Clinical Evaluation of Near-Infrared Cerebral Oximetry in the Awake-Patient Carotid Endarterectomy

Content

Title variants

Languages of publication

EN

Abstracts

EN
The aim of the study was to evaluate the usefulness of continuous monitoring of regional cerebral oxygen saturation (rSO2) for detection of brain ischemia during carotid endarterectomy.Material and methods. We performed 44 carotid endarterectomies using regional anesthesia, with simultaneous regional cerebral oxygen saturation monitoring in both hemispheres of the brain.Results. Oxygen saturation in the hemisphere ipsilateral to the operated carotid artery dropped from 65.1±8.1 to 58.2±10.7 after carotid artery cross-clamping. The difference was statistically significant (p<0.005). Oxygen saturation in the hemisphere contralateral to the operated artery did not demonstrate a difference between that before or after carotid artery closure (65.7±9.2 and 66.1±10.2, respectively, p=0.1). In five patients (11.4%) carotid artery clamping was associated with the appearance of neurological deficits. Shunt usage was necessary in four cases; the rSO2 decreased by 19.2±14% in this group. In the group without neurological deficit during carotid clamping, the rSO2 decreased by 9.7±10.3% (the difference between groups with and without neurological deficit was not statistically significant, p=0.5). In patients with a rSO2 drop above 20%, the sensitivity of the cerebral oximetry was 20% and specificity 97.5%, while the negative predictive value was 90.7%.Conclusions. Continuous cerebral oximetry is a simple and non-invasive method of patient monitoring during carotid endarterectomy. The rSO2 decreases significantly after the ICA clamping. The sensitivity of cerebral oximetry in prediction of neurological deficit during the procedure is low. Defining the threshold value of rSO2 decrease after ICA clamping as an indication for shunt was not possible with the results of this study.

Year

Volume

79

Issue

8

Pages

519-525

Physical description

Dates

published
1 - 8 - 2007
online
27 - 11 - 2007

Contributors

  • Department of Cardiovascular and Vascular Surgery, Medical University in Gdańsk
  • Anaesthesiology and Intensive Therapy Unit, Medical University in Gdańsk
  • Department of Cardiovascular and Vascular Surgery, Medical University in Gdańsk
  • Department of Cardiovascular and Vascular Surgery, Medical University in Gdańsk
  • Department of Cardiovascular and Vascular Surgery, Medical University in Gdańsk
  • Department of Cardiovascular and Vascular Surgery, Medical University in Gdańsk
  • Department of Cardiovascular and Vascular Surgery, Medical University in Gdańsk
author
  • Department of Cardiovascular and Vascular Surgery, Medical University in Gdańsk

References

  • Ferguson GG, Eliasziw M, Barr HW et al.: The North American Symptomatic Carotid Endarterectomy Trial: surgical results in 1415 patients. Stroke 1999; 30: 1751-58.
  • MRC European Carotid Surgery Trial: interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis. European Carotid Surgery Trialists' Collaborative Group. Lancet 1991; 337: 1235-43.
  • Halsey JH, Jr: Risks and benefits of shunting in carotid endarterectomy. The International Transcranial Doppler Collaborators. Stroke 1992; 23: 1583-87.
  • Jobsis FF: Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science 1977; 198: 1264-67.
  • Samra SK, Dy EA, Welch K et al.: Evaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy. Anesthesiology 2000; 93: 964-70.
  • Beese U, Langer H, Lang W et al.: Comparison of near-infrared spectroscopy and somatosensory evoked potentials for the detection of cerebral ischemia during carotid endarterectomy. Stroke 1998; 29: 2032-37.
  • Mason PF, Dyson EH, Sellars V et al.: The assessment of cerebral oxygenation during carotid endarterectomy utilising near infrared spectroscopy. Eur J Vasc Surg 1994; 8: 590-94.
  • Vernieri F, Tibuzzi F, Pasqualetti P et al.: Transcranial Doppler and near-infrared spectroscopy can evaluate the hemodynamic effect of carotid artery occlusion. Stroke 2004; 35: 64-70.
  • Carlin RE, McGraw DJ, Calimlim JR et al.: The use of near-infrared cerebral oximetry in awake carotid endarterectomy. J Clin Anesth 1998; 10: 109-13.
  • Samra SK, Dorje P, Zelenock GB et al.: Cerebral oximetry in patients undergoing carotid endarterectomy under regional anesthesia. Stroke 1996; 27: 49-55.
  • de Letter JA, Sie HT, Thomas BM et al.: Nearinfrared reflected spectroscopy and electroencephalography during carotid endarterectomy - in search of a new shunt criterion. Neurol Res 1998; 20 (Suppl 1): S23-S27.
  • Connolly JE: Carotid endarterectomy in the awake patient. Am J Surg 1985; 150: 159-65.
  • Mille T, Tachimiri ME, Klersy C et al.: Near infrared spectroscopy monitoring during carotid endarterectomy: which threshold value is critical? Eur J Vasc Endovasc Surg 2004; 27: 646-50.
  • Hirofumi O, Otone E, Hiroshi I et al.: The effectiveness of regional cerebral oxygen saturation monitoring using near-infrared spectroscopy in carotid endarterectomy. J Clin Neurosci 2003; 10: 79-83.
  • Benjamin ME, Silva MB, Jr., Watt C et al.: Awake patient monitoring to determine the need for shunting during carotid endarterectomy. Surgery 1993; 114: 673-79.
  • Rigamonti A, Scandroglio M, Minicucci F et al.: A clinical evaluation of near-infrared cerebral oximetry in the awake patient to monitor cerebral perfusion during carotid endarterectomy. J Clin Anesth 2005; 17: 426-30.
  • Cuadra SA, Zwerling JS, Feuerman M et al.: Cerebral oximetry monitoring during carotid endarterectomy: effect of carotid clamping and shunting. Vasc Endovascular Surg 2003; 37: 407-13.

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.-psjd-doi-10_2478_v10035-007-0081-z
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.