Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results
2014 | 125 | 4A | A-7-A-10

Article title

Hand Grip-EMG Muscle Response

Content

Title variants

Languages of publication

EN

Abstracts

EN
One of the most important factors in hand-arm system research is the information about hand grip force and pressing force on a tool handle. This article focuses on an alternative method to measure grip force. For grip force, one of the most popular solutions is a special handle with force sensors. However, when we want to use it with regular hand tool like e.g. a drill, it seems to be uncomfortable because we must interfere in handle construction. A solution proposed in this article is based on technique for evaluating and recording the electrical activity produced by muscles, electromyography (EMG). It has been assumed that EMG signal will be proportional to muscle tension responsible for palm grip. This solution have one significant advantage when comparing to special handle. It can be used with regular tool without interfering in the handle. Measurement presented in this article have been carried out with use of surface electromyography (sEMG). It is not invasive method which enables to measure EMG signal through placing stickers with electrodes directly on a skin.

Keywords

EN

Contributors

author
  • AGH University of Science and Technology, Faculty of Mechanical Engineering and Robotics Department of Mechanics and Vibroacoustics, Al. A. Mickiewicza 30, 30-059 Krakow, Poland
author
  • Narutowicz Specialist Municipal Hospital, Department of Internal Medicine Prądnicka 35-37, 31-202 Kraków, Poland

References

  • [1] C. Disselhorst-Klug, T. Schmitz-Rode, G. Rau, Clinical Biomechanics 24, 225 (2009), doi:10.1016/j.clinbiomech.2008.08.003
  • [2] P. Bartuzi, D. Roman-Liu, Int. J. Occup. Safety Ergon. 18, 233 (2012)
  • [3] P. Bartuzi, T. Tokarski, D. Roman-Liu, Acta Bioeng. Biomech. 12, 87 (2010)
  • [4] R.W. McGorry, Applied Ergonomics 32, 271 (2001), doi:10.1016/S0003-6870(00)00062-4
  • [5] R. Barański W. Batko, Acta Phys. Pol. A 119, 913 (2011)
  • [6] M.W. Dobry, M. Wojsznis, Diagnostic 1, 151 (2004)
  • [7] P. Kowalski, Ph.D. Thesis, Central Institute for Labour Protection - National Research Institute (CIOP-PIB), 2001, p. 111
  • [8] M.A. Książek, J. Tarnowski, Arch. Acoust. 31, 299 (2006)
  • [9] S. Konturek, T. Brzozowski, Human Physiology. General physiology, blood and muscles Vol. I, Wydawnictwo Uniwersytetu Jagiellońskiego, Kraków 2003
  • [10] W. Traczyk, A. Trzebski, Human Physiology with elements of clinical and applied physiology, Wydawnictwo Lekarskie PZWL, Warszawa 2004, (in Polish)
  • [11] P. Konrad, ABC EMG. Practical Introduction of Kinesiological Electromyography, Technomex, !!MIEJSCE!! 2007, (in Polish)
  • [12] P. Gajewski, in: Szczeklik's Internal Medicine, Ed.: P. Gajewski, Medycyna Praktyczna, Gliwice 2012, (in Polish)
  • [13] A. Bochenek, M Reicher, Human Anatomy, Vol. 1, IX(V) Ed., PZWL, Warszawa 1978, (in Polish)
  • [ ] H. Gray, Gray's Anatomy of the Human Body, John W. Parker and Son, West Strand 1858

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.bwnjournal-article-appv125n4a01kz
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.