Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results
2017 | 132 | 3 | 535-537

Article title

An Efficient Inductive Coil Link Design for Wireless Power Transfer to Visual Prostheses

Authors

Content

Title variants

Languages of publication

EN

Abstracts

EN
Powering therapeutic devices plays a crucial role in the design phase of implantable electronic units. Batteries could not provide sufficient charge storage, used for the lifetime of the device, considering the space available for them. As sophisticated surgical procedures are required with the possible trauma to the patient such as material discrepancy and tissue damage, replacement is quite risky and not an option. Thus, therapeutic devices, especially visual prostheses, receive power wirelessly through inductive coil links which are connected to a battery outside the body. An inductive link is based on the main principle that there are two components such as primary and secondary units. Although primary unit includes the battery outside the body, power transmitter, and control unit, secondary unit under the skin contains amplifier, rectifier regulators, and power control unit. In this study, an inductive coil link is modelled to evaluate fundamental design specifications for visual prostheses. Inductive coil link parameters are quantitatively investigated so that maximum power transfer efficiency and miniaturization, which are critically important for electronics placed in intraocular region, are provided. Considering 20 mm distance, it is concluded that the separation and the size of the coil pair, loop diameter, frequency have a major role to determine the system performance.

Year

Volume

132

Issue

3

Pages

535-537

Physical description

Dates

published
2017-09

Contributors

author
  • Gazi University, Department of Electrical-Electronics Engineering, Ankara, Turkey
author
  • Gazi University, Department of Electrical-Electronics Engineering, Ankara, Turkey

References

  • [1] M.E. Celik, I. Karagoz, Acta. Phys. Pol. A 128, B-297 (2015), doi: 10.12693/APhysPolA.128.B-297
  • [2] J.C. Schuder, H.E. Stephenson, Jr., IEEE Trans. Biomed. Eng. BME-12, 154 (1965), doi: 10.1109/TBME.1965.4502372
  • [3] J.W. Fuller, IEEE Trans. Biomed. Eng. BME-1, 63 (1968), doi: 10.1109/TBME.1968.4502534
  • [4] C.F. Andren, M.A. Fadali, V.L. Gott, S.R. Topaz, IEEE Trans. Biomed. Eng. BME-15, 278 (1968), doi: 10.1109/TBME.1968.4502578
  • [5] Y. Ahmed, T. Hadjersi, R. Chaoui, Acta. Phys. Pol. A 130, 385 (2016), doi: 10.12693/APhysPolA.130.385
  • [6] J. Hirai, T.W. Kim, A. Kawamura, IEEE Trans. Industr. Electron. 46, 349 (1999), doi: 10.1109/41.753774
  • [7] D. Karayel, V. Yegin, Acta. Phys. Pol. A 130, 272 (2016), doi: 10.12693/APhysPolA.130.272
  • [8] A. Esser, H.C. Skudelny, IEEE Trans. Industr. Appl. 27, 872 (1991), doi: 10.1109/IAS.1990.152344

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.bwnjournal-article-appv132n3p035kz
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.