Distributions of the <heat transfer coefficient> in <systems aqueous> <solutions CMC-air> were experimentally evaluated along the wall of the jacketed, baffled nonstandard stirred tank equipped with two Rushton disc turbines. Local values of the heat transfer coefficient were measured by means of a special <heat flux meter>. Measurements were carried out for stirred tank with inner diameter D+0.3 m (liquid height in the tank H=2D). Results of the investigations were approximated analytically.