Title variants
Languages of publication
Abstracts
In this study, general characteristics of imbalance problem in electric motor and centrifugal pumps and the vibrations caused by these faults are discussed. The fact that frequencies would yield vibrations which were caused by imbalance problems was investigated in detail. In addition, the vibration behavior formed by the electric motor and centrifugal pump running in water pumping mode are presented as a sample case. It is observed that the imbalance problem which have occurred in the electric motor and centrifugal pump could be easily determined using the vibration analysis.
Keywords
Journal
Year
Volume
Issue
Pages
487-491
Physical description
Dates
published
2016-07
Contributors
author
- SASKİ General Directorate, Kentpark İçi, PK 144, Sakarya
References
- [1] N. Aktürk, R. Gohar, Proc. Instn. Mech. Engrs. 212, 101 (1998), doi: 10.1243/1350650981541921
- [2] J. Piotrowski, Why Shaft Misalignment Continues To Befuddle And Undermine Even The Best CBM And Pro-Active Maintenance Programs, http://www.maintenanceresources.com, 2001
- [3] B. Leimkuhler, Vibration Monitoring of Electric Motor Bearing, SKF Condition Monitoring, Inc. Technical Paper CM1007, 1999
- [4] S. Orhan, Teknoloji 3, 41 (2003)
- [5] W. Victor, Machinery Vibration Measurement and Analysis, McGraw Hill Book Company, 1991
- [6] J.I. Taylor, The Vibration Analysis Handbook, Vibration Consultants, 1994
- [7] D.W. Gelen, Introduction To Machine Vibration, DLI Engineering Corp., 1993
- [8] R.L. Eshleman, Machinery Vibration Analysis II, Vipress, 1996
- [9] S.R. Bognatz, Alignment of Critical and Noncritical Machines, http://www.bently.com, 2000
- [10] D. Yu, J. Cheng, Y. Yang, Mech. Syst. Signal Proc. 19, 259 (2005), doi: 10.1016/S0888-3270(03)00099-2
Document Type
Publication order reference
Identifiers
YADDA identifier