Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results
2013 | 123 | 2 | 453-455

Article title

Evaluating Frictional Temperature Rise in Sliding Surface of Artificial Hip Joint Materials with Different Loading Conditions

Content

Title variants

Languages of publication

EN

Abstracts

EN
Friction between articulating surfaces cause temperature rise in acetabular cup and femoral head. This heating may influence the rate of wear, fatigue, creep, oxidative degradation of bearing materials and may terminate surrounding tissue. The objective of this study is to determine temperature rise with different applied load for the articulating surfaces of conventional ultra high molecular weight polyethylene (UHMWPE) and vitamin E blended ultra high molecular weight polyethylene (VE-UHMWPE) acetabular components paired with a ceramic femoral component in bovine calf serum lubrication condition. Additionally frictional torque between the bearing surfaces was measured and friction coefficient was calculated. Frictional measurements of the joints were carried out on a custom made hip joint friction simulator. Various levels of static loads were applied on 28 mm diameter prostheses. In flexion-extension plane, a simple harmonic oscillatory motion between ± 24° was applied to the UHMWPE acetabular component. The period of motion was 1 Hz and the tests were run up to 12,000 cycles. Temperature rise in acetabular and femoral component was recorded with embedded thermocouples. The results were compared in terms of UHMWPE and vitamin E blended UHMWPE.

Keywords

EN

Year

Volume

123

Issue

2

Pages

453-455

Physical description

Dates

published
2013-02

Contributors

author
  • Department of Mechanical Engineering, Yildiz Technical University, Istanbul, Turkey
author
  • Department of Interchangeable Manufacturing and Industrial Metrology, Vienna University of Technology, Karlsplatz 13/3113, A-1040 Wien, Austria

References

  • [1] C.C. Hu, J.J. Liau, C.Y. Lung, C.H. Huang, C.K. Cheng, Mater. Sci. Eng. C 17, 11 (2001)
  • [2] Y.-S. Liao, H. McKellop, Z. Lu, P. Campbell, P. Benya, Biomaterials 24, 3047 (2003)
  • [3] Z. Lu, H. McKellop, Proc. Inst. Mech. Eng. Part H: J. Eng. Med. Part H, 211, 101 (1997)
  • [4] G. Bergmann, F. Graichen, A. Rohlmann, N. Verdonschot, G.H. Van Lenthe, J. Biomech. 34, 421 (2001)
  • [5] G. Bergmann, F. Graichen, A. Rohlmann, N. Verdonschot, G.H. Van Lenthe, J. Biomech. 34, 429 (2001)
  • [6] G.N. Dong, M. Hua, J. Li, K.B. Chuah, Mater. Design 28, 2402 (2007)
  • [7] H. Bhatt, T. Goswami, Biomed. Mater. 3, 1 (2008)
  • [8] D. Xiong, S. Ge, Wear 250, 242 (2001)
  • [9] G. Lewis, Biomaterials 22, 371 (2001)
  • [10] S.M. Kurtz, O.K. Muratoglu, M. Evans, A.A. Edidin, Biomaterials 20, 1659 (1999)
  • [11] J.L. Tipper, A.L. Galvin, S. Williams, H.M.J. McEwen, M.H. Stone, E. Ingham, J. Fisher, J. Biomed. Mater. Res. Part A 78A, 473 (2006)
  • [12] C. Vaidya, E. Alvarez, J. Vinciguerra, D.A. Bruce, J.D. DesJardins, Proc. Inst. Mech. Eng. H 225, 1 (2011)
  • [13] S.M. Kurtz, UHMWPE Biomaterials Handbook, 2nd ed., Elsevier Inc., Academic Press, Burlington 2009, p. 227
  • [14] C.A. Jacobs, C.P. Christensen, A.S. Greenwald, H. McKellop, J. Bone Joint Surg. Am. 89, 2779 (2007)
  • [15] L. Bradford, D.A. Baker, J. Graham, A. Chawan, M.D. Ries, L.A. Pruitt, J. Bone Joint Surg. 86A, 1271 (2004)
  • [16] J. Furmanski, S. Gupta, A. Chawan, A. Kohm, J. Lannutti, B. Jewett, L.A. Pruitt, M.D. Ries, J. Bone Joint Surg. 89, 2266 (2007)
  • [17] ISO 7206-2:2011, Implants for surgery - Partial and total hip joint prostheses, Part 2: Articulating surfaces made of metallic, ceramic and plastics materials
  • [18] ISO 21535:2001, Non-active surgical implants - Joint replacement implants - Specific requirements for hip-joint replacement implants
  • [19] Y. Yan, A. Neville, D. Dowson, S. Williams, J. Fisher, Wear 267, 683 (2009)
  • [20] Z.M. Jin, M. Stone, E. Ingham, J. Fisher, Current Orthopaedics 20, 32 (2006)

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.bwnjournal-article-appv123n2097kz
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.