Full-text resources of PSJD and other databases are now available in the new Library of Science.
Visit https://bibliotekanauki.pl

PL EN


Preferences help
enabled [disable] Abstract
Number of results
2002 | 101 | 1 | 147-158

Article title

Measurement, Modeling and Improvement of Optical Image Quality in Human Eyes

Authors

Content

Title variants

Languages of publication

EN

Abstracts

EN
New objective methods to measure the optical aberrations of the eye are reviewed, in particular the probably more representative ones: Hartmann-Shack wavefront sensor and laser ray tracing. They are shown to be robust and provide highly reliable data, which are permitting to obtain many new results about the optics of the eye in basic and clinical studies. In addition, different experiments have demonstrated the correction of eye's aberration. Again two representative approaches are reviewed. The first results were obtained with the close-loop adaptive optics system developed at the University of Rochester. Later on, phase plates made by photosculpture in photoresist (placed in front of the eye like conventional lenses) have also permitted the correction of ocular aberrations. This is a new, but already very active field of research, which has open many new questions and a wide variety of applications.

Keywords

EN

Contributors

author
  • Instituto de Optica "Daza de Valdés", Consejo Superior de Investigaciones Cientìficas (CSIC), Serrano 121, 28006 Madrid, Spain

References

  • 1. H.C. Howland, B. Howland, J. Opt. Soc. Am. A, 67, 1508, 1977
  • 2. J. Liang, B. Grimm, S. Goelz, J. Bille, J. Opt. Soc. Am. A, 11, 1949, 1994
  • 3. R. Navarro, M.A. Losada, Optom. Vision Sci., 74, 540, 1997
  • 4. P. Mierdel, H.E. Krinke, W. Wiegand, M. Kaemmerer, T. Seiler, Ophthalmologe, 94, 441, 1997
  • 5. J.C. He, S. Marcos, R.H. Webb, S.A. Burns, J. Opt. Soc. Am. A, 15, 2449, 1998
  • 6. T. Oshika, S.D. Klyce, R.A. Applegate, H.C. Howland, M.A. El Danasoury, Am. J. Ophthalmol., 127, 1, 1999
  • 7. T. Seiler, M. Kaemmerer, P. Mierdel, H.-E. Krinke, Arch. Ophthalmol., 118, 17, 2000
  • 8. E. Moreno-Barriuso, J. Merayo-Lloves, S. Marcos, R. Navarro, L. Llorente, S. Barbero, Invest. Ophthalmol. Vis. Sci., 42, 1396, 2001
  • 9. J. Liang, D.R. Williams, D.T. Miller, J. Opt. Soc. Am. A, 14, 2884, 1997
  • 10. R. Navarro, E. Moreno-Barriuso, S. Bará, T. Mancebo, Opt. Lett., 25, 236, 2000
  • 11. M.S. Smirnov, Biofizika, 6, 687, 1961
  • 12. G. Walsh, W.N. Charman, H.C. Howland, J. Opt. Soc. Am. A, 1, 987, 1984
  • 13. E. Moreno-Barriuso, R. Navarro, J. Opt. Soc. Am. A, 17, 974, 2000
  • 14. D. Malacara, Optical Shop Testing, 2nd Ed., John Wiley Sons, New York 1992
  • 15. J. Porter, A. Guirao, I.G. Cox, D.R. Williams, J. Opt. Soc. Am. A, 18, 1793, 2001
  • 16. R. Navarro, E. Moreno, C. Dorronsoro, J. Opt. Soc. Am. A, 15, 2522, 1998
  • 17. I. Escudero-Sanz, R. Navarro, J. Opt. Soc. Am. A, 16, 1, 1999
  • 18. A. Roorda, D.R. Williams, Nature, 397, 520, 1999
  • 19. H. Hofer, L. Chen, G.Y. Yoon, B. Singer, Y. Yamauchi, D.R. Williams, Optics Express, 8, 631, 2001
  • 20. S. Bará, T. Mancebo, E. Moreno-Barriuso, Appl. Opt., 39, 3413, 2000

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.bwnjournal-article-appv101n111kz
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.