PL EN


Preferences help
enabled [disable] Abstract
Number of results
- |
Article title

Reliability of glued timber roofs belonging to CC3 class consequences of failure

Content
Title variants
Languages of publication
PL
Abstracts
PL
The arenas with great grandstands are the public places where the consequences of failure are very high. For this reason, according to EN 1990, they belong to CC3 class consequences of failure. The reliability class RC3 is associated with the consequences class CC3 and is defined by the reliability index β = 4.3 with probability of failure pf = 8,54*10–6. The distributions of horizontal and shear resistance within glued timber body – bolts will be described depending on material characteristics of glued timber body and bolts components. The paper will present methods of timber structural design belonging to CC3 consequences failure class.
Publisher
Year
-
Physical description
Dates
online
2015-06-22
Contributors
References
Document Type
Publication order reference
Identifiers
YADDA identifier
bwmeta1.element.ojs-nameId-6e3e8ea9-5a94-37a7-828b-e6cd5da23db6-year-2015-article-2545
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.