Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl
Preferences help
enabled [disable] Abstract
Number of results

Results found: 4

Number of results on page
first rewind previous Page / 1 next fast forward last

Search results

help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
|
2012
|
vol. 12
|
issue 51
402-419
EN
The aim of this study was to evaluate the diagnostic value of the ultrasound B-mode imaging in the differentiation diagnostics of solid lesions in the breast in relation to the pathomorphological verification. From January to July 2010, 375 ultrasound breast examinations were conducted. The study enrolled 80 women aged 17–83, with 99 solid, focal lesions present in breasts, which were qualified for pathomorphological verification on the basis of the ultrasound examination. All patients underwent: the interview, physical examination, ultrasound examination and sonoelastography. The ultrasound features of the lesions, their vascularization patterns in the Doppler examination as well as the adjacent tissues were determined. Next, the focal lesions were categorized according to the BIRADS-US classification. The obtained results were analyzed statistically. In the group of 80 patients, 99 focal, solid lesions in breasts were visualized, including 39 neoplastic, malignant lesions (group I) and 60 lesions of benign nature (group II). The malignant lesions were often characterized by: greater size, irregular shape (34/39), prevalence of the anteroposterior dimension over the lateral‑lateral dimension (22/39), acoustic shadowing (20/39), the margins not well-circumscribed (37/39), spiculated margins (16/39) and the presence of calcifications (14/39). The benign lesions were much more often hyper- and isoechogenic (14/60). In group I the lesions more often demonstrated the features of increased vascularization (29/39) and the presence of irregularly shaped vessels (23/29). This vascularization more often originated in the adjacent tissues. In the surroundings of the malignant neoplastic lesions, the presence of edema (16/39) and skin thickening (6/39) occurred more frequently and the abnormal axillary lymph nodes were more often diagnosed. The lesions of group I were assigned to the following BIRADS categories: BIRADS-US 4 (9 lesions) and BIRADS-US 5 (30 lesions). In group II, there was a prevalence of BIRADS-US 3 and 4 categories (58 lesions) and 2 lesions were classified to BIRADS-US 5 category. In the statistical analysis of the models based on BIRADS classification, it was demonstrated that BIRADS 4 showed the highest sum of sensitivity and specificity values of 173.6% in differentiation of the character of focal lesions in the breast (sensitivity 76.92%, specificity 96.67%).
PL
Celem pracy była ocena wartości diagnostycznej badania ultrasonograficznego B‑mode w diagnostyce różnicowej litych zmian ogniskowych w piersiach, w odniesieniu do weryfikacji patomorfologicznej. W okresie od stycznia do lipca 2010 roku przeprowadzono 375 badań ultrasonograficznych piersi. Do badań zakwalifikowano 80 kobiet w wieku od 17 do 83 lat, z obecnością 99 litych zmian ogniskowych w piersiach, u których na podstawie badania ultrasonograficznego ustalono wskazania do weryfikacji patomorfologicznej. U wszystkich pacjentek wykonano: badanie podmiotowe i przedmiotowe, badanie ultrasonograficzne i sonoelastografię. Określano cechy obrazu ultrasonograficznego badanych zmian, ich wzorce unaczynienia w badaniu dopplerowskim oraz tkanki otaczające. Następnie zmianom ogniskowym przydzielano kategorie klasyfikacji BIRADS‑usg. Uzyskane wyniki badań poddano analizie statystycznej. W grupie 80 pacjentek uwidoczniono 99 litych zmian ogniskowych w piersiach, w tym 39 zmian nowotworowych złośliwych (grupa I) i 60 o charakterze łagodnym (grupa II). Zmiany nowotworowe złośliwe znamiennie częściej cechowały się: większymi wymiarami, nieregularnym kształtem (34/39), przewagą wymiaru przednio‑tylnego nad boczno‑bocznym (22/39), obecnością cienia akustycznego (20/39), niewyraźnie odgraniczonych brzegów (37/39), spikularnych (16/39), obecnością zwapnień (14/39). Zmiany łagodne istotnie częściej były hiper‑ i izoechogeniczne (14/60). W grupie I zmiany częściej wykazywały cechy wzmożonego unaczynienia (29/39) oraz obecność naczyń o przebiegu nieregularnym (23/29). Unaczynienie to częściej pochodziło z tkanek otaczających. W otoczeniu zmian nowotworowych złośliwych częściej obserwowano obecność obrzęku (16/39), pogrubienia skóry (6/39), częściej stwierdzano nieprawidłowe węzły chłonne pachowe. Zmianom w grupie I przydzielono kategorie BIRADS‑usg 4 (9 zmian) i BIRADS‑usg 5 (30 zmian). W grupie II dominowały zmiany w kategorii BIRADS‑usg 3 i 4 (58 zmiany), a 2 zmiany przydzielono do kategorii BIRADS‑usg 5. W analizie statystycznej modeli opartych na klasyfikacji BIRADS wykazano, iż BIRADS 4 uzyskał najwyższą wartość sumy czułości i swoistości, wynoszącą 173,6% (czułość 76,92%, swoistość 96,67%) w różnicowaniu charakteru zmian ogniskowych w piersiach.
