PL EN


Preferences help
enabled [disable] Abstract
Number of results
2008 | 14 | 3 | 151-162
Article title

IMRT versus 3D-CRT for thyroid cancer

Content
Title variants
Languages of publication
EN
Abstracts
EN
A 3D-CRT involving a 4-field (5-field, 6-field, etc.) technique (photon and electron beams) and an alternative IMRT 7-field technique with 6 MV photon fields for thyroid cancer were compared. The IMRT allows reduction in the dose to the spinal cord of about 12 Gy and permits better coverage of the target volume with smaller standard deviation (average 4.65% for 3D-CRT as compared with 1.81% for IMRT). The time needed to prepare therapy (TPS, dosimetry, preparing boluses and electron aperture) and the session time are about the same for both techniques.
Publisher
Year
Volume
14
Issue
3
Pages
151-162
Physical description
Dates
published
1 - 1 - 2008
online
14 - 4 - 2009
References
  • Karczmarzyk R, Dabrowski R. [Rules of defining dose in irradiated volume in thyroid cancer external photon and electron beams radiotherapy]. Nowotwory J Oncol. 1994; 44: 349-355. Polish.
  • Miften MM, Das SK, Su M, Marks LB. A dose-volume-based tool for evaluating and ranking IMRT treatment plans. J Appl Clin Med Phys. 2004; 5(4): 1-14.[Crossref][PubMed]
  • Knoos T, Kristensen I, Nilsson P. Volumetric and dosimetric evaluation of radiation treatment plans: Radiation conformity index. Int J Radiat Oncol Biol Phys. 1998; 42(5): 1169-1176.[PubMed][Crossref]
  • Gizynska MK, Chelminski K, Zawadzka A, Bulski W. A Tool for Comparing Dose Distribution in 3D and IMRT Plans. Pol J of Environ Stud. 2006; 15(4A): 174-176.