Article title

Multifunctional, Optical Sensor for Analysis of Dynamic Pupillary Light Reflex

Content
Title variants
Languages of publication
EN
Abstracts
EN
The aim of the publication is to describe the multifunctional optical sensor for analysis of dynamic pupillary light reflex developed by the authors which could be used as an objective indicator of human fatigue. The authors utilized knowledge gained from past experimental studies to develop a sensor, which along with custom software for detection of parameters of dynamic pupillary reflex provides a quick analysis of the human psychophysiological condition. Furthermore, the obtained parameters may also be utilized for medical purposes. The authors present the results of pilot studies prior to the development process of the sensory solution. The obtained result show that the type of light stimulation of the retina has a significant impact on the dynamic parameters of the pupillary reflex. The results played also an important role in shaping the structural assumptions of the sensor, so that it can serve as an indicator of the human fatigue level. The article includes results of experimental research conducted during the testing process of the sensor using various parameters of frequency light excitations, luminance and chrominance.
Keywords
Contributors
  • Military Institute of Aviation Medicine, Aviation Bioengineering Department, Z. Krasińskiego 54, 01-755 Warsaw, Poland
  • Military Institute of Aviation Medicine, Aviation Bioengineering Department, Z. Krasińskiego 54, 01-755 Warsaw, Poland
author
  • Military University of Technology, Institute of Teleinformatics and Automatics, S. Kaliskiego 2, 00-908 Warsaw, Poland
References
  • [1] L.L. Lobato-Rincón, M.C. Cabanillas Campos, J.J. Navarro-Vallas, C. Bonnin-Arias, E. Chamorro, C. Sanchez-Ramos Roda, Adicciones 25, 137 (2013)
  • [2] G.L. Ferrari, J.L.B. Marques, R. Gandhi, S.R. Heller, F.K. Schneider, S. Tesfaye, H.R. Gamba, BioMed. Eng. OnLine 9, 26 (2010), doi: 10.1186/1475-925X-9-26
  • [3] A. Kawasaki, R.H. Kardon, Ophthalmol. Clin. North Am. 14, 149 (2001)
  • [4] R.J. Duffey, D. Leaming, J. Refract. Surg. 21, 87 (2005)
  • [5] I. Loewenfeld, O. Lowenstein, The Pupil: Anatomy, Physiology, and Clinical Applications, Iowa State University Press, 1993
  • [6] D.F. Fotiou, V. Stergioua, D. Tsiptsiosa, C. Litharib, M. Nakouc, A. Karlovasitoua, Int. J. Psychophysiol. 73, 143 (2009), doi: 10.1016/j.ijpsycho.2009.01.011
  • [7] M.Höfle, R. KenntnerMabiala, P. Pauli, G.W. Alpers,Int. J. Psychophysiol. 70, 171 (2008), doi: 10.1016/j.ijpsycho.2008.06.008
  • [8] J.W. McLaren, P.J. Hauri, Siong-Chi Lin, C.D. Harris, Sleep Med. 3, 347 (2002), doi: 10.1016/S1389-9457(02)00017-5
  • [9] A. Kaltsatou, E. Kouidi, C. Lithari, N. Koutlianos, F. Fotiou, A. Deligiannis, Int. J. Psychophysiol. 77, 283 (2010), doi: 10.1016/j.ijpsycho.2010.06.148
  • [10] J.F. Payen, S. Isnardon, J. Lavolaine, P. Bouzat, M. Vinclair, G. Francony, Ann. Fr. AnesthReanim. 31, e155 (2012), doi: 10.1016/j.annfar.2012.04.020
  • [11] B.J. Wilhelm, A. Widmann, W. Durst, C. Heine, G. Otto, Int. J. Psychophysiol. 72, 307 (2009), doi: 10.1016/j.ijpsycho.2009.01.008
  • [12] M. Warga, H. Lüdtke, H. Wilhelm, B. Wilhelm, Vis. Res. 49, 295 (2009), doi: 10.1016/j.visres.2008.09.019
  • [13] K. Różanowski, K. Murawski, Acta Phys. Pol. A 124, 558 (2013), doi: 10.12693/APhysPolA.124.558
  • [14] J.K. de Souza, M.A. Pinto, P.G. Vieira, J. Baron, C.J. Tierra-Criollo, Comput. Meth. Progr. Biomed. 112, 607 (2013), doi: 10.1016/j.cmpb.2013.07.011
  • [15] M.C. Canver, A.C. Canver, K.E. Revere, D. Amado, J. Bennet, D.S. Chung, Comput. Meth. Progr. Biomed. 113, 221 (2014), doi: 10.1016/j.cmpb.2013.08.008
  • [16] K. Yamaji, T. Yoshitomi, S. Usui, Y. Ohnishi, Vis. Res. 43, 479 (2003), doi: 10.1016/S0042-6989(02)00574-6
  • [17] S. Usui, Y. Hirata, Ann. Biomed. Eng. 23, 375 (1995), doi: 10.1007/BF02584438
  • [18] Xiaofei Fan, Gang Yao, IEEE Trans. Biomed. Eng. 58, 37 (2011), doi: 10.1109/TBME.2010.2080678
  • [19] Z. Piotrowski, K. Różanowski, Acta Phys. Pol. A 118, 131 (2010)
  • [20] M. Czarkowski, M. Mikulska, M. Zebrowski, A. Baran, K. Rozanowski, J. Human Hypertens. 18, 293 (2004), doi: 10.1038/sj.jhh.1001667
  • [21] M. Czarkowski, K. Różanowski, Sci. Eng. Ethics 15, 201 (2009), doi: 10.1007/s11948-009-9113-x.
  • [22] M. Życzkowski, K. Różanowski, K. Murawski, M. Karol, P. Markowski, Acta Phys. Pol. A 122, 942 (2012)
  • [23] K. Różanowski, K. Murawski, Acta Phys. Pol. A 122, 874 (2012)
  • [24] K. Murawski, K. Różanowski, M. Krej, Acta Phys. Pol. A 124, 513 (2013), doi: 10.12693/AphysPolA.124.513
  • [25] K. Murawski, K. Różanowski, Acta Phys. Pol. A 124, 509 (2013), doi: 10.12693/AphysPolA.124.509
Document Type
Publication order reference
Identifiers
YADDA identifier
bwmeta1.element.bwnjournal-article-appv127n312kz
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.