Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl
Preferences help
enabled [disable] Abstract
Number of results

Results found: 2

Number of results on page
first rewind previous Page / 1 next fast forward last

Search results

help Sort By:

help Limit search:
first rewind previous Page / 1 next fast forward last
Open Chemistry
|
2011
|
vol. 9
|
issue 5
813-824
EN
Liquid-liquid partition is used in sample preparation and in countercurrent and liquid-liquid chromatographic separations. Partition coefficients are widely used in toxicology, environmental, and analytical chemistry. The K hn determination procedure for the n-hexane/nitromethane system was optimized and partition coefficients for 99 ketones, esters and trimethylsilyl derivatives of phenols, aliphatic and aromatic acids were determined. For 130 compounds, K hn values were predicted using mathematical relationships between K hn and other physicochemical and structural parameters. [...]
Open Chemistry
|
2013
|
vol. 11
|
issue 10
1634-1643
EN
Direct immersion solid-phase microextraction has been optimized and applied to the simultaneous determination of the neutral and basic pharmaceuticals: caffeine, carbamazepine, clomipramine, chlorprothixene and clotrimazole at low concentrations in municipal wastewater. Two absorption type stationary phases: polydimethylsiloxane (PDMS) and polyacrylate (PA) have been found to be most effective for extraction of target analytes. The separation and detection were carried out by gas chromatograph coupled with mass spectrometer working in the selected ion monitoring mode. The method was validated for linearity, detection and quantitation limits, selectivity and precision. The average correlation coefficient of the calibration curves was 0.9933. The LOD values in influent and effluent wastewater were in the range of 10–145 ng L−1 and 4–111 ng L−1, respectively, which were a bit higher than those in the deionized water due to matrix effect. The high values of distribution coefficient (K fs ) in PDMS/water and PA/water systems (log K fs between 3.05 and 4.23) indicates the very high applicability of these stationary phases for determination of carbamazepine, clomipramine, chlorprothixene and clotrimazole in water samples. [...]
first rewind previous Page / 1 next fast forward last
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.