Opto-Magnetic Method for Epstein - Barr Virus and Cytomegalovirus Detection in Blood Plasma Samples

Content

Title variants

Languages of publication

EN

Abstracts

EN
Motivated by characterization of paramagnetic materials (Al, Mn and Ti) and diamagnetic materials (Cu, C and Zn) by opto-magnetic method that is based on light-matter interaction using digital imaging, we present results of Epstein-Barr virus (EBV) and cytomegalovirus (CMV) detection in blood plasma. To investigate light-blood plasma interaction we use wavelength difference of diffuse white light and reflected polarized light in red and blue channels of digital images (opto-magnetic method). Digital images of samples are analyzed by spectral convolution algorithm for light-matter interaction analysis. Since opto-magnetic method can detect very small difference between normal and pathological tissue states it is advantageous in comparison with classical methods. Especially it is important for early detection of suspicious tissue states and detection of viral infection presence in plasma. We compared our results with results of standard biomedical test for EBV and CVM, as a reference, and found out for group of 40 samples significant correlation of 93. 6%.

Keywords

Contributors

  • Clinic for Gynecology and Obstetrics "Narodni front", Kraljice Natalije 62, 11000 Belgrade, Serbia
author
  • Department for Biomedical Engineering, Faculty of Mechanical Engineering, University of Belgrade, Kraljice Marije 16, 11120 Belgrade 35, Serbia
author
  • Department for Biomedical Engineering, Faculty of Mechanical Engineering, University of Belgrade, Kraljice Marije 16, 11120 Belgrade 35, Serbia

References

  • 1. M.L. Gulley, J. Mol. Diagn. 3, 1 (2001)
  • 2. S. Tsuchiya, Crit. Rev. Oncol. Hematol. 44, 227 (2002)
  • 3. M.P. Thompson, R. Kurzrock, Clin. Cancer. Res. 10, 803 (2004)
  • 4. S.L. Young, A.B. Rickinson, Cancer 4, 757 (2004)
  • 5. R.F. Ambinder, R.B. Mann, Am. J. Pathol. 145, 239 (1994)
  • 6. S.A.S. Staras, S.C. Dollard, K.W. Radford, W.D. Flanders, R.F. Pass, M.J. Cannon, Clin. Infect. Dis. 43, 1143 (2006)
  • 7. P.J. Lambert, A.G. Whitman, O.F. Dyson, S.M. Akula, Virology J 3, 51 (2006)
  • 8. H. Ong, V. Chandran, J. Clin. Virol. 34, 195 (2005)
  • 9. L.L. Decker, L.D. Klaman, D.A. Thorley-Lawson, J. Virol. 70, 3286 (1996)
  • 10. R. Hassan, L.R. White, C.G. Stefanoff, D.E. de Oliveira, F.E. Felisbino, C.E. Klumb, C.E. Bacchi, H.N. Seuanez, I.R. Zalcberg, Diagn. Pathol. 1, 17 (2006)
  • 11. C.C. Huang, C.H. Su, M.Y. Liao, C.S. Yeh, Phys. Chem. Chem. Phys. 11 6331 (2009)
  • 12. M. Bhavnani, R.B. McGucken, J. Craske, J. Clin. Pathol. 44, 351 (1991)
  • 13. B. Weber, M. Brunner, W. Preiser, H.W. Doerr, J. Virol. Methods. 57, 87 (1996)
  • 14. J. Bandic, Dj. Koruga, R. Mehendale, S. Marinkovich: System, device and method for dermal imaging, US Pat. App. No. PCT/US2008/050438, Publication No: WO/2008/086311, Publication Date: 2008-07-17
  • 15. Dj. Koruga, A. Tomic, Z. Ratkaj, L. Matija, Mat. Sci. For. 518, 491 (2006)
  • 16. Dj. Koruga, A. Tomic: Method and algorithm for analysis of light-matter interaction based on spectral convolution, US Pat. App. No. 61/061, 852, 2008, PCT/US2009/030347, Publ. No: WO/2009/089292, Publ. Date: 2009-07-16
  • 17. G. Saxby, Practical Holography, 3rd ed., IOP Publishing Ltd., CRC Press, UK, 2004, p. 255
  • 18. R. Baer, A.T. Bankier, M.D. Biggin, P.L. Deininger, P.J. Farrell, T.J. Gibson, G. Hatfull, G.S. Hudson, S.C. Satchwell, C. Séguin, P.S. Tuffnell, B.G. Barrell, Nature 310, 207 (1984)

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.bwnjournal-article-appv117n513kz
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.