Saturation thickness for multiple scattering gamma rays from multiple sources has been measured experimentally and simulated using the Monte Carlo N-Particle (MCNP) Code. Experimental measurements were performed using a collimated beam of gamma-rays from 57Co, 203Hg, 133Ba, 22Na, 137Cs, 65Zn and 60Co sources. The gamma rays were directed at rectangular aluminium targets of varying thickness. A NaI (Tl) scintillation detector placed at a backscattering angle of 180° was used to detect the scattered photons. The measured and calculated saturation thickness increases with increasing energy of incident gamma-rays. Experimental and simulated values are compared and are in good agreement.

Publisher

Journal

Year

Volume

12

Issue

11

Pages

792-798

Physical description

Dates

published
1 - 11 - 2014
online
17 - 8 - 2014

Contributors

  • Government Science College Hassan, Hassan, 573 201, Karnataka, India
author
  • Government Science College Hassan, Hassan, 573 201, Karnataka, India
  • St Aloysius College (Autonomous), Mangalore, 575 003, Karnataka, India
  • Mangalore University, Mangalagangothri, 574 199, India

References

  • [1] E. Hayward, J. Hubbell, J. Appl. Phys., 25, 506 (1954) http://dx.doi.org/10.1063/1.1721671[Crossref]
  • [2] D. B. Pozdneyev, J. Nucl. Energy, 21, 197 (1967) http://dx.doi.org/10.1016/0022-3107(67)90129-3[Crossref]
  • [3] A. K. Sinha, A. Bhattacharjee, Pramana, 33, 493 (1989) http://dx.doi.org/10.1007/BF02846016[Crossref]
  • [4] L. Paramesh, P. Venkataramaih, K. Gopala, H. Sanjeevaih, Nucl. Instruments Methods, 206, 327 (1983) http://dx.doi.org/10.1016/0167-5087(83)91277-2[Crossref]
  • [5] T. Pitkanen, T D. Laundy, R. S. Holt, M. J. Cooper, Nucl. Instruments Methods, 251, 536 (1986). http://dx.doi.org/10.1016/0168-9002(86)90649-2[Crossref]
  • [6] M. Singh, G. Singh, B. Singh, B. S. Sandhu, Radiat. Phys. Chem., 77, 991 (2008)
  • [7] K. U. Kiran, K. Ravindraswami, K. M. Eshwarappa, H. M. Somashekarappa, Radiat. Phys. Chem., 97, 107 (2014)
  • [8] T. Pitkanen, M. J. Cooper, D. Laundry, R. S. Holt, Nucl. Instuments Methods Phys. Res. A, 1987, 257, 384 (1987)
  • [9] A. D. Sabharwal, M. Singh, B. Singh, B. S. Sandhu, Appl. Radiat. Isot., 66, 1467 (2008) http://dx.doi.org/10.1016/j.apradiso.2008.03.006[Crossref]
  • [10] M. J. Berger, J. H. Hubbell, XCOM: photon crosssections on a personal computer, 1987, NBSIR-87, 3597 (1987)
  • [11] C. E. Crouthamel, Applied Gamma Ray Spectrometry, Second edition, (Pergamon Press, Oxford, 1970)
  • [12] Manpreeth Singh, Gurvinderjit Singh, B. S. Sandhu, Bhajan Singh, Radiat. Meas., 42, 420 (2007) http://dx.doi.org/10.1016/j.radmeas.2007.01.037[Crossref]
  • [13] Manpreeth Singh, Gurvinderjit Singh, B. S. Sandhu, Bhajan Singh, Appl. Radiat. Isot., 64, 373 (2006) http://dx.doi.org/10.1016/j.apradiso.2005.08.015[Crossref]
  • [14] Gurvinderjit Singh, Manpreet Singh, B. S. Sandhu, Bhajan Singh, Appl. Radiat. Isot., 66, 1151 (2008) http://dx.doi.org/10.1016/j.apradiso.2008.01.007[Crossref]
  • [15] J. F. Briesmeister, MCNP a general purpose Monte Carlo N-Particle transport code, Version 4A, Los Alamos National Laboratory report, LA-12625 (1993)

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.-psjd-doi-10_2478_s11534-014-0516-1
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.