Reconstruction of Lost Fragments of Signal Received from the Wireless Sensor Measuring Fluid Pressure inside the Eye Ball

Content
Title variants
Languages of publication
EN
Abstracts
EN
The aim of the paper is to present a technique of reconstructing data received from a wireless sensor for measuring intraocular pressure. The algorithm was developed to automatically regenerate samples lost due to fortuitous events in clinical trials. The test consisted in measuring the pressure within 24 h, during which the intraocular pressure curve were determined. The paper also discusses the structure and the physical basis of sensor operation and shows the advantages resulting from its use.
Keywords
EN
Publisher

Year
Volume
127
Issue
6
Pages
1596-1600
Physical description
Dates
published
2015-06
received
2014-05-12
(unknown)
2015-04-24
Contributors
author
  • Military University of Technology, Institute of Teleinformatics and Automatics, S. Kaliskiego 2, 00-908 Warsaw, Poland
author
  • Military University of Technology, Institute of Teleinformatics and Automatics, S. Kaliskiego 2, 00-908 Warsaw, Poland
author
  • Military Institute of Medicine, Ophthalmology Department, Szaserów 128, 04-141 Warsaw, Poland
References
  • [1] K. Murawski, R. Różycki, P. Murawski, A. Matyja, M. Rękas, Acta Phys. Pol. A 124, 517 (2013), doi: 10.12693/APhysPolA.124.517
  • [2] K. Różanowski, K. Murawski, Acta Phys. Pol. A 124, 558 (2013), doi: 10.12693/APhysPolA.124.558
  • [3] K. Różanowski, K. Murawski, Acta Phys. Pol. A 122, 874 (2013) http://przyrbwn.icm.edu.pl/APP/PDF/122/a122z5p21.pdf
  • [4] K. Murawski, K. Różanowski, Acta Phys. Pol. A 124, 509 (2013), doi: 10.12693/APhysPolA.124.509
  • [5] Guidelines for Glaucoma, The Japan Glaucoma Society, Vol. 2, Tokyo 2006 http://ryokunaisho.jp/english/Guidelines_for_Glaucoma.pdf
  • [6] http://www.nice.org.uk/nicemedia/live/12145/43792/43792.pdf, 2014
  • [7] J.H. Shaver, J.H. Shen, A.L. Walker, 26th Ann. Int. Conf. IEEE Eng. Med. Biol. Soc., Vol. 1, San Francisco 2004, p. 2330, doi: 10.1109/IEMBS.2004.1403676
  • [8] M. Fingeret, Primary Care Optometry News 85, 139 (2004), doi: 10.1136/bjo.85.2.139
  • [9] A. McDermott, V. Perez, A. Huang, S. Pflugfelder, M. Stern, C. Baudouin, R. Beuerman, A. Burns, V. Calder, M. Calonge, J. Chodosh, D. Coster, R. Dana, L. Hazlett, D. Jones, S. Kim, E. Knop, D. Li, B. Mitchell, J. Niederkorn, E. Pearlman, K. Wilhelmus, E. Kurie, The Ocular Surface 3, 11 (2005), doi: 10.1016/S1542-0124(12)70238-0
  • [10] H. Brewitt, Research Projects in Dry Eye Syndrome, Vol. 45, Karger, Hannover 2010, doi: 10.1159/isbn.978-3-8055-9419-6
  • [11] http://en.wikipedia.org/wiki/Intraocular_pressure
  • [12] W. Śródka, Biomechanical model of the human eyeball, Vol. 91, Oficyna Wydawnicza Politechniki Wrocławskiej, Wrocław 2010
  • [13] J. Major, M. Gacek, J.P. Szaflik, Okulistyka 1, 52 (2011)
  • [14] https://www.glaucomafoundation.org/diagnosing_and_treating_glaucoma.htm, 2014
  • [15] www.reichert.com/product_details.cfm?skuId=2972&skuTk=1035455555#.VW4Eb9LtlBc, (2014)
  • [16] http://www.sensimed.ch/en/sensimed-triggerfish/sensimed-triggerfish.html, (2014)
  • [17] K. Mansouri, R.N. Weinreb, J.H.K. Liu, doi: PLoS ONE 10, 5:e0125530 (2015), doi:10.1371/journal.pone.0125530
  • [18] http://www.medgadget.com/2013/07/smart-continuous-monitoring-of-the-intra-ocular-pressure-with-the-triggerfish-contact-lens-qa-with-rene-goedkoop-cmo-of-sensimed.html
  • [19] H. Lin, S. Godsill, in: Proc. IEEE Workshop on Applications of Signal Processing to Audio and Acoustics, New Paltz 2005, p. 335, doi: 10.1109/ASPAA.2005.1540237
  • [20] L. Grad, Biuletyn IAiR 31, 79 (2011), (in Polish)
  • [21] W. Kwiatkowski, Methods for automatic pattern recognition, BEL Studio, Warszawa 2007, (in Polish)
  • [22] K. Murawski, T. Arciszewski, K. De Jong, Eng. Comput. 16, 275 (2000), doi: 10.1007/PL00013716
Document Type
Publication order reference
Identifiers
YADDA identifier
bwmeta1.element.bwnjournal-article-appv127n605kz
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.