Polyvinylpyrrolidone-Based Coatings for Polyurethanes – The Effect of Reagent Concentration on Their Chosen Physical Properties

Content

Title variants

Languages of publication

EN

Abstracts

EN
A method of manufacturing hydrogel coatings designed to increase the hydrophilicity of polyurethanes (PU) is presented. Coatings were obtained from polyvinylpyrrolidone (PVP) by free radical polymerisation. The authors proposed a mechanism of a two-step grafting - crosslinking process and investigated the influence of reagent concentration on the coating’s physical properties - hydrogel ratio (HG) and equilibrium swelling ratio (ESR). A surface analysis of freeze-dried coatings using scanning electron microscopy (SEM) showed a highly porous structure. The presented technology can be used to produce biocompatible surfaces with limited protein and cell adhesive properties and can be applied in fabrication of number of biomedical devices, e.g. catheters, vascular grafts and heart prosthesis.

Publisher

Year

Volume

33

Issue

4

Pages

563-571

Physical description

Dates

published
1 - 12 - 2012
online
28 - 12 - 2012

Contributors

author
  • Warsaw University of Technology, Faculty of Chemical and Process Engineering, Department of Biotechnology and Bioprocess Engineering, Waryńskiego 1, 00-645 Warszawa, Poland
  • Warsaw University of Technology, Faculty of Chemical and Process Engineering, Department of Biotechnology and Bioprocess Engineering, Waryńskiego 1, 00-645 Warszawa, Poland
author
  • Warsaw University of Technology, Faculty of Chemical and Process Engineering, Department of Biotechnology and Bioprocess Engineering, Waryńskiego 1, 00-645 Warszawa, Poland

References

  • Butruk B., Trzaskowski M., Ciach T., 2012. Fabrication of biocompatible hydrogel coatings for implantable medical devices using Fenton-type reaction. Mat. Sci. Eng.: C., 32, 1601-1609. DOI: 10.1016/j.msec.2012.04.050.[Crossref][WoS]
  • Kaźmierska K., Szwast M., Ciach T., 2010. Determination of urethral catheter surface lubricity. J. Mater. Sci. Mater., 19, 2301-2306. DOI: 10.1007/s10856-007-3339-4.[Crossref]
  • Kim J.H., Kim S.C., 2002. PEO-grafting on PU/PS for enhanced blond compatibility - effect of pendant length and grafting density. Biomater., 23, 2015-2025. DOI: 10.1016/S0142-9612(01)00330-1.[Crossref]
  • Le Y., Scott M., 2010. Immunocamouflage: The biophysical basis of immunoprotection by grafted methoxypoly(ethylene glycol) (mPEG). Acta Biomater., 6, 2631-2641. DOI: 10.1016/j.actbio.2010.01.031.[WoS][Crossref][PubMed]
  • Patel A, Mequanint K., 2007. Novel physically crosslinked polyurethane-block-poly(vinyl pyrrolidone) hydrogel biomaterials. Macromol. Biosci., 7, 727-737. DOI: 10.1002/mabi.200600272.[WoS][Crossref][PubMed]
  • Paradowska A.E., Kaźmierska K.A., Ciach T., 2010. Influence of the coating process parameters on the quality of PUR/PVP hydrogel coatings for PVC medical devices. Pol. J. Chem. Technol., 12, 38-45. DOI: 10.2478/v10026-010-0016-z.[Crossref]
  • Walling C., El-Taliawi G.M., Johnson R.A., 1974. Fenton's reagent. IV. Structure and reactivity relations in the reactions of hydroxyl radicals and the redox reactions of radicals, J. Am. Chem. Soc., 96, 133-139. DOI: 10.1021/ja00808a022.[Crossref]
  • Xu L., Siedlecki C.A., 2007. Effects of surface wettability and contact time on protein adhesion to biomaterial, Biomater., 28, 3273-3283. DOI: 10.1016/j.biomaterials.2007.03.032.[PubMed][Crossref]
  • ---

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.-psjd-doi-10_2478_v10176-012-0046-6
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.