Article title

Simulation on the response of new phosphate glass RPC for γ-rays and e+/e− particles using GEANT3

Content

Title variants

Languages of publication

EN

Abstracts

EN
The influence of phosphate glass electrode in the configuration of resistive plate chamber has been studied using GEANT3.21 Monte Carlo code. Bakelite electrodes were replaced by phosphate glass electrodes, as these glass materials have low bulk resistivity, are portable and easy to handle. These types of RPCs in their compact form of all materials are suitable for high rate background environment. We find that these new types of RPCs give little higher response to γ-rays and e+/e− particles, both for single-and double gap RPCs. The results of simulation are discussed.

Publisher

Journal

Year

Volume

6

Issue

3

Pages

524-529

Physical description

Dates

published
1 - 9 - 2008
online
17 - 7 - 2008

Contributors

author
  • IAP, High Energy Physics Lab: Department of Physics, Konkuk University, Seoul, 143-701, Korea
author
  • Liquid Crystal Research Center, Konkuk University, Seoul, 143-701, Korea

References

  • [1] P. Fonte, IEEE T. Nucl. Sci. 49, 3 (2002) http://dx.doi.org/10.1109/TNS.2002.998672[Crossref]
  • [2] S.P. Ratti, C.S. Lim, T. Yamanaka (Ed.), Proc. Int. Conf. on High Energy Physics (ICHEP2000), (World Scientific, Singapore, 2000) 1261
  • [3] CMS-The Muon Project, Technical Design Report, CERN, Geneva, (CERN/LHCC 1997) 97
  • [4] G. Carboni at al., Nucl. Instrum. Meth. A 533, 107 (2004) http://dx.doi.org/10.1016/j.nima.2004.07.010[Crossref]
  • [5] L. Lopes et al., Nucl. Instrum. Meth. A 533, 121 (2004) http://dx.doi.org/10.1016/j.nima.2004.07.013[Crossref]
  • [6] J. Zhang et al., Nucl. Instrum. Meth. A 540, 102 (2005) http://dx.doi.org/10.1016/j.nima.2004.10.037[Crossref]
  • [7] M. Abbrescia et al., Nucl. Instrum. Meth. A 394, 13 (1997) http://dx.doi.org/10.1016/S0168-9002(97)00597-4[Crossref]
  • [8] J. Zhang et al., Nucl. Instrum. Meth. A 580,1250 (2007) http://dx.doi.org/10.1016/j.nima.2007.07.009[Crossref]
  • [9] C. Gustavino et al., Nucl. Instrum. Meth. A 457, 558 (2001) http://dx.doi.org/10.1016/S0168-9002(00)00777-4[Crossref]
  • [10] GEANT-Detector Description and Simulation Tool, CERN Program Library, Geneva, Switzerland, (Long Write-up W5013 October 94)
  • [11] A. Akindinov et al., Nucl. Instrum. Meth. A 572, 676 (2007) http://dx.doi.org/10.1016/j.nima.2006.12.027[Crossref]
  • [12] J.T. Rhee et al., Phys. Scr. 75, 103 (2007) http://dx.doi.org/10.1088/0031-8949/75/1/017[Crossref]
  • [13] S. Altieri et al., Nucl. Instrum. Meth. A 461, 57 (2001) http://dx.doi.org/10.1016/S0168-9002(00)01160-8[Crossref]
  • [14] J. T. Rhee et al., Rev. Sci. Instrum. 76, 073301 (2005) http://dx.doi.org/10.1063/1.1927091[Crossref]
  • [15] B. Hong et al., J. Korean Phys. Soc. 45, 1490 (2004)
  • [16] C. Lippmann et al., Nucl. Instrum. Meth. A 533, 11 (2004) http://dx.doi.org/10.1016/j.nima.2004.06.120[Crossref]
  • [17] M. Jamil et al., “A Simulation studies of low resistive phosphate glass electrode RPC e+/e− sensitivity using GEANT MC” (Unpublished)
  • [18] S. Altieri et al., Nucl. Instrum. Meth. A 456, 99 (2000) http://dx.doi.org/10.1016/S0168-9002(00)00971-2[Crossref]
  • [19] M. Abbrescia at al., Nucl. Instrum. Meth. A 506, 101 (2003) http://dx.doi.org/10.1016/S0168-9002(03)01378-0[Crossref]

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.-psjd-doi-10_2478_s11534-008-0075-4
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.