Unfocused/Weakly Focused Pressure Pulse Sources for Pain Therapy: Measurements in Water and in a Dry Test Bench

Content

Title variants

Languages of publication

EN

Abstracts

EN
Unfocused/weakly focused pressure pulses (UPP) are generated by an "air-gun" like mechanism, with a projectile accelerated by pressurized air and impinging on a metal applicator. They were introduced in 1998 for the treatment of orthopedic soft tissue pain. The patient side of the applicator (a circular piston of 6-30 mm diameter) releases single pressure pulses of 2-10 MPa and 4-5 μs duration. Up today, there is no standard for the measurement of UPP sources (UPPS), so data are often reported on the basis of the focused lithotripter standard IEC61846. The purpose of this research is to establish methods to reliably measure UPPS acoustic parameters and establish a parameter set based on definitions from focused lithotripsy sources as applicable. Therefore, acoustic characteristics and wave fields of the pressure pulses of UPPS from different manufacturers were measured in a water bath and in a dry test bench. It was demonstrated by comparison with optical hydrophones that piezoelectric hydrophones are appropriate for the measurements of UPP. For on-axis measurements at a fixed distance, measurements in the dry test bench can replace water-bath measurements. Additionally, the dry test bench allows for reliable results at pulse rates >1 Hz.

Keywords

Year

Volume

127

Issue

1

Pages

135-137

Physical description

Dates

published
2015-01

Contributors

author
  • Department Life Sciences/Biomedical Technology, University of Applied Sciences Hamburg, Germany
  • Department Life Sciences/Biomedical Technology, University of Applied Sciences Hamburg, Germany

References

  • [1] C.E. Bachmann, G. Gruber, W. Konermann, F. Ueberle, ESWT and Ultrasound Imaging of the Musculoskeletal System, Springer Book Arch, 2013
  • [2] L. Gerdesmeyer, H. Gollwitzer, P. Diehl, K. Wagner, J. Miner Stoffwechsel 11, 36 (2004)
  • [3] Ching-Jen Wang, J. Orthop Surg. {& Res. 7, 11 (2012), doi: 10.1186/1749-799X-7-11
  • [4] F. Ueberle, A. Jamshidi-Rad, Biomed Tech 57, 700 (2012), doi: 10.1515/bmt-2012-4439
  • [5] IEC 61846 - Pressure pulse lithotripters - Characteristics of fields, International Standard, IEC, Geneva (1998)
  • [6] F. Ueberle, A. Jamshidi-Rad, J. Phys.: Conf. Series 279 012003 (2011), doi: 10.1088/1742-6596/279/1/012003
  • [7] J. Staudenraus, W. Eisenmenger, Ultrasonics 31, 267 (1993), doi: 10.1016/0041-624X(93)90020-Z
  • [8] F Ueberle, A. Jamshidi-Rad, Biomed. Tech. 58, online (2013), doi: 10.1515/bmt-2013-4130