Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results
2017 | 131 | 4 | 1180-1182

Article title

Magnetic Amorphous Micro-Force Sensor

Content

Title variants

Languages of publication

EN

Abstracts

EN
In this paper the innovative method of microforce measurement based on air gap influence on magnetic circuits properties is presented. Magnetic ribbon core with air gap is put under transverse compressive stress perpendicular to the magnetic field direction generated by low-mass calibration weight. Change of the air gap induced by the force acting on the core causes change of its magnetic parameters. The possibility of utilization of various magnetic amorphous materials is investigated. Obtained results indicate a possibility of application of the developed sensor in microforce measurements.

Keywords

EN

Contributors

author
  • Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, sw. A. Boboli 8, 02-525 Warsaw, Poland
author
  • Industrial Research Institute for Automation and Measurements, Al. Jerozolimskie 202, 02-486 Warsaw, Poland
author
  • Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, sw. A. Boboli 8, 02-525 Warsaw, Poland
author
  • Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, sw. A. Boboli 8, 02-525 Warsaw, Poland
  • Faculty of Civil Engineering and Geodesy, Military University of Technology, ≥n. S. Kaliskiego 2, 00-908 Warsaw, Poland

References

  • [1] Handbook on Experimental Mechanics, Ed. A.S. Kobayashi, Prentice-Hall, Englewood Cliffs (NJ) 1993
  • [2] G. Gautschi, Piezoelectric Sensors, Springer, Berlin 2002, Ch. 5, p. 73, doi: 10.1007/978-3-662-04732-3_5
  • [3] S.S. Rao, M. Sunar, Appl. Mech. Rev. 4, 113 (1994), doi: 10.1115/1.3111074
  • [4] S. Dabrowski, P. Bazydlo, R. Szewczyk, in: Progress in Automation, Robotics and Measuring Techniques, Eds. R. Szewczyk, C. Zielinski, M. Kaliczyńska, Springer, Berlin 2015, p. 49, doi: 10.1007/978-3-319-15835-8_6
  • [5] P. Nowak, A. Juś, R. Szewczyk, R. Pijarski, M. Nowicki, W. Winiarski, in: Mechatronics - Ideas for Industrial Application, Eds. J. Awrejcewicz, R. Szewczyk, M. Trojnacki, M. Kaliczynska, Springer, Berlin 2015, p. 345, doi: 10.1007/978-3-319-10990-9_32
  • [6] J. Salach, A. Bienkowski, R. Szewczyk, J. Magn. Magn. Mater. 316, 607 (2007), doi: 10.1016/j.jmmm.2007.03.035
  • [7] A. Bienkowski, R. Szewczyk, J. Salach, Acta Phys. Pol. A 118, 1008 (2010), doi: 10.12693/APhysPolA.118.1008
  • [8] A. Bienkowski, R. Szewczyk, T. Kulik, J. Ferenc, J. Salach, J. Magn. Magn. Mater. 304, 624 (2006), doi: 10.1016/j.jmmm.2006.02.196
  • [9] J. Bydzovsky, L. Kraus, P. Svec, M. Pasquale, J. Magn. Magn. Mater. 272-274, 1743 (2004), doi: 10.1016/j.jmmm.2003.12.414
  • [10] H. Chiriac, M. Pletea, E. Hristoforou, Mater. Sci. Eng. A 375-377, 1024 (2004), doi: 10.1016/j.msea.2003.10.045
  • [11] J.M. Barandiaran, J. Gutierrez, Sens. Actuat. A 59, 38 (1997), doi: 10.1016/S0924-4247(97)80145-8

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.bwnjournal-article-appv131n4187kz
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.