|
2012
|
vol. 12
|
issue 50
286-298
EN
Sonomammography is often the first additional examination performed in the diagnostics of breast diseases. The development of ultrasound imaging techniques, particularly the introduction of high frequency transducers, matrix transducers, harmonic imaging and finally, elastography, influenced the improvement of breast disease diagnostics. Nevertheless, as in each imaging method, there are errors and mistakes resulting from the technical limitations of the method, breast anatomy (fibrous remodeling), insufficient sensitivity and, in particular, specificity. Errors in breast ultrasound diagnostics can be divided into impossible to be avoided and potentially possible to be reduced. In this article the most frequently made errors in ultrasound have been presented, including the ones caused by the presence of artifacts resulting from volumetric averaging in the near and far field, artifacts in cysts or in dilated lactiferous ducts (reverberations, comet tail artifacts, lateral beam artifacts), improper setting of general enhancement or time gain curve or range. Errors dependent on the examiner, resulting in the wrong BIRADS‑usg classification, are divided into negative and positive errors. The sources of these errors have been listed. The methods of minimization of the number of errors made have been discussed, including the ones related to the appropriate examination technique, taking into account data from case history and the use of the greatest possible number of additional options such as: harmonic imaging, color and power Doppler and elastography. In the article examples of errors resulting from the technical conditions of the method have been presented, and those dependent on the examiner which are related to the great diversity and variation of ultrasound images of pathological breast lesions.
PL
Sonomammografia jest często pierwszym badaniem dodatkowym wykonywanym w diagnostyce chorób piersi. Rozwój technik obrazowania ultrasonograficznego, a zwłaszcza wprowadzenie głowic o wysokich częstotliwościach, głowic matrycowych, obrazowania harmonicznego, wreszcie elastografii, wpłynął na poprawę diagnostyki chorób piersi. Niemniej, tak jak w przypadku każdej metody obrazowania, zdarzają się błędy i pomyłki, wynikające z technicznych ograniczeń metody, z warunków anatomicznych piersi (przebudowa włóknista), z niedostatecznej czułości, a zwłaszcza swoistości. Błędy w diagnostyce ultrasonograficznej piersi można podzielić na niemożliwe do uniknięcia oraz na potencjalnie możliwe do ograniczenia. W pracy przedstawiono najczęściej popełniane błędy, w tym spowodowane obecnością artefaktów wynikających z uśredniania objętościowego w polu bliskim i dalekim, artefaktów w torbielach lub w poszerzonych przewodach mlekowych (rewerberacje, artefakty ogona komety lub artefakty listka bocznego), niewłaściwym ustawieniem ogólnego wzmocnienia lub krzywej wzmocnienia czy zasięgu. Błędy zależne od badającego, skutkujące przydzieleniem zmiany do niewłaściwej klasyfikacji BIRADS‑usg, podzielono na błędnie ujemne i błędnie dodatnie. Wymieniono przyczyny takich wyników. Omówiono sposoby pozwalające zminimalizować liczbę popełnianych błędów, w tym związane z właściwą techniką badania, uwzględniające dane z wywiadu oraz wykorzystanie jak największej liczby dodatkowych opcji, takich jak: obrazowanie harmoniczne, kolorowy dopler i dopler mocy oraz elastografia. W pracy przedstawiono przykłady błędów wynikających z uwarunkowań technicznych metody, zależnych od badającego, które związane są z dużą różnorodnością obrazów ultrasonograficznych zmian patologicznych piersi.
