The aim of the article is to present the developed technique to measure the degree of neovascularisation of the cornea image in visible light. The study used an image sensor attached to a slit lamp. The proposed technique consists in performing segmentation of the color image to enhance blood vessels and setting values of the degree of cornea neovascularisation. Comparison of the indicator before and after treatment of the cornea can objectively assess the effectiveness of the adopted method of treatment.
Military Institute of Medicine, Ophthalmology Department, Szaserów 128, 04-141 Warsaw, Poland
References
[1] R.C. Arffa, Duane's Ophthalmology on CD-ROM, Lippincott Williams & Wilkins Publ., Vol. 64, 2006
[2] Y.S. Rabinowitz, Duane's Ophthalmology on CD-ROM, Lippincott Williams & Wilkins Publ., Vol. 65, 2006
[3] G.K. Klintworth, Corneal Angiogenesis: A Comprehensive Critical Review, Springer-Verlag, New York 1991, pp. 1; 13
[4] M.E. Gegúndez-Arias, A. Aquino, J.M. Bravo, D. Marín, Proc. IEEE Trans. Med. Imag. 31, 2 (2012), doi: 10.1109/TMI.2011.2167982
[5] H. Narasimha-Iyer, J.M. Beach, B. Khoobehi, B. Roysam, Proc. IEEE Trans. Biomed. Eng. 54, 1427 (2007)
[6] M. Usman Akram, S. Farrukh Aneeque, A. Atzaz, S.A. Khan, in: Proc. Int. Conf. on Digital Image Processing, Bangkok 2009, p. 34, doi: 10.1109/ICDIP.2009.70
[7] M. Ben Abdallah, J. Malek, K. Krissian, R. Tourki, in: Proc. 8th Int. Multi-Conf. on Systems, Sousse 2011, p. 1, doi: 10.1109/SSD.2011.5767376
[8] K. Murawski, R. Różycki, P. Murawski, A. Matyja, M. Rękas, Acta Phys. Pol. A 124, 517 (2013), doi: 10.12693/APhysPolA.124.517
[9] P. Versura, V. Profazio, E.C. Campos, Acta Ophthalmol. 88, 246 (2010)
[10] K. Różanowski, K. Murawski, Acta Phys. Pol. A 124, 558 (2013), doi: 10.12693/APhysPolA.124.558
[11] K. Różanowski, K. Murawski, Acta Phys. Pol. A 124, 874 (2013), doi: 10.12693/APhysPolA.124.874
[12] K. Murawski, K. Różanowski, Acta Phys. Pol. A 124, 509, (2013), doi: 10.12693/APhysPolA.124.509
[13] K. Murawski, in: Proc. 15th Int. Conf. on Methods and Models in Automation and Robotics (MMAR), 2010, p. 1, doi: 10.1109/MMAR.2010.5587207
[14] K. Murawski, Przegląd Elektrotechniczny 9, 184 (2010) (in Polish)
[15] M. Dastjerdi, K. Al-Arfaj, N. Nallasamy, P. Hamrah, U. Jurkunas, R. Pineda, D. Pavan-Langston, R. Dana, Arch. Ophthalmol. 127, 381 (2009), doi: 10.1001/archophthalmol.2009.18
[16] D.H. Orth, J.S. Kelley, J.W. Berkow, R.W. Flower, Fluoresce in Angiography and Indocyanine, Vol. 1, Górnicki Wydawnictwo Medyczne, Wrocław 2003, p. 1 (in Polish)
[17] J. Kałużny, A. Mierzejewski, S. Milewski, Research Angiographic Fundus, Vol. 1, 1998, p. 1 (in Polish)
[18] E. Wylęgała, A. Nowińska, S. Teper, Optical Coherence Tomography, Vol. 1, 2010, p. 9 (in Polish)
[19] K. Murawski, T. Arciszewski, K. De Jong, Eng. Comput. 16, 275 (2000), doi: 10.1007/PL00013716
[20] J. Daugman, Proc. IEEE Trans. Circuits Syst. Video Technol. 14, 21 (2004), doi: 10.1109/TCSVT.2003.818350