Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results
2013 | 124 | 3 | 558-562

Article title

Optical Sensor to Monitor Pupillary Light Reflex

Content

Title variants

Languages of publication

EN

Abstracts

EN
The aim of the paper is to describe design of an optical sensor intended to analyze pupillary light reflex. It also presents the results of physiological adaptation mechanisms in human eye, i.e. response of the iris to changes in the intensity of light that falls on the retina of the eye under conditions of sensory deprivation. Pupillary light reflex is a closed loop nerve reflex. It controls the amount of light that reaches the retina. Based on the test results, an optical sensor was designed, fabricated and correctly calibrated. In comparative tests with the use of F^2D Fit-For-Duty, a commercial system by AMTech, selected pupillographic parameters were primarily evaluated (baseline pupil diameter, oscillations, reflex latency, maximum reaction time, pupil constriction time, pupil dilation time, and constriction amplitude) under conditions of diminished alertness, reduced ability to concentrate, increasing fatigue, and drowsiness. The solution comes as part of a mobile pupillography device intended to be assembled in cars and airplanes to identify conditions of lower alertness, reduced ability to concentrate, increasing fatigue and drowsiness in drivers, pilots and traffic controllers, and to trigger alarm and preventive measures, if necessary.

Keywords

EN

Contributors

  • Military Institute of Aviation Medicine, Aviation Bioengineering Department, Z. Krasińskiego 54, 01-755 Warsaw, Poland
author
  • Military University of Technology, Institute of Teleinformatics and Automatics, S. Kaliskiego 2, 00-908 Warsaw, Poland

References

  • [1] Ch. Tilmant, M. Charavel, M. Ponrouch, Monitoring and Modeling of Pupillary Dynamics: Study of the Autonomous Nervous System, Blaise Pascal University, OICMS France 2005
  • [2] R.J. Duffey, D. Leaming, J. Refract. Surg. 21, 87 (2005)
  • [3] I. Loewenfeld, O. Lowenstein, Anatomy, Physiology, and Clinical Applications, Iowa State University Press, Ames 1993
  • [4] A. Kawasaki, R.H. Kardon, Ophthalmol. Clin. North Am. 14, 149 (2001)
  • [5] D.F. Fotiou, V. Stergioua, D. Tsiptsiosa, C. Litharib, M. Nakouc, A. Karlovasitoua, Int. J. Psychophysiol. 73, 143 (2009)
  • [6] M. Höfle, R. Kenntner-Mabiala, P. Pauli, G.W. Alpers, J. Psychophysiol. 70, 171 (2008)
  • [7] J.W. McLaren, P.J. Hauri, Siong-Chi Lin, C. Harris, Sleep Medicine 3, 347 (2002)
  • [8] A. Kaltsatou, E. Kouidi, C. Lithari, N. Koutlianos, F. Fotiou, A. Deligiannis, Int. J. Psychophysiol. 77, 283 (2010)
  • [9] B. Wilhelm, A. Widmann, W. Durst, Ch. Heine, G. Otto, Int. J. Psychophysiol. 72, 307 (2009)
  • [10] M. Warga, H. Lüdtke, H. Wilhelm, B. Wilhelm, Vision Res. 49, 295 (2009)
  • [11] O. Lowenstein, R. Feinberg, I.E. Loewenfeld, Investigat. Ophthalmol. 2, 138 (1963)
  • [12] B. Wilhelm, H. Wilhelm, P. Streicher, H. Lüdtke, M. Adler, Wien Med. Wochenschr. 146, 387 (1996)
  • [13] K. Murawski, K. Różanowski, Acta Phys. Pol. A 124, 509 (2013)
  • [14] K. Gut, K. Nowak, Europ. Phys. J. Spec. Top. 154, 89 (2008)
  • [15] K. Murawski, in: Proc. XV Int. Conf. on Methods and Models in Automation and Robotics (MMAR), Międzyzdroje, Warsaw Univ., 2010, p. 356
  • [16] K. Gut, Bull. Pol. Acad. Sci., Techn. Sci. 59, 395 (2011)
  • [17] M. Życzkowski, Acta Phys. Pol. A 122, 933 (2012)
  • [18] K. Murawski, Electrotechn. Rev. 9, 184 (2010)

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.bwnjournal-article-appv124n346kz
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.