Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results
2015 | 127 | 4 | 1397-1399

Article title

Porous Silicon Based Humidity Sensor

Authors

Content

Title variants

Languages of publication

EN

Abstracts

EN
Porous silicon (PS) is well known as a photovoltaic material. However, in the last couple of years, research has focused on the use of porous silicon as chemical-biological sensors. This paper discusses the use of PS as an optical humidity sensor. Photo-luminescence (PL) quenching measurements in a controlled humidity atmosphere (mixed Nitrogen gas and water vapor) were performed to test the sensor response towards the water vapor. Surface morphologies of the PS samples were characterized by a scanning electron microscopy (SEM) and structural properties were investigated via Fourier Transform Infrared (FTIR) spectroscopy. It was found that PS surface is very sensitive to the water vapor. The experimental results suggested that PS surface is a promising candidate material to be used as a humidity sensor.

Keywords

EN

Year

Volume

127

Issue

4

Pages

1397-1399

Physical description

Dates

published
2015-04

Contributors

author
  • Kocaeli University, Electro-Optics Systems Eng. Umuttepe, 41380, Kocaeli, Turkey Kocaeli University, LATARUM Laboratory, 41275, Yenikoy, Kocaeli, Turkey Kocaeli University, Hereke MYO, 41800, Hereke-Kocaeli, Turkey

References

  • [1] W.J. Salcedo, F.J.R. Fernandez, J.C. Rubim, Spectrochimica Acta Part A 60, 1065 (2004), doi: 10.1016/S1386-1425(03)00338-X
  • [2] H.J. Kim, Y.Y. Kim, K.W. Lee, Sensor. Actuat. A 165, 276 (2011), doi: 10.1016/j.sna.2010.10.016
  • [3] N.K. Ali, M.R. Hashim, A. Abdul-Aziz, Solid-State Electronics 52, 1071 (2008), doi: 10.1016/j.sse.2008.03.010
  • [4] P. Furjes, A. Kovacs, C. Ducso, M. Adam, B. Muller, U. Mescheder, Sens. Actuators B 95, 140 (2003), doi: 10.1016/S0925-4005(03)00423-4
  • [5] G. Di Francia, A. Castaldo, E. Massera, I. Nasti, L. Quercia, I. Rea, Sens. Actuators B: Chem. 111, 135 (2005), doi: 10.1016/j.snb.2005.06.048
  • [6] M. Rocchia, A.M. Rossi, G. Zeppa, Sens. Actuators B: Chem. 123, 89 (2007), doi: 10.1016/j.snb.2006.07.025
  • [7] M. Li, M. Hu, P. Zeng, S. Ma, W. Yan, Y. Qin, Electrochimica Acta 108, 167 (2013), doi: 10.1016/j.electacta.2013.06.106
  • [8] S. Dhanekar, S.S. Islam, T. Islam, A.K. Shukla, Harsh, Physica E 42, 1648 (2010), doi: 10.1016/j.physe.2010.01.017

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.bwnjournal-article-appv127n4146kz
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.