The article presents the description of measurement methodology of moisture transport in unsaturated porous materials using Time Domain Reflectometry (TDR) technique on the example of measurement of capillary uptake phenomenon in the sample of autoclaved aerated concrete (AAC). In the paper there are presented basic principles of the TDR method as a technique applied in metrology, its potential for measurement of moisture in porous materials like soils and porous building materials. Second part of the article presents the experiment of capillary rise process in the sample of AAC. Within the experiment moisture content was monitored in the sample exposed on water influence. Monitoring was conducted using TDR FP/mts probes. Preparation of the measuring setup was presented in detail. The TDR readouts post-processing, graphical presentations of the obtained results, short discussion and comparison of TDR readouts to gravimetric measurement were also presented.
PL
W artykule przedstawiono opis metodyki pomiaru transportu wilgoci w nienasyconych porowatych materiałach przy wykorzystaniu techniki Time Domain Reflectometry (TDR) na przykładzie pomiarów zjawiska podciągania kapilarnego przez próbkę autoklawizowanego betonu komórkowego. Zaprezentowano podstawowe informacje na temat metody TDR jako techniki stosowanej w metrologii. Omówiono jej potencjał do pomiarów wilgoci w takich ośrodkach porowatych, jak gleby i porowate materiały budowlane. Druga część artykułu przedstawia eksperyment podciągania kapilarnego przez próbkę autoklawizowanego betonu komórkowego. W trakcie trwania eksperymentu monitorowano zmiany wilgotności w próbce wystawionej na oddziaływaniewody. Monitoring realizowano za pomocą sond TDR FP/mts. Rozdział „Materials and Methods” przedstawia szczegółowo przygotowanie stanowiska pomiarowego. W rozdziale „Results” podano odczyty miernika TDR przeliczone na wilgotność oraz zaprezentowano uzyskane wyniki w postaci graficznej. Zawarto w nim również krótką dyskusję wyników i porównanie odczytów TDR z pomiarami grawimetrycznymi.
EN
The article presents information about moisture protection of building materials. The discussed parameters determining the efficiency of the water protection are material porosity, water absorptivity and surface condition of building materials. Moreover the ecological aspect of hydrophobic VOC-free preparations available on the market has been underlined. The first part of the article is a description of moisture problem in the building envelopes and the possibilities of its prevention. The special attention is put on the electric methods of moisture estimation with a special emphasis on the Time Domain Reflectometry (TDR) method. The second part of the article is devoted an experiment of model red-brick walls exhibited on capillary uptake process. For the experiment three model red-brick walls were built and prepared for water uptake process. The experiment was monitored by the capacitive and surface TDR probes thanks to which the necessity of sampling and material destruction could be avoided. Conducted experiments show the progress of water uptake phenomenon in the model walls which differ in type of protection against moisture and prove the potential of the non-invasive measurements using the surface TDR probes. Basic physical parameters of the applied bricks were determined together with the reflectometric measurements. Furthermore, Scanning Electron Microscopy (SEM) was used to analyze the hydrophobic layer continuity.
PL
W artykule przedstawiono parametry materiałów budowlanych, które wpływają na skuteczność stosowania preparatów hydrofobowych. Należą do nich porowatość, nasiąkliwość i stan powierzchni. Podkreślono również ekologiczne aspekty stosowania dostępnych na rynku budowlanym hydrofobowych preparatów wolnych od lotnych związków organicznych. Pierwsza część pracy jest omówieniem problemów wilgotnościowych w przegrodach budowlanych. Duży nacisk położono na elektryczne techniki detekcji wilgoci ze szczególnym uwzględnieniem metody TDR. Druga część ma charakter eksperymentalny. W celu zbadania zjawiska podciągania kapilarnego przygotowano trzy modelowe ścianki z cegły ceramicznej pełnej. Omawiany proces był monitorowany za pomocą czujników pojemnościowych oraz powierzchniowych sond TDR. Uzyskane wyniki pozwalają na śledzenie procesu podciągania kapilarnego w modelowych ściankach z cegły ceramicznej różniących się od siebie rodzajem zastosowanego preparatu hydrofobowego i potwierdzają możliwości sondy powierzchniowej TDR w pomiarach wilgotnościowych murów. Równolegle do badań za pomocą technik elektrycznych wyznaczono podstawowe parametry fizyczne cegły wykorzystanej do wymurowania ścianek, wykonano również zdjęcia za pomocą skaningowego mikroskopu elektronowego (SEM) w celu przeanalizowania ciągłości warstwy hydrofobowej.