Journal
Article title
Title variants
Languages of publication
Abstracts
Rutin is a flavonoid commonly employed for many therapeutic purposes. Although the electroactive phenolic groups of rutin might be oxidized at low applied potential, the adsorption of oxidized species changes the electrode surface. As a consequence, the repeatability and reproducibility of the method decreases, which limits electroanalytical applications. This paper describes the use of disposable screen-printed electrodes as an alternative to improve the electrochemical quantification of rutin in commercial and standard samples. The electrochemical behavior was consistent to what is observed using other carbon electrodes: an adsorption-involved step and a pH-dependent oxidation process. The replacement of the electrodes between the analyses ensured rapid analysis, good intermediate precision and repeatability. The proposed method was successfully applied to rutin determination in pharmaceutical samples of capsules, with the limit of quantification being 0.30 µM. [...]
Journal
Year
Volume
Issue
Pages
1609-1616
Physical description
Dates
published
1 - 10 - 2012
online
21 - 7 - 2012
Contributors
author
- Faculty of Pharmacy, Federal University of Goias, Goiânia-GO, 74.605-220, Brazil
author
- Faculty of Pharmacy, Federal University of Goias, Goiânia-GO, 74.605-220, Brazil
author
- Faculty of Pharmacy, Federal University of Goias, Goiânia-GO, 74.605-220, Brazil
author
- Faculty of Pharmacy, Federal University of Goias, Goiânia-GO, 74.605-220, Brazil
author
- Faculty of Pharmacy, Federal University of Goias, Goiânia-GO, 74.605-220, Brazil
author
- Faculty of Pharmacy, Federal University of Goias, Goiânia-GO, 74.605-220, Brazil, ericsgil@gmail.com
References
- [1] J. Yang, J. Guo, J. Yuan, LWT-Food Sci. Technol. 41, 1060 (2008) http://dx.doi.org/10.1016/j.lwt.2007.06.010[Crossref]
- [2] A.R. Malagutti, V.G. Zuin, E.T.G. Cavalheiro, L.H. Mazo, Electroanal. 18, 1028 (2006) http://dx.doi.org/10.1002/elan.200603496[Crossref]
- [3] M.E. Ghica, A.M.O. Brett, Electroanal. 17, 331 (2005) http://dx.doi.org/10.1002/elan.200403100[Crossref]
- [4] W.Y. Su, S.H. Cheng, Electroanal. 22, 707 (2010) http://dx.doi.org/10.1002/elan.200900455[Crossref]
- [5] A.C. Franzoi, A. Spinelli, I.C. Vieira, J. Pharm. Biomed. Anal. 47, 973 (2008) http://dx.doi.org/10.1016/j.jpba.2008.03.031[Crossref]
- [6] J.B. He, Y. Wang, N. Deng, Z.G. Zha, X. Lin, Electrochim. Acta. 52, 6665 (2007) http://dx.doi.org/10.1016/j.electacta.2007.04.075[Crossref]
- [7] K. Tyszczuk, J. Pharm. Biomed. Anal. 49, 558 (2009) http://dx.doi.org/10.1016/j.jpba.2008.11.022[Crossref]
- [8] Y. Wang, H. Xiong, X. Zhang, S. Wang, Microchim. Acta 170, 27 (2010) http://dx.doi.org/10.1007/s00604-010-0380-7[Crossref]
- [9] A.C. Oliveira, L.H. Mascaro, Curr. Anal. Chem. 7, 101 (2011)
- [10] S. Yang, L. Qu, G. Li, C. Liu, J. Electroanal. Chem. 645, 115 (2010) http://dx.doi.org/10.1016/j.jelechem.2010.04.019[Crossref]
- [11] R. Behzad, M. Najmeh, A.E. Ali, K.M. Hassan, Anal. Method. 3, 2510 (2011) http://dx.doi.org/10.1039/c1ay05271c[Crossref]
- [12] A.C. Franzoi, R.A. Peralta, A. Neves, I.C. Vieira, Talanta 78, 221 (2009) http://dx.doi.org/10.1016/j.talanta.2008.11.007[Crossref]
- [13] G.S. Garbellini, G.R. Salazar-Banda, L.A. Avanca, Quim. Nova. 31, 123 (2008) http://dx.doi.org/10.1590/S0100-40422008000100024[Crossref]
- [14] A.J. Saterlay, R.G. Compton, Fresenius J. Anal. Chem. 367, 308 (2000) http://dx.doi.org/10.1007/s002160000412[Crossref]
- [15] E.S. Gil (org), Controle de Qualidade de Medicamentos, 3rd edition (Pharmabooks, São Paulo, 2011) (In Portuguese)
- [16] O.D. Renedo, M.A. Alonso-Lomillo, M.J. Martínez, Talanta 73, 202 (2007) http://dx.doi.org/10.1016/j.talanta.2007.03.050[Crossref]
- [17] P. Fanjul-Bolado, P. Queipo, P.J. Lamas-Ardisana, A. Costa-García, Talanta 74, 427 (2007) http://dx.doi.org/10.1016/j.talanta.2007.07.035[Crossref]
- [18] M.F. Bergamini, A.L. Santos, N.R. Stradiotto, M.V.B. Zanoni, J. Pharm. Biomed. Anal. 43, 315 (2007) http://dx.doi.org/10.1016/j.jpba.2006.06.001[Crossref]
- [19] Y. Shih, J.M. Zen, H.H. Yang, J. Pharm. Biomed. Anal. 29, 827 (2002) http://dx.doi.org/10.1016/S0731-7085(02)00179-6[Crossref]
- [20] A.G. Crevillén, M. Pumera, M.C. González, A. Escarpa, Electrophoresis. 29, 2997 (2008) http://dx.doi.org/10.1002/elps.200700947[Crossref]
- [21] E. Bodoki, S. Laschi, I. Palchetti, R. Sandulescu, M. Mascini, Talanta 76, 288 (2008) http://dx.doi.org/10.1016/j.talanta.2008.02.048[Crossref]
- [22] D.D. Perrin, B. Dempsey, Buffers for pH and Metal Ion Control (Chapman and Hall Laboratory Manuals, London, 1974)
- [23] Association of Official Chemists, Official Methods of Analysis of AOAC International, 16th edition (AOAC International Official Methods, Arlington, 1995) 29
Document Type
Publication order reference
Identifiers
YADDA identifier
bwmeta1.element.-psjd-doi-10_2478_s11532-012-0093-3