Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl
Preferences help
enabled [disable] Abstract
Number of results

Results found: 3

Number of results on page
first rewind previous Page / 1 next fast forward last

Search results

help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
EN
Convergence excess esotropia is commonly treated with corrective glasses (plus lenses), which reduces the angle of deviation for a distance, but the near deviation is still observed. Two types of approach are used to manage convergence excess esotropia: bifocals or eye muscles surgery. Nevertheless, both treatments seem to fail to influence the stereovision. The paper describes the case of 10-year-old girl, diagnosed with convergence excess esotropia with high AC/A ratio, who was subjected to the optometric vision therapy and bifocals. As an effect, visual parameters were improved, and majority of visual symptoms decreased. This case indicates that treatment plan for esotropia should include improvement of accommodation, eye movements and inter-ocular suppression, what strongly influence oculo-motor control and stereovision.
PL
Akomodacyjna ezotropia z nadmierną konwergencją jest stanem, w którym korekcja nadwzroczności redukuje kąt zeza do dali, natomiast w bliży oczy pozostają ustawione w zezie zbieżnym. Wśród metod korekcji zeza tego typu można wyróżnić zastosowanie okularów dwuogniskowych oraz zabieg chirurgiczny na mięśniach okoruchowych. Jednak skuteczność obu tych podejść w uzyskaniu widzenia stereoskopowego pozostaje wątpliwa. Niniejsza praca opisuje przypadek 10-letniej pacjentki z akomodacyjną ezotropią z wysokim ułamkiem AC/A, u której zastosowana optometryczna terapia wzroku wspomagana korekcją dwuogniskową znacząco poprawiła funkcję widzenia oraz zredukowała symptomy wzrokowe. Przypadek ten pokazuje, że w postępowaniu ze stanami zezowymi bardzo istotne jest wyprowadzenie zaburzeń akomodacyjnych i okoruchowych oraz tłumienia międzyocznego, co pozwala na uzyskanie lepszej kontroli okulomotorycznej i widzenia stereoskopowego.
EN
Aim: To evaluate the impact of cataract on color vision detection using an anomaloscope. Methods: 12 patients aged 64–82 years with history of cataract surgery in one eye and mature cataracts in the other eye were examined for color vision using the Rayleigh and the Moreland anomaloscope tests. Results: Different patterns of blue and green color vision deterioration have been observed in the eye with cataract as compared to the IOL eye. A decrease in M1 to approximately 1 (the minimum of the Moreland test scale) was observed in 5 out of 12 participants, whereas an increase in M2 to 99 (the maximum of the Moreland test scale) was observed in 6 out of 12 subjects. R1 found in the Rayleigh test was significantly lower in the cataract eyes as compared to the IOL eyes (38.9 ± 2.3 vs. 43.4 ± 1.6; p < 0.001). Conclusions: It has been shown that cataract causes a decrease in color sensitivity, especially affecting green and blue colors. Following IOL implantation, the previously deteriorated vision of green and blue was clearly improved. The most valuable parameters of the anomaloscope test, which enable to determine cataract severity, were M1, M2 and R1.
EN
The aim of the present study was to assess whether soft multifocal contact lens (SMFCLs) with high addition powers, designed for myopia control, may have an impact on eye movements and eye–hand coordination. A total of 24 young adults used SMFCLs (Relax, SwissLens) with high additions: +2D (Add2) and +4D (Add4). Single vision (Add0) contact lenses were used as controls (Orbis, SwissLens). In the eye–hand coordination task, the study participants were asked to point out the small circle displayed on a touch screen. Reaction time and accuracy of pointing, as well as latency of eye movements were measured. Results showed that SMFCLs had no significant impact on the latency of eye movements (135, 136, 139 ms, for Add0, Add2 and Add4, p = 0.171), reaction time (732, 730, 727 ms for Add0, Add2 and Add4, p = 0.932) or percent error (17%, 13%, 18% for Add0, Add2 and Add4, p = 0.386).
PL
Celem zaprezentowanych badań było sprawdzenie, czy miękkie multifokalne soczewki kontaktowe z wysokimi addycjami o konstrukcji przeznaczonej do kontroli krótkowzroczności mogą wpływać na ruchy oczu i koordynację oko–ręka. W badaniu wzięło udział 24 młodych dorosłych, którym zaaplikowano miękkie multifokalne soczewki kontaktowe (Relax, SwissLens) z addycją +2D (Add2) i +4D (Add4) oraz kontrolne soczewki jednoogniskowe (Add0, Orbis, SwissLens). Zadaniem uczestników było sięganie w kierunku kółka wyświetlanego na ekranie dotykowym. Mierzono czasy reakcji, dokładność dotknięcia celu oraz latencje ruchów oczu. Wyniki wykazały, że miękkie multifokalne soczewki kontaktowe nie wpłynęły na latencje ruchów oczu (135, 136 i 139 ms odpowiednio dla Add0, Add2 i Add4, p = 0,171), czasy reakcji (732, 730, 727 ms dla Add0, Add2 i Add4, p = 0,932) ani na procent błędów (17%, 13%, 18% dla Add0, Add2 i Add4, p = 0,386)
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.