EN
Paper presents the results of investigations of the influence of the tensile stresses on magnetic characteristics of Fe_{80}B_{11}Si_{9} amorphous alloy in as quenched and annealed state. For the tests, a special methodology of application of uniform tensile stresses to the ring shaped sample was developed. Due to special non-magnetic pads, the magnetizing and sensing coils can be wound around the core. Experimental results indicate high stress sensitivity of Fe_{80}B_{11}Si_{9} alloy in both as-quenched and annealed state. Permeability of the core decreases over 64% and 58% for as-quenched and annealed core respectively, especially for lower values of the amplitude of magnetizing field.