|
2012
|
vol. 12
|
issue 50
245-261
EN
The use of BIRADS classification has been recommended in sonomammography examinations in Poland since the year 2010. It was developed by the Polish Ultrasound Society and published in Ultrasound Examinations Standards of the Polish Ultrasound Society. Standards, based on BIRADS-usg classification, introduced uniformity in breast ultrasound examination descriptions and in the terminology of pathological lesions in breasts. BIRADS-usg classification takes into account breast morphological structure elements and pathological focal lesions in them. It enables the distinction between benign lesions and lesions suspected of being malignant. It contains information on the malignancy risk of focal lesions and proposals of diagnostic-therapeutic algorithms (including biopsy) in relation to lesions of different character. The Polish Ultrasound Society recommends performing prophylactic sonomammography examinations every 12 months in women over the age of 30 because of the increasing breast cancer morbidity in women from all age groups. In this article a spectrum of focal changes in breasts are presented within the relevant BIRADS-usg classification categories. The features of ultrasound morphology, enabling them to be classified to particular categories of BIRADS-usg classification are discussed. Management algorithms which may help clinicians to diagnose breast cancer and to treat it are proposed. Elements of medical history, physical examination, recommended techniques of sonomammography examination performance, technical parameters of ultrasound machine and examination description standards are presented. This article was prepared based on the Ultrasound Examination Standards of the Polish Ultrasound Society which was published in 2011 and updated. It contains numerous pictures visualizing BIRADS-usg classification.
PL
Od 2010 roku w Polsce w badaniach sonomammograficznych obowiązuje stosowanie klasyfikacji BIRADS. Została ona opracowana przez Polskie Towarzystwo Ultrasonograficzne oraz opublikowana w Standardach badań ultrasonograficznych Polskiego Towarzystwa Ultrasonograficznego. Standardy, opierające się na klasyfikacji BIRADS‑usg, wprowadziły ujednolicenie opisów badań ultrasonograficznych piersi oraz terminologii nieprawidłowych zmian w piersiach. Klasyfikacja BIRADS‑usg uwzględnia elementy morfologiczne budowy piersi oraz występujących w nich nieprawidłowych zmian ogniskowych. Pozwala różnicować zmiany łagodne od podejrzanych o złośliwość. Zawiera informacje nt. ryzyka złośliwości zmian ogniskowych oraz propozycje algorytmów diagnostyczno‑terapeutycznych (z uwzględnieniem biopsji) w odniesieniu do zmian o różnym charakterze. Polskie Towarzystwo Ultrasonograficzne rekomenduje wykonywanie profilaktycznych badań sonomammograficznych co 12 miesięcy u kobiet od 30. roku życia, w związku ze wzrastającą zachorowalnością na raka piersi u kobiet we wszystkich grupach wiekowych. W pracy przedstawiono spektrum zmian ogniskowych w piersiach, zaliczanych do poszczególnych kategorii klasyfikacji BIRADS‑usg. Omówiono cechy morfologii ultrasonograficznej zmian, pozwalające na zakwalifikowanie ich do poszczególnych kategorii w klasyfikacji BIRADS‑usg. Zaproponowano algorytmy postępowania, które mogą pomóc klinicystom w rozpoznawaniu raka piersi oraz jego leczeniu. Przedstawiono elementy badania podmiotowego, przedmiotowego, zalecaną technikę wykonywania badania sonomammograficznego, parametry techniczne aparatury oraz standard opisu badania. Praca została przygotowana na podstawie Standardów badań ultrasonograficznych Polskiego Towarzystwa Ultrasonograficznego, które zostały opublikowane w 2011 roku, i zaktualizowana zgodnie z najnowszymi doniesieniami z piśmiennictwa. Zawiera liczne zdjęcia obrazujące klasyfikację BIRADS‑usg.
