Microwave measurement techniques attract attention due to its practical solutions in breast cancer imaging. Early detection of cancer is the purpose of these imaging studies. For these imaging processes, phantoms which reflect the properties of the area to be imaged are produced. The produced homogeneous phantoms are imaged by stepper frequency of radar technology, as the narrow bands are used for heterogeneous mixtures. Phantoms are used since 70's until today. Different methods are experimented for producing phantoms of tissue, muscle, fat, skin, etc. Iron powder, polymer materials, various oils and gelatins used today are the materials used for producing the phantoms. In this study, phantom breast imaging is aimed. Phantoms breast and breast tumor samples are created. For phantoms and tumor samples, reflection and transmittion measurements are done with Network Analyzer in X-Band (8.2-12.4 GHz). Complex permittivity is calculated with Agilent 85071 Material Measurement Software-Fast Method (NIST-iterative method). It was considered breast phantom with tumor model for 3D imagine at 2-3.5 GHz frequency range.

Keywords

EN

Contributors

author
  • Material Institute, Tubitak-Marmara Research Center, Gebze, Kocaeli, Turkey
author
  • Material Institute, Tubitak-Marmara Research Center, Gebze, Kocaeli, Turkey
author
  • Material Institute, Tubitak-Marmara Research Center, Gebze, Kocaeli, Turkey
author
  • Material Institute, Tubitak-Marmara Research Center, Gebze, Kocaeli, Turkey

References

  • [1] A.A. Bakar, A. Abbosh, P. Sharpe, M.E. Bialkowski, Y. Wang, Microwave Opt. Technol. Lett. 53, 1595 (2011)
  • [2] J. Baker, M.D. Janezic, J.H. Grosvenor, Jr., R.G. Geyer, Transmission/Reflection and Short-Circuit Line Methods for Measuring Permittivity and Permeability, NIST Technical Note 1355-R, 236 pages, December 1993
  • [3] S. Ganchev, Material Measurement Techniques and Applications; India presentation; Americas TM Contact Center, January 2006
  • [4] J. Baker, M.D. Janezic, J.H. Grosvenor, Jr., R.G. Geyer, Measurement of the Permittivity and Permeability of Lossy Materials, NIST Technical Note 1536, February 2005
  • [5] S. Ganchev, 85071E Material Measurement Software, Agilent Technologies, Inc. 2006, 2011 Published in USA, October 19, 2011, 5988-9472EN
  • [6] A. Sayıntı, M.Sc. Thesis, Sakarya University, Physics Department, 2010
  • [7] E. Açikalin, O. Atıcı, A. Sayıntı, K. Çoban, H. Erkalfa, Progress in Organic Coatings, in press)
  • [8] http://www2.rohde-schwarz.com/en/service_and_support/Downloads/Application_Notes/?type=20&downid=1989
  • [9] M. Lazebnik, E.L. Madsen, G.R. Frank, S.C. Hagness, Phys. Med. Biol. 50, 4245 (2005)