Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results
2014 | 125 | 2 | 571-573

Article title

Investigating Effects of Testing Parameters on Frictional Heating of UHMWPE by Taguchi Method

Content

Title variants

Languages of publication

EN

Abstracts

EN
Frictional heating makes detrimental effects on surrounding tissue and lubricant around the artificial hip joint. For reduction of this thermal damage, testing parameters and their effects were investigated by using the Taguchi method and analysis of variance. Ultra high molecular weight polyethylene (UHMWPE) acetabular liners and CoCrMo femoral head artificial hip joint components were used as samples. Frictional heating measurements of the joints were carried out on a custom made hip joint friction experimental setup. Surface dimples in different sizes were machined on the inner surface of acetabular insert samples. The tests were conducted under different loading conditions with different testing time. Bovine calf serum was used as lubricant with different amount of third body wear particles in it. Temperature rise in acetabular and femoral component was recorded with embedded thermocouples. The experimental results demonstrated that the surface dimples were the major parameter on frictional heating, followed by applied load, amount of third body particles and time. The optimal combination of the testing parameters was predicted and validated by doing experiments.

Keywords

EN

Year

Volume

125

Issue

2

Pages

571-573

Physical description

Dates

published
2014-02

Contributors

author
  • Department of Mechanical Engineering, Yildiz Technical University, 34349 Besiktas, İstanbul, Turkey
author
  • Department of Interchangeable Manufacturing and Industrial Metrology, Institute for Production Engineering , and Laser Technology, Vienna University of Technology, Karlspl. 13/3113, A-1040 Wien, Austria

References

  • 1. G. Bergmann, F. Graichen, A. Rohlmann, N. Verdonschot, G.H. Van Lenthe, doi: 10.1016/S0021-9290(00)00188-3, J. Biomechan. 34, 421 (2001)
  • 2. G. Bergmann, F. Graichen, A. Rohlmann, N. Verdonschot, G.H. Van Lenthe, doi: 10.1016/S0021-9290(00)00234-7, J. Biomechan. 34, 429 (2001)
  • 3. J.W. Pritchett, doi: 10.1615/JLongTermEffMedImplants.v21.i1.40, J. Long-Term Eff. Med. Impl. 21, 55 (2011)
  • 4. P. Pawlus, L. Galda, A. Dzierwa, W. Koszela, doi: 10.1016/j.wear.2009.03.003, Wear 267, 1873 (2009)
  • 5. W. Koszela, P. Pawlus, L. Galda, doi: 10.1016/j.wear.2007.01.108, Wear 263, 1585 (2007)
  • 6. S.K Young, M.A Lotito, T.S. Keller, doi: 10.1016/S0043-1648(98)00275-0, Wear 222, 29 (1998)
  • 7. I. Nishimura, T. Yuhta, K. Ikubo, T. Shimooka, S. Murabayashi, Y. Mitamura, ASAIO J. 39, 762 (1993)
  • 8. G.N. Dong, M. Hua, J. Li, K.B. Chuah, doi: 10.1016/j.matdes.2006.09.015, Mater. Des. 28, 2402 (2007)
  • 9. ISO 7206-2:2011, Implants for surgery - Partial and total hip joint prostheses, Part 2: Articulating surfaces made of metallic, ceramic and plastics materials
  • 10. ISO 21535:2001, Non-active surgical implants - Joint replacement implants - Specific requirements for hip-joint replacement implants
  • 11. B. Sagbas, M.N. Durakbasa, in: doi: 10.1016/j.measurement.2013.12.020, Measurement , (2014), in press
  • 12. B. Sagbas, M.N. Durakbasa, doi: 10.12693/APhysPolA.123.453, Acta Phys. Pol. A 123, 453 (2013)
  • 13. B. Sağbaş, M.N Durakbaşa, doi: 10.1016/j.wear.2013.03.023, Wear 303, 313 (2013)
  • 14. A. Koyun, M.E. Yurci, B. Sagbas, M.N. Durakbasa, in: 2nd Int. Conf. on Quality and Innovation in Engineering and Management, Cluj-Napoca (Romania), Eds.: S. Popescu, S. Brad, D. Popescu, : Romanian Society for Quality Assurance, Bucharest 2012, p. 379
  • 15. M. Şirvancı, Design of Experiments for Quality Taguchi Approach, Literatür Yayıncılık, İstanbul 1997 (in Turkish)

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.bwnjournal-article-appv125n2130kz
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.