęcherzem moczowym. Materiał i metody: Badanie ultrasonograficzne wykonywano zgodnie z wystandaryzowaną techniką u pacjentek z wypełnionym pęcherzem moczowym, zawierającym 200–300 ml płynu. Analizą objęto wyniki uzyskane od 92 chorych. Wyniki: Współczynnik ICC powtarzalności oraz odtwarzalności pomiarów długości cewki moczowej w ultrasonograficznej uretrocystografii wahał się od 0,9217 do 0,9873, p = 0,0000. Analiza pomiarów ultrasonograficznej długości cewki, wykonanych przez dwóch różnych lekarzy w odstępie kilku miesięcy, potwierdziła ich zgodność na bardzo dobrym poziomie (współczynnik korelacji wewnątrzklasowej = 0,81 przy p = 0,000). Wnioski: Bardzo dobra powtarzalność i odtwarzalność wyników pomiarów długości cewki moczowej podczas ultrasonograficznej uretrocystografii, uzyskanej zgodnie z opisaną techniką, stanowią potwierdzenie możliwości zastosowania tego badania w praktyce klinicznej i w badaniach naukowych.
EN
Introduction: Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study: The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods: The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results: The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions: Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes.
PL
Wstęp: Implanty stosowane do leczenia pacjentek z dolegliwościami uroginekologicznymi są dobrze widoczne w badaniu ultrasonograficznym. Lokalizacja taśmy podcewkowej określana jest w stosunku do cewki moczowej oraz spojenia łonowego. Cel pracy: Celem pracy była ocena dokładności pomiarów określających lokalizację taśmy podcewkowej uzyskanych podczas badania ultrasonograficznego dna miednicy wykonywanego głowicą przezpochwową. Materiał i metody: Analizą objęto wyniki pomiarów ultrasonograficznych przeprowadzonych zgodnie z wystandaryzowaną techniką u kobiet, które zostały skierowane na diagnostykę uroginekologiczną. Do analizy powtarzalności i odtwarzalności wyników uzyskanych tego samego dnia wykorzystano dane od 68 pacjentek. Wyniki: Współczynnik korelacji wewnątrzklasowej dla powtarzalności oraz odtwarzalności pomiarów lokalizacji taśmy podcewkowej uzyskanych w badaniu ultrasonograficznym głowicą przezpochwową wahał się od 0,6665 do 0,9911. Analiza pomiarów lokalizacji taśmy podcewkowej potwierdziła ich zgodność na bardzo dobrym i dobrym poziomie. Wnioski: Bardzo dobra i dobra powtarzalność oraz odtwarzalność pomiarów lokalizacji taśmy podcewkowej uzyskanych w badaniu ultrasonograficznym dna miednicy wykonywanym głowicą przezpochwową stanowią potwierdzenie możliwości zastosowania tego badania w praktyce klinicznej i w badaniach naukowych. Artykuł w wersji polskojęzycznej jest dostępny na stronie http://jultrason.pl/index.php/wydawnictwa/volume-17-no-69