EN
The authors presents a case of cribriform breast carcinoma in a cyst that clinically imitated an abscess. The case concerns a 71-year-old female patient treated for ankylosing spondylitis, with a positive family history of breast cancer. The patient presented at the surgical clinic for incision of an abscess of the mammary gland localized in the lower inner quadrant that was a consequence of previous trauma to the right breast. The abscess was incised and the serosanguineous contents were evacuated. The wound was drained and antibiotics (Dalacin with Metronidazol) were administered for the period of 10 days. During the treatment, a cutaneous fistula was formed. At the incision site, a hard thickening was palpable (tumor). Core needle biopsy of the clinically palpable tumor was performed and the purulent material from the fistula was collected for a culture test. Complete blood count did not reveal leucocytosis. In accordance with the obtained sensitivity report, the patient was started on antibiotics again. Breast ultrasound performed upon the completion of the antibiotic therapy, in the right breast, revealed two solidcystic oval lesions with thick echogenic walls and blurred margins. Both masses contained dense levels of fluid material and solid polycyclic structures. On sonoelastography, the lesions were heterogeneous with a high Young’s modulus. In the right axillary fossa, ultrasound examination revealed three abnormal lymph nodes enlarged to 31 mm length, which were rounded, hypoechoic and without visible sinuses. Histopathology of the core needle biopsy performed at admittance and after the antibiotic therapy indicated a breast abscess (presence of fibrinous and partly fibrinopurulent material). The mass was finally resected to confirm histopathology. The resected material revealed the presence of an invasive, moderately differentiated cribriform carcinoma, which developed within a cyst, with a 40% necrotic component. Eighteen months after the commencement of treatment, the patient remains under oncological supervision and continues hormonal therapy. There are no signs of relapse or foci of distant metastases. The occurrence of breast carcinoma within an abscess emphasises the need for comprehensive assessment and correlation of the clinical picture with imaging and histopathological findings. It also highlights the necessity to include breast abscess in the differential diagnosis of rare forms of carcinomas.
PL
Przedstawiono przypadek raka sitowatego piersi w torbieli klinicznie imitujący ropień. Dotyczy on 71‑letniej pacjentki leczonej z powodu zesztywniającego zapalenia stawów kręgosłupa, obciążonej rodzinnie rakiem piersi. Kobieta zgłosiła się do poradni chirurgicznej w celu nacięcia ropnia gruczołu piersiowego, zlokalizowanego w kwadrancie dolnym wewnętrznym, który powstał w następstwie urazu prawej piersi. Nacięto ropień, ewakuując treść surowiczo‑krwistą. Ranę zdrenowano oraz włączono antybiotykoterapię (Dalacin z Metronidazolem) na okres 10 dni. W trakcie leczenia doszło do powstania przetoki skórnej. W miejscu po nacięciu ropnia było wyczuwalne twarde zgrubienie (guz). Wykonano biopsję gruboigłową klinicznie wyczuwalnego guza oraz pobrano treść ropną z przetoki na posiew. W badaniu morfologii krwi nie występowała leukocytoza. Włączono ponownie antybiotykoterapię zgodnie z otrzymanym antybiogramem. W badaniu ultrasonograficznym piersi, wykonanym po zakończonej antybiotykoterapii, w prawej piersi uwidoczniono dwie lito‑płynowe owalne zmiany, z obecnością grubych echogennych ścian, o zatartych brzegach. W obu zmianach występowały poziomy zagęszczonej treści płynowej oraz lite struktury o policyklicznych kształtach. W sonoelastografii oceniane zmiany były heterogenne, o wysokich wartościach modułu Younga. W prawym dole pachowym w badaniu ultrasonograficznym stwierdzono trzy nieprawidłowe węzły chłonne, powiększone do 31 mm długości, zaokrąglone, hipoechogeniczne, bez widocznych zatok. Wynik badania histopatologicznego z biopsji gruboigłowej wykonanej przy przyjęciu oraz po zakończonej antybiotykoterapii wskazywał na ropień piersi (opisano obecność mas włóknikowych, częściowo włóknikowo‑ropnych). Dopiero wycięcie całej zmiany celem weryfikacji histopatologicznej ujawniło obecność inwazyjnego, średnio dojrzałego raka sitowatego, który rozwinął się w świetle torbieli, z obszarami martwicy obejmującej około 40% masy guza. Pacjentka po 18 miesiącach od rozpoczęcia leczenia pozostaje pod opieką onkologiczną, kontynuuje hormonoterapię, nie ma nawrotu choroby oraz ognisk przerzutów odległych. Opisany przypadek raka piersi w ropniu wskazuje na potrzebę kompleksowej oceny i korelacji obrazu klinicznego z wynikami badań obrazowych oraz histopatologicznych, a także uwzględniania w diagnostyce różnicowej ropnia piersi rzadko występujących postaci raka.
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.