Ionisation Chambers Containing Boron as Neutron Detectors in Mixed Radiation Fields

Content

Title variants

Languages of publication

EN

Abstracts

EN
The paper presents a newly designed ionisation chambers containing boron, operated in the initial recombination regime. The chambers were either filled with BF3 or the chamber electrodes were covered with B4C. The chambers can be placed in paraffin moderators. The sensitivity of the chambers was investigated depending on gas pressure, moderator thickness and polarizing voltage. The results showed that it was possible to obtain nearly the same sensitivity of the chamber to H* (10) for photons and neutrons in restricted energy range, however further investigations are needed to make an optimum design. The examples of applications for dosimetric measurements in mixed radiation fields near medical linear accelerator and in the vicinity of high-energy proton accelerator are presented.

Publisher

Year

Volume

13

Issue

2

Pages

79-91

Physical description

Dates

published
1 - 1 - 2007
online
30 - 12 - 2008

Contributors

  • Institute of Atomic Energy, PL 05-400 Otwock-Świerk, Poland
author
  • Institute of Atomic Energy, PL 05-400 Otwock-Świerk, Poland
  • Institute of Atomic Energy, PL 05-400 Otwock-Świerk, Poland

References

  • Bakewicz E, Budzanowski A, Taraszkiewicz T. AIC-144 cyclotron: present status. Nukleonika 2003; 48(Suplement 2): 117-121.
  • Bartlett DT, Tanner RJ, Tagziria H, Thomas DJ. Response characteristics of neutron survey instruments. 2002, NRPB-R333.
  • Golnik N, Kamiński P, Zielczyński M. A measuring system with a recombination chamber for neutron dosimetry around medical accelerators. Radiat. Prot. Dosim. 2004; 110: 271-276.
  • Golnik N, Tulik P, Zielczyński M. Recombination methods for boron neutron capture therapy dosimetry. Report IAE 98/A 2003.
  • Tulik P, Golnik N, Zielczyński M., Recombination chambers filled with different gases - studies of possible application for BNCT beam dosimetry. Radiat. Prot. Dosim. 2004; 110: 827-831.
  • Zielczyński M, Golnik N. Recombination Ionisation Chambers (in Polish), 2000, Świerk: Institute of Atomic Energy.
  • Zielczyński M, Golnik N, Rusinowski Z. A computer controlled ambient dose equivalent meter based on a recombination chamber. Nucl Instr Meth, Phys Res A 1996; 370: 563-567.