Radiation sensing MOSFETs have found numerous applications as detectors or device components in radiation fields used in nuclear industry, medical applications and space research. Monte Carlo simulations of MOSFET energy response to X-ray and gamma radiation for different packaging were performed. The photon transport Monte Carlo software FOTELP-2K10 has been adapted to obtain the energy deposited in MOSFET structure with microscopic dimensions. In this work the ratio between values of total energy deposited in the sensitive volume (thick SiO_2 layer) for cases of MOSFET structure with and without package lid is presented. For this purpose is defined the shielding energy dependence factor (SDEF), and gave its value for kovar and Ti-24Al-11Nb and Ti-13Nb-13Zr alloys as lid materials.
Discipline
Journal
Year
Volume
Issue
Pages
655-658
Physical description
Dates
published
2012-10
received
2011-09-05
(unknown)
2012-07-03
Contributors
author
- Vinča Institute of Nuclear Sciences, Belgrade, Serbia
author
- Vinča Institute of Nuclear Sciences, Belgrade, Serbia
author
- Vinča Institute of Nuclear Sciences, Belgrade, Serbia
author
- Institute for Testing Materials-IMS, Belgrade, Serbia
author
- Faculty of Technology and Metallurgy, University of Belgrade, Belgrade, Serbia
References
- [1] A. Holmes-Siedle, Nucl. Instrum. Methods 121, 169 (1974)
- [2] A.B. Rosenfeld, M.I. Reinhard, D. Marinaro, P. Ihnat, G. Taylor, L. Peak, N. Freeman, D. Alexiev, M. Lerch, IEEE Trans. Nuclear Sci. 46, 1766 (1999)
- [3] G.J. Brucker, S. Kronenberg, F. Gentner, IEEE Trans. Nucl. Sci. 42, 33 (1995)
- [4] Z. Savic, M. Kovačević, M. Petrović, Radiat. Protect. Dosim. 64, 205 (1996)
- [5] T. Kron, L. Duggan, A. Rosenfeld, T. Smith, M. Butson, G. Kaplan, S. Howlet, K. Hyodo, Phys. Med. Biol. 43, 3235 (1998)
- [6] M.A.R. Othman, D.L. Cutajar, N. Hardcastle, S. Guatelli, A.B. Rosenfeld, Radiat. Prot. Dosim. 141, 10 (2010)
- [7] FOTELP-2K6, Photons, Electrons and Positrons Transport in 3D by Monte Carlo Techniques, IAEA-1388, http://www.nea.fr/tools/abstract/detail/iaea1388
- [8] FOTELP-2K10, http://www.vinca.rs/%7Erasa/doc/FOTPEN10.PDF
- [9] S.J. Stanković, R.D. Ilić, P. Osmokrović, B. Lončar, A. Vasić, IEEE Trans. Plasma Sci. 34, 1715 (2006)
- [10] E.A. Siegbahn, E. Bräuer-Krisch, A. Bravin, H. Nettelbeck, M.L.F. Lerch, A.B. Rosenfeld, Med. Phys. 36, 1128 (2009)
- [11] S.J. Stanković, R.D. Ilić, M. Petrović, B. Lončar, A. Vasić, Mater. Sci. Forum 518, 361 (2006)
- [12] S.J. Stanković, M. Petrović, M. Kovačević, A. Vasić, P. Osmokrović, B. Lončar, Mater. Sci. Forum 555, 141 (2007)
- [13] S.J. Stanković, R.D. Ilic, D.M. Davidovic, M. Petrovic, Acta Phys. Pol. A 115, 816 (2009)
- [14] S.J. Stanković, R.D. Ilic, K.S. Jankovic, A Vasic-Milovanovic, B. Loncar, Acta Phys. Pol. A 120, 252 (2011)
- [15] XCOM: Photon Cross Sections Database, 2010, http://physics.nist.gov/PhysRefData/Xcom/html/xcom1.html